• Title/Summary/Keyword: Acoustic Environmental Test

Search Result 82, Processing Time 0.023 seconds

Noise Test and Evaluation of a 750 kW Wind Turbine Generator (750 kW 풍력발전기의 소음 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

Experimental Tests for the Evaluation of One-dimensional and Two-dimensional Acoustic Source Locations with 50m length of a PSC Box Girder (50m PSC박스거더를 이용한 1차원과 2차원 음원위치 산정 실험)

  • Youn, Seok-Goo;Lee, Changno
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.433-442
    • /
    • 2013
  • This paper presents experimental research work for the evaluation of one-dimensional and two-dimensional acoustic source locations with 50m length of a precast prestressed concrete box girder. Acoustic events are generated by the impacts of Schmidt Hammer and the impact signals are detected by acoustic emission sensors mounted on the concrete web surface of PSC box girder with the average spacing of 9.34m. Based on the amplitude of detected acoustic signals, considering the noises developed in PSC box girder bridges, the arrival times of acoustic signals are estimated by the first arrival times of 0Volt, 0.5Volt, and 1.0Volt amplitude in each signal. Using Least Square Method, the velocities and the source locations of acoustic signals are evaluated. Based on the test results, the spacing of AE sensors and the AE sensor networks are discussed to reduce the source location errors.

A Study on the Disintegration of Sewage Sludge using Batch Ultrasonic Pretreatment (회분식 초음파 전처리를 이용한 하수슬러지의 분해에 관한 연구)

  • Ko, Hyun-Woong;Jung, Byung-Gil;Jung, Yon-Hwa;Kim, Hyeung-Seok;Jang, Seong-Ho;Sung, Nak-Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.4
    • /
    • pp.121-129
    • /
    • 2004
  • Anaerobic digestion is the most common process for sewage sludge stabilization and has benefits of VS reduction and biogas production. Many pretreatment methods have been studied to improve hydrolysis rate because the rate of sewage sludge degradation is slow in anaerobic digestion. This study mainly focused upon the effects on disintegration of sewage sludge by ultrasonic pretreatment according to the variation of acoustic density and duration of sonication time. In this study, acoustic density has been changed as follows : 33W/L, 70W/L, 88W/L, 139W/L in case of 40 kHz with the test time changes of 10min, 20min, 25min, 30min and 40min. In the comparison of $SCOD_{Cr}/TCOD_{Cr}$ variation for excess sludge and mixed sludge disintegration, the rates of $SCOD_{Cr}/TCOD_{Cr}$ have been increased in the condition of denser acoustic density and longer sonication time with acoustic frequency of 40kHz. The pH of the excess sewage sludge and mixed sewage sludge has been decreased in the condition of denser acoustic density and longer sonication time with acoustic frequency of 40kHz.

  • PDF

A Study on the Acoustic Emission Characteristics of Weld Heat Affected Zone in SWS 490A Steel(1) (SWS 490A 강의 용접 열영향부 음향방출 특성 에 대한 연구(1))

  • 이장규;우창기;박성완;윤종희;조진호;김봉각;구영덕
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.113-120
    • /
    • 2004
  • The object of this study is to investigate the effect of compounded welding through the AE(Acoustic Emission) characteristics for weld HAZ(Heat Affected Zone) under the static tensile test. This study was carried out an SWS 490A, high tension steel for electric shield metal arc welding(SMAW), $CO_2$ gas arc welding and TIG welding. Data displays are based on the measured parameters of the AE signals, along with environmental variables such as time and load. The accumulated AE event curve of HAZ definitely have the point of inflection subject to tensile test. The results of the tensile test of HAZ come out electric shield arc welding >$CO_2$ gas arc welding>TIG welding in case of single welding, but generally the tensile test of HAZ come out electric shield arc welding> TIG welding > $CO_2$ gas arc welding. These history plots give us useful and powerful information to analyze the results of material evaluation testing.

Characteristics of the Functional Panel Made from Foamed Aluminum (발포알루미늄을 이용하여 제조한 기능성 판넬 특성 연구)

  • Kim, Jae-Yong;Um, Myeong-Heon;An, Dae-Hyun;Shim, Myeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2006
  • In this work, the properties of environmentally friendly functional panel made from waste aluminum were investigated. Product quality enhancement was pursued through an improved viscosity process, a mixing process by agitating, a foaming process, a cooling process, and a color addition process. An acoustic transmission attenuation test, a sound adsorption rate measurement test, and a foaming condition and scrap mixing test were implemented. As a result, the functional panel made from waste aluminum was ultra lightweight and had excellent properties such as soundproof, sound interception, and shielding harmful electromagnetic waves. Also, the functional panel showed low thermal conductivity (about 2.2 kcal/mh) and excellent heat-insulating property.

