• Title/Summary/Keyword: Acoustic Parameter

Search Result 415, Processing Time 0.026 seconds

Development of an Effective Method for Extracting Eigenvalues of Arbitrarily Shaped Acoustic Cavities (임의 형상 음향 공동의 효율적인 고유치 해석 기법 개발)

  • Kang, S.W.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.124-129
    • /
    • 2011
  • An improved NDIF method is introduced to efficiently extract eigenvalues of two-dimensional, arbitrarily shaped acoustic cavities. The NDIF method, which was developed by the authors for the eigen-mode analysis of arbitrarily shaped acoustic cavities, membranes, and plates, has the feature that it yields highly accurate eigenvalues compared with other analytical methods or numerical methods (FEM and BEM). However, the NDIF method has the weak point that the system matrix of the NDIF method depends on the frequency parameter and, as a result, a final system equation doesn't take the form of an algebra eigenvalue problem. The system matrix of the improved NDIF method developed in the paper is independent of the frequency parameter and eigenvalues can be efficiently obtained by solving a typical algebraic eigenvalue problem. Finally, the validity and accuracy of the proposed method is verified in two case studies, which indicate that eigenvalues and mode shapes obtained by the proposed method are very accurate compared to the exact method, the NDIF method or FEM(ANSYS).

  • PDF

Development of an Improved NDIF Method for Efficiently Extracting Eigenvalues and Eigenmodes of Arbitrarily Shaped Acoustic Cavities (임의 형상 음향 공동의 효율적인 고유치 및 고유모드 추출을 위한 개선된 NDIF법 개발)

  • Kang, S.W.;Yon, J.I.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.960-966
    • /
    • 2011
  • An improved NDIF method is introduced to efficiently extract eigenvalues and eigenmodes of two-dimensional, arbitrarily shaped acoustic cavities. The NDIF method, which was developed by the authors for the eigen-mode analysis of arbitrarily shaped acoustic cavities, membranes, and plates, has the feature that it yields highly accurate eigenvalues compared with other analytical methods or numerical methods(FEM and BEM). However, the NDIF method has the weak point that the system matrix of the NDIF method depends on the frequency parameter and, as a result, a final system equation doesn's take the form of an algebra eigenvalue problem. The system matrix of the improved NDIF method developed in the paper is independent of the frequency parameter and eigenvalues and mode shapes can be efficiently obtained by solving a typical algebraic eigenvalue problem. Finally, the validity and accuracy of the proposed method is verified in two case studies, which indicate that eigenvalues and mode shapes obtained by the proposed method are very accurate compared to the exact method, the NDIF method or FEM(ANSYS).

Acoustic Analysis and Design of a Direct-Radiator-Type Loudspeaker (직접방사형 스피커의 음향특성 해석및 설계)

  • 김준태;김정호;김진오
    • Journal of KSNVE
    • /
    • v.8 no.2
    • /
    • pp.274-282
    • /
    • 1998
  • A systematic procedure for designing a direct-radiator-type loudspeaker has been developed, based on the numerical vibro-acoustic analysis and the Taguchi method. The finite-element model of the speaker cone has been used to calculated the vibration response of the cone excited by the voice coil. The vibration displacement of the speaker cone has been converted into the vibration velocity and used as a boundary condition for the acoustic analysis. The acoustic frequency characteristics of the loudspeaker have been calculated by the boundary element method. The numerical results have been verified by the experiments carried out in an anechoic chamber. Some design parameters have been selected by using the Taguchi method, and the variations of the acoustic characteristics due to the changes of the parameter values have been examined using the numerical model.

  • PDF

Performance of Denoising Autoencoder for Enhancing Image in Shallow Water Acoustic Communication (천해 음향 통신에서 이미지 향상을 위한 디노이징 오토인코더의 성능 평가)

  • Jeong, Hyun-Soo;Lee, Chae-Hui;Park, Ji-Hyun;Park, Kyu-Chil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.327-329
    • /
    • 2021
  • Underwater acoustic communication channel is influenced by environmental parameters such as multipath, background noise and scattering. Therefore, a transmitted signal is influenced by the sea surface and the sea bottom boundaries, and a received signal shows a delay spread. These factors create a noise in the image and degrade the quality of underwater acoustic communication. To solve these problems, in this paper, we evaluate the performance of an underwater acoustic communication model using a denoising auto-encoder used for unsupervised learning. Noise images generated by the underwater multipath channel were collected and used as training data. Experimental results were analyzed as a PSNR parameter that expressed the noise ratio of the two images.

Nonlinear Scattering of Difference Frequency Acoustic Wave in Water-Saturated Sandy Sediment (수중 모래퇴적물에서 차주파수 음파의 비선형 산란)

  • Kim Byoung-Nam;Lee Kang Il;Yoon Suk Wang;Choi Bok Kyoung
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.347-348
    • /
    • 2004
  • Nonlinear scattering of difference frequency acoustic wave in a water-saturated sandy sediment was investigated. Difference frequency acoustic wave was observed to be scattered due to the nonlinearity of water-saturated sandy sediment when the collinear acoustic waves with two different fundamental frequencies are incident on the sediment. The pressure level of the difference frequency acoustic wave was 6 dB higher than the background noise level. It seems very useful to evaluate the nonlinear parameter of water-saturated sandy sediment without disturbing the sediment. Such nonlinear acoustic response of water-saturated sandy sediment can be used as background acoustic data for estimating the gas void fraction in marine gassy sandy sedimen.

