• 제목/요약/키워드: Acoustic Environmental Test

검색결과 82건 처리시간 0.022초

고에너지 음향환경시험 튜브 개발 (Development of High Intensity Progressive Wave Tube)

  • 김영기;김홍배;문상무;우성현;임종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.962-965
    • /
    • 2005
  • A high intensity progressive wave tube is installed at Korea Aerospace Research Institute (KARI) for acoustic environmental tests. The test facility has 700 mm x 800 mm cross-sectional area, and provides acoustic environment of 165 dB over the frequency range of $25Hz{\sim}10,000Hz$. The facility consists of a 6 m long acoustic wave tube, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of the facility and power generation systems are controlled to meet the requirement of the test. The shape and length of the tube has been designed by using the size of test objects and the wave propagation characteristics of the tube. The capacity of acoustic power generation systems is determined by the energy conversion of acoustic wave and the efficiency of acoustic modulators. Moreover, the paper introduces test run results of the tube. Overall of 163dB has been generated by using the test facility.

  • PDF

설정 음압 및 스펙트럼 재현을 위한 음향 환경 시험 챔버의 기본 설계 변수 선정 (Design of High Intensity Acoustic Test Facility to Generate Required Sound Pressure Level and Spectrum)

  • 김영기;우성현;김홍배;문상무;이상설
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.867-872
    • /
    • 2002
  • A high intensity acoustic test facility is constructed at Korea Aerospace Research Institute (KARI) by 2003. The reverberant chamber of the facility has a volume of 1,228 cubic meters and shall provide an acoustic environment of 152 dB over the frequency range of 25 Hz to 10,000 Hz. The facility consists of a large scaled reverberant chamber, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of a chamber and power generation systems are controlled to meet the requirement of the test. The volume of a reverberant chamber is controlled by the size of test objects and the reverberant characteristics of a chamber. The capacity of acoustic power generation systems is determined by the energy absorption of a chamber and the efficiency of acoustic modulators. Simple math is employed to calculate the required power of acoustic modulators. Moreover, the paper explains how the distribution of sound pressure level at low frequency is checked by analytical and numerical methods.

  • PDF

소형위성발사체 상단부의 음향하중시험 (Acoustic Loads Test of the Upper Stage of KSLV-I)

  • 전영두;박종찬;정의승;박정주;조광래
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.224-227
    • /
    • 2007
  • This paper introduces the results of acoustic loads test conducted on the upper stage assembly of KSLV-I, which is the first Korea space launch vehicle. A launch vehicle and its payloads are subjected to severe acoustic pressure loading when they lift off and ascent during the transonic periods. Acoustic loadings are spreaded out broad frequncy-spectrum up to 10,000Hz. Acoustic loads are a primary source of structural random vibration of the upper stage and payloads. Therefore, in order to verify the structural integrity of the upper stage assembly of KSLV-I and the survivability of its components under severe random vibration environment, acoustic loads test is conducted in the high intensity acoustic chamber with 142dB (overall SPL). The results show the structural design and component random vibration specifications well meet with the environmental requirements.

  • PDF

철도소음 저감을 위한 간섭형 방음장치 음향 설계 및 성능시험에 관한 연구 (A study on the performance test and acoustic design of interference type noise reduction device for railway noise)

  • 조준호;고효인
    • 환경영향평가
    • /
    • 제20권6호
    • /
    • pp.787-795
    • /
    • 2011
  • Noise barrier is generally used with welding of joint rail for railway noise reduction in our country. But the noise barrier for high speed railway has weak point in low frequencies about 315Hz band. In this study, For developing of Interference-type Noise Reduction Device(INRD), acoustic analysis were performed using commercial software. For verifying the improvement in the noise reduction, noise measurement before and after installing of INRD were performed in Anechoic Chamber. From these acoustic analysis and noise measurement, it was known that developed INRD has a good noise reduction performance and can be used efficiently with conventional noise barrier.

노치가 있는 콘크리트 보에서 균열검출을 위한 음향방출기법의 적용 (Application of Acoustic Emission Technique for Detection of Crack in Notched Concrete Beams)

  • 진치섭;이래철;신동익;권성진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권4호
    • /
    • pp.215-220
    • /
    • 1999
  • Concrete micro-cracks that are grown while the structures are under construction or in service, propagate gradually or rapidly by external forces and environmental effects. As described above, almost concrete structures generally have cracks, so for the safety and durability of structures, studies to detect cracks using nondestructive tests have been treated in great deal. The purpose of this study is to evaluate characteristics of AE signals detected from notched concrete beams bending test with different loading using one of nondestructive test, Acoustic Emission (AE) method. Furthermore this study predicts the location of initial crack and measures direction of crack propagation for on-line monitoring before the crack really grows in structures by using two-dimensional AE source location based on rectangular method with three-point bending test. This will allow efficient maintenance of concrete structures through monitoring of internal cracking based on acoustic emission method.