Design of DUC/DDC for the Underwater Basestation Based on Underwater Acoustic Communication (수중기지국 수중 음향 통신을 위한 DUC/DDC 설계)

  • Kim, Sunhee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.336-342
    • /
    • 2017
  • Recently, there has been an increasing need for underwater communication systems to monitor ocean environments and prevent marine disasters, as well as to secure ocean resources. Most underwater communication systems adopted acoustic communication with a consideration of attenuation, absorption, and scattering in conductive sea water, and developed fully digital modems based on processors. In this study, a digital up converter (DUC) and a digital down converter (DDC) was developed for an underwater basestation based on underwater acoustic communication systems. Because one of the most important issues in underwater acoustic communication systems is low power consumption due to environmental problems, this study developed a specific hardware module for DUC and DDC. It supported four links of underwater acoustic communication systems and converted the sampling rate and frequency. The systemwas designed and verified using Verilog-HDL in ModelSim environment with the test data generated from baseband layer parts for an underwater base station.

Noise Test of High Speed Train along Test Track (경부고속전철 시험선구간에서 소음영향 시험평가)

  • 나희승;김선우;김정태;정성수;조대승;김준엽
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1104-1109
    • /
    • 2002
  • High speed railroad noise is one of the main causes of environmental impact. An estimate of the relevant noise levels is usually required in order to evaluate the noise barrier and the anti-noise trailer. This paper introduce the test procedure and the estimate for HST noise. The aim of this is to measure, by means of a test, the level of acoustic pressure present during the passing of a KTX(Korea Train Express), in order to satisfy the contractual requirements and the noise criteria. A number of measurements are carried out in order to estimate noise impact by HST along test track.

  • PDF

Failure Behavior of Pin-jointed Carbon/Epoxy Composites under Hygrothermal Environmentals (열습환경을 고려한 탄소섬유/에폭시 복합재의 핀 체결부 파괴거동)

  • Kim, Chan-Gyu;Hwang, Young-Eun;Yoon, Sung-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.411-413
    • /
    • 2012
  • This study has been investigated about hygrothermal environmental effects on the pin-joined carbon/epoxy composites through acoustic emission technique. The specimens were classified as three types for pin loading test : Base (before immersion), RT (room temperature immersion), HT ($75^{\circ}C$ immersion). As a results, the bearing strength of RT specimens was weakly decreased than that of base specimens. The bearing strength of HT specimens was greatly decreased than that of Base and RT specimens due to effects of simultaneous moisture and higher temperature. Also, the results from cumulative hit of acoustic emission indicated that AE events induced by matrix cracks of HT specimens was lower than that of base specimens.

  • PDF

Acoustic emission characteristics under the influence of different stages of damage in granite specimens

  • Jong-Won Lee;Tae-Min Oh;Hyunwoo Kim;Min-Jun Kim;Ki-Il Song
    • Geomechanics and Engineering
    • /
    • v.37 no.2
    • /
    • pp.149-166
    • /
    • 2024
  • The acoustic emission (AE) technique is utilized to estimate the rock failure status in underground spaces. Understanding the AE characteristics under loading conditions is essential to ensure the reliability of AE monitoring. The AE characteristics depend on the material properties (p-wave velocity, density, UCS, and Young's modulus) and damage stages (stress ratio) of the target rock mass. In this study, two groups of granite specimens (based on the p-wave velocity regime) were prepared to explore the effect of material properties on AE characteristics. Uniaxial compressive loading tests with an AE measurement system were performed to investigate the effect of the rock properties using AE indices (count index, energy index, and amplitude index). The test results were analyzed according to three damage stages classified by the stress ratio of the specimens. Count index was determined to be the most suitable AE index for evaluating rock mass stability.

A Study on the Structure Improvement of Bracket Housing for Structural Noise and Vibration Reduction in Hydraulic Breaker (유압 브레이커의 구조 소음.진동 저감을 위한 브래킷 하우징의 구조 개선에 관한 연구)

  • Kim, Bong-Suk;Kim, Min-Gi;Byun, Dong-Woo;Lee, Seong-Min;Lee, Soo-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.108-115
    • /
    • 2006
  • A hydraulic breaker is widely utilized for many civil engineering areas for the purpose of destroying objects such as rocks, concrete, or road. However, since the high-level noise and vibration by a hydraulic breaker is one of the major sources of environmental noise and recently the environmental regulations on construction equipments are also getting more strengthened, in order to solve such problems, it is certainly necessary to design and develop a hydraulic breaker with low noise and low vibration. This research is to understand the noise characteristics through the noise test and acoustic analysis of the bracket housing in a hydraulic breaker and to identify the element part to be modified based on the result of the element contribution analysis. An improved breaker model including X-typed rib shows the result of low-noise level within target frequency band compared with a commercial breaker model.