• 제목/요약/키워드: Acoustic Power Spectrum

검색결과 120건 처리시간 0.024초

성악도의 두성구와 흉성구 발성에 대한 음향학적 분석 (Acoustic Analysis of Singing Voice)

  • 진성민
    • 대한후두음성언어의학회지
    • /
    • 제13권1호
    • /
    • pp.52-58
    • /
    • 2002
  • The pitch range of the human voice is variable, extending from chest register to falsetto. Although numerous studies have investigated after laryngeal mechanism description of registers, systematic and objective studies were lack. The purpose of this study was to analyze and compare head register with chest register of singers acoustically. Fifteen healthy tenor major students were selected. Fifteen healthy untrained adults were the control group for this study. Long term average(LTA) power spectrum using the Fast Fourier transform(FFT) algorithm and Linear predictive coding (LPC) filter response were made during /a/ sustained in both head(G4, 392Hz) md chest registers (C3, 131Hz). Statistical analysis was performed using Mann-Whitney test. In the LTA power spectrum, head register of singer has increased level(energy gain) in the frequency band of 2.2-3.4kHz(p<0.01), and 7.5-8.4kHz(p<0.01, p<0.05). Chest register of singer has increased level in the frequency band of 2.2-3.1kHz(p<0.01), 7.8-8.4kHz(p<0.05) and around 9.6kHz(p<0.01). LTA power spectrum reveals a peak of acoustic energy around 2500Hz known as the singer's formant and another peak of acoustic energy around 8000Hz in singer's voice.

  • PDF

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.

음향방출법에 의한 발전용 밸브 누설평가 (The Evaluation of Internal Leak in Valve for Power Plant Using Acoustic Emission Method)

  • 이상국;이선기;이준신;이욱륜
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1733-1739
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

음향방출법에 의한 원자력발전소 밸브내부 누설평가에 관한 연구 (A Study on the Evaluation of Internal Leak in Valve for Nuclear Power Plant Using Acoustic Emission Method)

  • 이상국;이선기;이준신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.284-289
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

설정 음압 및 스펙트럼 재현을 위한 음향 환경 시험 챔버의 기본 설계 변수 선정 (Design of High Intensity Acoustic Test Facility to Generate Required Sound Pressure Level and Spectrum)

  • 김영기;우성현;김홍배;문상무;이상설
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.867-872
    • /
    • 2002
  • A high intensity acoustic test facility is constructed at Korea Aerospace Research Institute (KARI) by 2003. The reverberant chamber of the facility has a volume of 1,228 cubic meters and shall provide an acoustic environment of 152 dB over the frequency range of 25 Hz to 10,000 Hz. The facility consists of a large scaled reverberant chamber, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of a chamber and power generation systems are controlled to meet the requirement of the test. The volume of a reverberant chamber is controlled by the size of test objects and the reverberant characteristics of a chamber. The capacity of acoustic power generation systems is determined by the energy absorption of a chamber and the efficiency of acoustic modulators. Simple math is employed to calculate the required power of acoustic modulators. Moreover, the paper explains how the distribution of sound pressure level at low frequency is checked by analytical and numerical methods.

  • PDF

Long Term Average Spectrum Characteristics of Head and Chest Register Sounds of Western Operatic Singers - Possibility of a Second Singer's Formant-

  • Jin, Sung-Min;Kwon, Young-Kyung;Song, Yun-Kyung
    • 음성과학
    • /
    • 제10권2호
    • /
    • pp.99-109
    • /
    • 2003
  • The purpose of this study was to analyze and compare head register with chest register of singers acoustically. Fifteen healthy tenor major students were participated. Fifteen healthy untrained adults were chosen as the control group for this study. Long term average (LTA) power spectrum using the Fast Fourier transform (FFT) algorithm and Linear predictive coding (LPC) filter response were made with /a/ sustained in both head (G4, 392 Hz) and chest registers (C3, 131 Hz). Statistical analysis was performed using the Mann-Whitney test. In the LTA power spectrum, head register of singers increased in the level of energy gain within the frequency of 2.2-3.4 kHz (p<0.01), and 7.5-8.4 kHz (p<0.01, p<0.05). Chest register of singers increased in the frequency of 2.2-3.1 kHz (p<0.01), 7.8-8.4 kHz (p<0.05) and around 9.6 kHz (p<0.01). The LTA power spectrum revealed a peak of acoustic energy around 2,500 Hz, known as the singer's formant and another peak of acoustic energy around 8,000 Hz in the singer's voice.