  • PDF

음향 하중에 의한 발사체의 응력해석에 관한 연구 (A Study on the Stress Analysis of Launch Vehicle due to Acoustic Loads)

  • 연정흠;윤성기;장영순;이영무
    • 한국항공우주학회지
    • /
    • 제31권8호
    • /
    • pp.91-98
    • /
    • 2003
  • 발사체의 구조해석적인 측면에서 외부하중에 따른 발사체의 반응을 파악하는 것은 중요한 일이다. 기본적으로 발사체는 응력집중이나 내부 모듈간의 변위 간섭 등이 일어나지 않게 설계되어야한다. 이를 위해서는 외부하중에 관한 연구가 선행되어야 한다. 발사체에 작용하는 외부하중 중 연소 및 배기에 의해 발생하는 음향하중은 통계적 방법으로 다루어야 하는 랜덤 하중이다. 본 연구에서는 발사시 작용하는 음향하중에 대하여 하중 함수를 구성하고, 이를 이용하여 발사체의 하중해석을 수행하였다. 음원 할당 방법으로 음향하중을 추정하여 하중함수를 구성하였고, 이를 발사체의 유한요소 모델에 적용하였다. 응력해석을 이용하여 발사체의 구조 강성을 확인할 수 있었으며, 발사체 각 섹션의 경계면에서의 가속도 파워 스펙트럴 밀도함수를 구할 수 있었다. 이러한 결과를 이용하여 각 섹션의 진동 시험에 필요한 스펙을 도출할 수 있다.

750kW 풍력발전기의 소음실증 (Noise Test and Evaluation of a 750kW Wind Turbine Generator)

  • 김석현;허욱;이현우
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

Detection of onset of failure in prestressed strands by cluster analysis of acoustic emissions

  • Ercolino, Marianna;Farhidzadeh, Alireza;Salamone, Salvatore;Magliulo, Gennaro
    • Structural Monitoring and Maintenance
    • /
    • 제2권4호
    • /
    • pp.339-355
    • /
    • 2015
  • Corrosion of prestressed concrete structures is one of the main challenges that engineers face today. In response to this national need, this paper presents the results of a long-term project that aims at developing a structural health monitoring (SHM) technology for the nondestructive evaluation of prestressed structures. In this paper, the use of permanently installed low profile piezoelectric transducers (PZT) is proposed in order to record the acoustic emissions (AE) along the length of the strand. The results of an accelerated corrosion test are presented and k-means clustering is applied via principal component analysis (PCA) of AE features to provide an accurate diagnosis of the strand health. The proposed approach shows good correlation between acoustic emissions features and strand failure. Moreover, a clustering technique for the identification of false alarms is proposed.

경부고속철도 300km/h 주행시 소음 평가 (Noise Test of High-speed Train at 300km/h)

  • 나희승;김준엽
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 춘계학술대회 논문집
    • /
    • pp.452-457
    • /
    • 2002
  • High speed railroad noise is one of the main causes of environmental impact. An estimate of the relevant noise levels is usually required in order to evaluate the noise barrier and the anti-noise trailer. This paper introduce the test procedure and the estimate for HST noise. The aim of this is to measure, by means of a test, the level of acoustic pressure present during the passing of a KTX(Korea Train Express), in order to satisfy the contractual requirements and the noise criteria. A number of measurements are carried out in order to estimate noise impact by HST along test track.

  • PDF

수중음파 센서네트워크를 위한 계층별 프로토콜의 설계 및 성능 평가 (Design and Performance Evaluation of Hierarchical Protocol for Underwater Acoustic Sensor Networks)

  • 김지언;윤남열;김영표;신수영;박수현;전준호;박성준;김상경;김창화
    • 한국시뮬레이션학회논문지
    • /
    • 제20권4호
    • /
    • pp.157-166
    • /
    • 2011
  • 최근 수중 환경 모니터링 시스템에 대한 관심이 높아지면서 수중음파센서네트워크에 관련된 연구가 활발히 진행되고 있다. 수중음파센서네트워크는 수중환경 모니터링, 수중자원탐사, 해양 데이터 수집, 군사 목적 등 다양한 분야에 활용되고 있다. 이러한 다양한 분야에서 활용 가능한 수중음파센서네트워크의 활성화를 위해서는 PHY-MAC 프로토콜의 정의가 필수적이다. 하지만, 수중음파센서네트워크는 제한된 대역폭, 다중경로 및 페이딩현상, 지상 무선통신에 비해서 낮은 음파 속도로 인한 전송 지연시간 등 수중환경의 특수성에 고려해서 구현을 해야 한다. 본 논문에서는 수중환경과 관련된 제약사항을 고려하여 적응적인 PHY 프로토콜의 주파수, 네트워크 토폴로지, MAC 프로토콜, PHY-MAC 인터페이스, 데이터 프레임 포맷을 정의하고, 구현한 시스템의 구성에 대해서 설명하며, 수중환경에서의 실제 실험을 통한 데이터를 기반으로 성능 평가를 하였다.