• Title/Summary/Keyword: Acid-etched

Search Result 293, Processing Time 0.032 seconds

AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO AIR-ABRADED ENAMEL AND DENTIN (표면처리방법에 따른 복합레진의 결합강도에 관한 실험적 연구)

  • Shin, Jae-Ho;Jang, Ki-Taeg;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.112-124
    • /
    • 1997
  • According to extensive use of composite resin which have superior esthetic property, every effort on improving bonding strength between a tooth and composite resin has been continued. Acid etching technique is a method that micro-etches the tooth surface which provides bonding with composite resin possible. Recently, there were several reports that mechanical treatment obtained from air-abrasion can provide similar bonding strength with acid etching technique. So, this experimental study was designed to compare the shear bonding strength between using air-abrasion technique and using acid etching technique. Initially, bovine teeth were divided into enamel and dentin experimental groups. Respectively each group was categorized into three subgroups. One subgroup was acid etched with 35% phosphoric acid, then bonded with composite resin. The other subgroup was air-abraded with $50{\mu}m$ $Al_2O_3$ particles sprayed with 160psi air pressure using air abrasion unit(KCP-1000, A.D.T., U.SA), and composite resin was bonded. In another subgroup, composite resin was bonded after acid etching following air-abrasion. So, enamel experimental groups were made of E1 (acid etched only), E2(air-abraded only), E3(acid etched following air-abraded), and dentin experimental groups were made of D1(acid etched only), D2(air-abraded only), D3(acid etched following air-abraded). Each subgroup had 10 specimens. Dentin bonding system(Scotchbond Multi-purpose, 3M Co., U.S.A.) and composite resin(Z-100, 3M Co., U.S.A.) were applied on treated surface using 5mm diameter gelatin capsule as manufacturer's direction. After 1200 times thermocycling between $5^{\circ}C$ and $55^{\circ}C$, shear bond strength was measured in 5mm/min crosshead speed with Instron(Instron Co., U.S.A.), and also treated enamel and dentin were observed with SEM(JEOL Co., Japan). The following results were obtained: 1. In the enamel experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 2. In the dentin experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 3. In the SEM study, air-abraded enamel and dentin had irregular and rough surfaces.

  • PDF

AN EXPERIMENTAL STUDY ON THE TENSILE STRENGTH OF COMPOSITE RESIN TO ETCHED DENTIN SURFACE (상아질면(象牙質面)에 대(對)한 복합(複合)resin 인장강도(引張強度)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Pak, Sun-Jae;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.107-113
    • /
    • 1982
  • The purpose of this study was to observe the tensile strength of composite resins to etched dentin surface with the various methods of placing bonding agent before composite resin or placing composite resin alone. Recently extracted 60 maxillary incisors were chosen. These were divided into 6 groups: Group I : Immediate Silar adaptation to the etched dentin surface with 37% phosphoric acid for 60 seconds without bonding agent. Group II : Immediate Silar adaptation to the etched dentin surface with 37% phosphoric acid for 60 seconds with bonding agent. Group III : Silar adaptation to the etched dentin surface with 37% phosphoric acid for 60 seconds after 5 minutes of bonding agent. Group IV : Immediate Enamelite adaptation to the etched dentin surfaces with 50% phosphoric acid for 120 seconds without bonding agent. Group V : Immediate Enamelite adaptation to the etched dentin surface with 50% phosphoric acid for 120 second s with bonding again. Group VI : Enamelite adaptation to the etched dentin surface with 50% phosphoric acid for 120 seconds after 5 minutes of bonding agent. All specimens were immersed in water at $37^{\circ}C$ for 24 hours before testing. The results were as follows: 1. The tensile strength of powder/liquid composite resin system was higher than that of pastel paste composite resin system. 2. The tensile strength of the composite resin group II, III, V, & VI with bonding agent was higher than that of the composite resin group I & IV without bonding agent. 3. The tensile strength of the composite resin group III & VI after 5 minutes added to bonding agent was higher than that of the composite resin group II & V immediately added to bonding agent.