  • PDF

Vibro-acoustic Analysis of Simplified Satellite Model by Using the Statistical Energy Analysis Technique (단순화된 위성체의 통계적 에너지 해석법을 이용한 음향-진동 연성 해석)

  • Jeong, Cheol-Ho;Ih, Jeong-Guon;Moon, Sang-Moo;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.711-714
    • /
    • 2002
  • At the lift-off condition, the combustion and Jet noise of launch vehicle produces a severe acoustic environment and the acoustic loads may be damaging to paylaod and equipments. Prediction of the acoustic environment is thus needed to support the load-resistive design and test-qualification of components. Currently, such a high frequency problem is usually dealt with by using the SEA technique, for which the assumptions should match reasonably well with the vibro-acoustic condition of system. The subsystems of SEA model was composed of 16 flat plates, 8 L-shaped beams, and 2 acoustic cavities. The frequency range was 400 Hz - 4 kHz considering the modal parameter. The experiment was performed in a high intensity acoustic chamber, in which the diffuse acoustic field was assured. By comparing the SEA analysis and the experiments, the error less than 5 dB was observed.

  • PDF

Change of Acoustic Parameter and Voice Handicap Index after Laryngeal Microsurgery (후두미세수술 후 음향지표의 변화와 환자의 만족도 비교)

  • Kim, Bum-Suk;Shin, Ji-Hun;Kim, Ki-Yong;Lee, Yong-Seop;Kim, Kyung-Rae;Tae, Kyung
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.2
    • /
    • pp.142-145
    • /
    • 2008
  • Background and Object: The aim of this study is to evaluate the change of patient's subjective voice handicap index (VHI) and acoustic parameters before and after laryngeal microsurgery for benign vocal cord disease. Materials and Method: We analyzed 78 patients who received laryngeal microsurgery for benign vocal cord disease from January 2004 to February 2007 retrospectively. There were 28 vocal polyp, 40 vocal nodule, 5 intracordal cyst and 5 Reinke's edema. Jitter, shimmer, harmony to noise ratio (HNR) were analyzed before surgery and 2-3months after surgery using the Doctor's speech science program. The voice handicap index introduced by the Pittsburgh Voice Center was used to examine patient's subjective change of voice quality. Results: Acoustic parameters of jitter, shimmer and HNR were improved in patients with vocal polyp and vocal nodule after surgery. The acoustic parameters were not improved in patients with Reinke's edema, statistically. Only jitter was improved significantly in patients with intracordal cyst (p<0.05). The VHI was significantly improved after surgery. The change of jitter and shimmer was significantly correlated with the change of VHI after surgery. Conclusion: The acoustic parameters and VHI were significantly improved in patients with benign vocal disease after laryngeal microsurgery.

  • PDF

A New Distance Measure for a Variable-Sized Acoustic Model Based on MDL Technique

  • Cho, Hoon-Young;Kim, Sang-Hun
    • ETRI Journal
    • /
    • v.32 no.5
    • /
    • pp.795-800
    • /
    • 2010
  • Embedding a large vocabulary speech recognition system in mobile devices requires a reduced acoustic model obtained by eliminating redundant model parameters. In conventional optimization methods based on the minimum description length (MDL) criterion, a binary Gaussian tree is built at each state of a hidden Markov model by iteratively finding and merging similar mixture components. An optimal subset of the tree nodes is then selected to generate a downsized acoustic model. To obtain a better binary Gaussian tree by improving the process of finding the most similar Gaussian components, this paper proposes a new distance measure that exploits the difference in likelihood values for cases before and after two components are combined. The mixture weight of Gaussian components is also introduced in the component merging step. Experimental results show that the proposed method outperforms MDL-based optimization using either a Kullback-Leibler (KL) divergence or weighted KL divergence measure. The proposed method could also reduce the acoustic model size by 50% with less than a 1.5% increase in error rate compared to a baseline system.

Designing a Loudspeaker by Acoutsic Analysis and Taguchi Method (음향해석과 다구치법에 의한 스피커 설계)

  • 김준태;김정호;김진오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.568-574
    • /
    • 1998
  • A systematic procedure for designing a direct-radiator-type loudspeaker has been developed, based on a numerical vibro-acoustic analysis and the Taguchi method. The finite-element model of the speaker cone has been used to calculate the vibration response of the cone excited by the voice coil. The vibration response of the speaker cone has been used as a boundary condition for the acoustic analysis, and the acoustic frequency characteristics of the loudspeaker have been calculated by the boundary element method. The numerical model has been confirmed by comparing the numerical results with experimental ones obtained in an anechoic chamber. Some design parameters contributing dominantly to the acoustic characteristics have been selected by using the Taguchi method, and the variations of the acoustic characteristics due to the changes of the parameter values have been examined using the numerical model.

  • PDF

Application of Combustion Stabilization Devices to Liquid Rocket Engine (액체 로켓엔진에서 연소 안정화기구의 적용에 관한 연구)

  • Sohn Chae-Hoon;Moon Yoon-Wan;Ryu Chul-Sung;Kim Young-Mog
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.259-262
    • /
    • 2002
  • Application of combustion stabilization devices such as baffle and acoustic cavity to liquid propellant rocket engine is investigated to suppress high-frequency combustion instability, i.e., acoustic instability. First, these damping devices are designed based on linear damping theory. As a principal design parameter, damping factor is considered and calculated numerically in the chambers with various specifications of these devices. Next, the unbaffled chambers with/without acoustic cavities are tested experimentally for several operating conditions. The unbaffled chamber shows the specific stability characteristics depending on the operating condition and has small dynamic stability margin. The most hazardous frequency is clearly identified through Fast Fourier Transform. As a result, the acoustic cavity with the present design has little stabilization effect in this specific chamber. Finally, stability rating tests are conducted with the baffled chamber, where evident combustion stabilization is observed, which indicates sufficient damping effect. Thrust loss caused by baffle installation is about $2{\%}$.

  • PDF