  • PDF

유입 난류에 의한 에어포일 캐스케이드 광대역 소음장의 고주파 근사 예측식의 개발 (High-frequency Approximate Formulation for the Prediction of Broadband Noise of Airfoil Cascades with Inflow Turbulence)

  • 정성수;정완섭;이수갑;정철웅
    • 한국소음진동공학회논문집
    • /
    • 제15권10호
    • /
    • pp.1177-1185
    • /
    • 2005
  • This paper investigates the noise radiated by a cascade of flat-plate airfoils interacting with homogeneous, isotropic turbulence. At frequencies above the critical frequency, all wavenumber components of turbulence excite propagating cascade modes, and cascade effects are shown to be relatively weak. In this frequency range, acoustic power was shown to be approximately proportional to the number of blades. Based on this finding at high frequencies, an approximate expression is derived for the power spectrum that is valid above the critical frequency and which is in excellent agreement with the exact expression for the broadband power spectrum. The approximate expression shows explicitly that the acoustic Power above the critical frequency is proportional to the blade number, independent of the solidity, and varies with frequency as ${\phi}_{ww}(\omega/W$), where ${\phi}_{ww}$ is the wavenumber spectrum of the turbulence velocity and W is mean-flow speed. The formulation is used to perform a parametric study on the effects on the power spectrum of the blade number stagger angle, gap-chord ratio and Mach number. The theory is also shown to provide a close fit to the measured spectrum of rotor-stator interaction when the mean square turbulence velocity and length-scale are chosen appropriately.

평균 응력을 고려한 음향 하중을 받는 항공기 센서 포드 외피 구조의 내구 수명 분석 (Fatigue Life Prediction for the Skin Structures of Aircraft Sensor Pod Under Acoustic Load with Mean Stress)

  • 전민혁;김연주;조현준;이미연;김인걸;이한솔;조재명;배종인;박기영
    • 한국군사과학기술학회지
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2023
  • The skin structure of sensor pod mounted on the exterior of aircraft can be exposed to the acoustic dynamic load and static load such as aerodynamic pressure and inertial load during flight. Fatigue life prediction of structural model under acoustic load should be performed and also differential stiffness of model modified by static load should be considered. The acoustic noise test spectrum of MIL-STD-810G was applied to the structural model and the stress response power spectral density (PSD) was calculated. The frequency response analysis was performed with or without prestress induced by inplane static load, and the response spectrum was compared. Time series data was generated using the calculated PSD, and the time and frequency domain fatigue life were predicted and compared. The variation of stress response spectrum due to static load and predicted fatigue life according to the different structural model considering mean stress were examined and decreasing fatigue life was observed in the model with prestress of compressive static load.

등속 이동 음원의 통과소음 스펙트럼 추정에 관한 연구 (Spectral Estimation of the Pass-by Noise of an Acoustic Source)

  • 임병덕;김덕기
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1597-1604
    • /
    • 2005
  • The identification of a moving noise source is important in reducing the source power of the transport systems such as airplanes or high speed trains. However, the direct measurement using a microphone running with noise source is usually difficult due to wind noise, white the source motion distorts the frequency characteristics of the pass-by sound measured at a fixed point. In this study the relationship between the spectra of the source and the pass-by sound signal is analyzed for an acoustic source moving at a constant velocity. Spectrum of the sound signal measured at a fixed point has an integral relationship with the source spectrum. Nevertheless direct conversion of the measured spectrum to the source spectrum is ill-posed due to the singularity of the integral kernel. Alternatively a differential equation approach is proposed, where the source characteristics can be recovered by solving a differential equation relating the source signal to the distorted measurement in time domain. The parameters such as the source speed and the time origin, required beforehand, are also determined only from the frequency-phase relationship using an auxiliary measurement. With the help of the regularization method, the source signal is successfully recovered. The effects of the parameter errors to the estimated frequency characteristics of the source are investigated through numerical simulations.

음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구 (In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.315-322
    • /
    • 2008
  • 발전소 밸브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 밸브 시트(seat)면의 이물질 삽입, 시트의 균열, 스템(stem) 패킹(parking) 또는 용접부위 결함 및 피로균열 둥에 의해 누설손상이 발생하고 있다. 이러한 밸브 내부누설 상태를 정밀하게 진단하고 평가하기 위해서는 음향방출기술의 적용이 필요하며, 본 논문은 현장적용이 가능한 연구를 수행하고 그 결과를 소개하고자 한다. 또한 실제 발전소에서 운전되는 다양한 밸브 조건을 토대로 실험실 실험에 의해 주변잡음, 밸브누설시의 음향레벨 및 스펙트럼 특성을 분석하고, 발전소 현장실험 결과와의 비교분석을 통하여, 밸브 누설상태에 따른 주변잡음, 음향신호 및 측정 가능한 최소 누설검출량 등의 평가방법에 대해 고찰하였다. 실험실 실험 및 현장적용 연구결과로부터 밸브누설 여부를 포함한 상태 평가와 최소 측정가능 누설검출량 평가가 가능하였으며, 향후 본 연구는 발전설비 안전운전과 밸브누설로 인한 에너지 손실 예방에 크게 기여할 것으로 기대된다.