  • PDF

Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias (단일, 이중 산처리 임플란트의 회전제거력 비교)

  • Kim, Jong-Jin;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.335-341
    • /
    • 2019
  • Purpose: Chemically strong-acids (HF and $HCl/H_2SO_4$) dual etching implant surfaces have higher strengths of osseointegration than machined implant surfaces. However, the dual acid treatment deteriorates the physical properties of the titanium by weakening the fatigue resistance of the implant and causing microcracks. The removal torque comparison between the dual-acid etched (hydrochloric acid, sulfuric acid, HS) and single-acid etched implants (hydrochloric acid, H) could reveal the efficiency of implant surface acid treatment. Materials and methods: Nine $3.75{\times}4mm$ dual-acid etched SLA implants and nine single-acid etched SLA implants were inserted into New Zealand rabbit tibias. After 10 days, removal torque, roughness, and wetting angle were measured. Results: Mean removal torque values were as follows: Mean removal torque were 9.94 Ncm for HS group and 9.96 Ncm for H group (P=.995). Mean surface roughness value were $0.93{\mu}m$ for HS group and $0.84{\mu}m$ for H group (P=.170). Root mean square roughness (RSq) values were $1.21{\mu}m$ for HS group and $1.08{\mu}m$ for H group (P=.294), and mean wetting angle values were $99^{\circ}$ for HS group and $98^{\circ}$ for H group (P=.829). Statistical analysis showed no significant difference between the removal torques, roughness, or wetting angles of the two groups. Conclusion: In this experiment, we found no significant difference in removal torque, roughness, or wetting angle between dual-acid etched and single-acid etched implants.

AN EXPERIMENTAL STUDY ON THE BONDING STRENGTH OF COMPOSITE RESINS TO ETCHED ENAMEL SURFACE WITH PHOSPHORIC ACID (산처리(酸處理)된 치아표면(齒牙表面)에 대(對)한 복합(複合)레진 접착강도(接着强度)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Kyung-Jung
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.19-23
    • /
    • 1979
  • This experimental study was made to investigate the tensile strength of composite resins to etched enamel surface with a 50% phosphoric acid. Recently extraced 40 maxillary incisors were chosen. These were divied into 4 groups: Group I: Restodent adaptation to the etched enamel surface with 50% phosphoric acid. Group II: Restodent adaptation to only the ground enamel surface. Group III: Hi-pol adaptation to the etched enamel surface with 50% phosphoric acid. Group IV: Hi-pol adaptation to only the ground enamel surface. The results were as follows: 1. The tensile strength of Hi-pol showed much better results than that of Restodent. 2. Hi-pol and Restodent on the ground enamel surfaces showed little difference. 3. Adhesion to enamel increased on the average over 200% after a 50% phosphoric acid etch.

  • PDF

AN EXPERIMENTAL STUDY ON THE PENETRATION OF RESTORATIVE RESINS INTO ACID-ETCHED HUMAN ENAMEL (산(酸) 부식처리(腐蝕處理)된 치아표면(齒牙表面)에 대(對)한 복합(複合)레진의 침투(浸透)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.7-12
    • /
    • 1979
  • After applying three types of composite resins - Hi-Pol composite with Enamel bond, Hi-Pol composite without Enamel bond, Restodent - to the intact and the ground surface of tooth that had been acid etched for one or two minutes, the author observed the penetration of these resins into the acid etched enamel surface with scanning electron microscope. The results were as follows. 1. All the experimented materials showed the penetration into the acid etched enamel surface, and the average depth of penetration was 7 microns. 2. There was no significant difference in the penetration of these three resins despite different etching, time. 3. The grinding of the Enamel surface before acid - etching was not effective in altering the depth of penetration of these materials.

  • PDF

OBSERVATION WITH SCANNING ELECTRON MICROSCOPE ON THE EFFECT OF THREE DENTAL ETCHANTS IN THE ENAMEL SURFACE OF ALBINO RATS (치과용 부식제가 백서 법랑질 표면에 미치는 영향에 대한 주사전자현미경적 관찰)

  • Kwon, Taik-Kyun
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.133-139
    • /
    • 1980
  • In this experiment, etching was performed on the incisor enamel surfaces of 13 Albino rats, weighted about 130gm, with both 30% and 50% concentrations of the phosphoric, citric acids, and EDTA solution for 60 seconds. Immediately after extraction of the animal teeth, laboratory procedures for scanning electron microscopic observations were made and the author derived the following conclusions: 1. On the enamel surface treated with 30% and 50% phosphoric acids, all of the periphery, center of the enamel rods, and the enamel matrices were severely etched. 2. In the etched with 30% citric acid group, only the small part of the enamel rods were etched out. In case of 50% citric acid the periphery, center of enamel rods were partially or entirely etched, and the intermatrix spaces were widened. 3. In the 30% and 50% of the EDTA etched groups, the periphery of the enamel rods explicitely were etched, and the spaces between matrices were widened.

  • PDF

A STUDY ON THE MICROSCOPIC CHANGE OF THE ENAMEL SURFACE AFTER ACID ETCHING (법랑질(琺瑯質)의 산탈회(酸脱灰)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Min, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.6 no.1
    • /
    • pp.37-50
    • /
    • 1980
  • Scanning Electron Microscopic (SEM) examination on the labial surface of 91 permanent upper incisors were made after etching procedure with phosphoric acid, sulfuric acid, nitric acid, hydro chloric acid, oxalic acid, formic acid, citric acid and zinc phosphate liquid for 2 minutes. Following results were obtained. 1. In the surfaces etched by 10%. 50% phosphoric acid, 50% sulfuric acid, 10%. 30% nitric acid, 10%. 50% oxalic acid, 10%. 30%. 50% formic acid, 30%. 50% citric acid and zinc phosphate liquid, there appeared to be a preferential removal of prism cores, but in the surfaces etched by 10% phosphoric acid, 50% nitric acid, 10%. 30% hydrochloric acid and 30% oxalic acid, the prism peripheries were removed preferentially. 2. According to Silverstone classification on enamel etching pattern the surface treated by zinc phosphate liquid, 30. 50% citric acid, 10%. 30%. 50% formic acid, 10%. 50% oxalic acid, 10%. 30% nitric acid, 50% sulfuric acid and 10%. 50%. phosphoric acid showed Type 1, and etched by 30% oxalic acid, 10%. 30% hydrochloric acid, 50% nitric acid and 10% phosphoric acid showed Type II. Etching of prism cores was by far the most common occurence. The changes produced could be related to intrinsic differences in histology and / or solubility of enamel.

  • PDF

Survival of surface-modified short versus long implants in complete or partially edentulous patients with a follow-up of 1 year or more: a systematic review and meta-analysis

  • Medikeri, Raghavendra Shrishail;Pereira, Marisca Austin;Waingade, Manjushri;Navale, Shwetambari
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.261-281
    • /
    • 2022
  • Purpose: Short implants are a potential alternative to long implants for use with bone augmentation in atrophic jaws. This meta-analysis investigated the survival rate and marginal bone level (MBL) of surface-modified short vs. long implants. Methods: Electronic and manual searches were performed for articles published between January 2010 and June 2021. Twenty-two randomized controlled trials (RCTs) comparing surface-modified short and long implants that reported the survival rate with at least 1 year of follow-up were selected. Two reviewers independently extracted the data, and the risk of bias and quality of evidence were evaluated. A quantitative meta-analysis was performed regarding survival rate and MBL. Results: The failure rates of surface-modified short and long implants differed significantly (risk ratio, 2.28; 95% confidence interval [CI], 1.46, 3.57; P<0.000). Long implants exhibited a higher survival rate than short implants (mean follow-up, 1-10 years). A significant difference was observed in mean MBL (mean difference=-0.43, 95% CI, -0.63, -0.23; P<0.000), favoring the short implants. Regarding the impact of surface treatment in short and long implants, for hydrophilic sandblasted acid-etched (P=0.020) and titanium oxide fluoride-modified (P=0.050) surfaces, the survival rate differed significantly between short and long implants. The MBL differences for novel nanostructured calcium-incorporated, hydrophilic sandblasted acid-etched, and dual acid-etched with nanometer-scale calcium phosphate crystal surfaces (P=0.050, P=0.020, and P<0.000, respectively) differed significantly for short vs. long implants. Conclusions: Short surface-modified implants are a potential alternative to longer implants in atrophic ridges. Long fluoride-modified and hydrophilic sandblasted acid-etched implants have higher survival rates than short implants. Short implants with novel nanostructured calcium-incorporated titanium surfaces, hydrophilic sandblasted acid-etched surfaces, and dual acid-etched surfaces with nanometer-scale calcium phosphate crystals showed less marginal bone loss than longer implants. Due to high heterogeneity, the MBL results should be interpreted cautiously, and better-designed RCTs should be assessed in the future.

A study on the Optical and electrical characteristics of Tri-silicon using wet texture (습식텍스쳐를 이용한 삼결정 실리콘 광학적.전기적 특성 연구)

  • Han, Kyu-Min;Yoo, Jin-Su;Yoo, Kwon-Jong;Lee, Hi-Deok;Choi, Sung-Jin;Kwon, Jun-Young;Kim, Ki-Ho;Yi, Jun-Sin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.180-182
    • /
    • 2009
  • Two different wet etching solutions, NaOH 40% and Acid, were used for etching in tri-crystalline Silicon(Tri-Si) solar cell fabrication. The wafers etched in NaOH40% solution showed higher reflectance compared to the wafers etched in Acid solution after $SiN_x$ deposition. In light current-voltage results, the cells etched in Acid solution exhibited higher short circuit current and open circuit voltage than those of the cells etched in NaOH 40% solution. We have obtained 16.70% conversion efficiency in large area($156cm^2$) Tri-Si solar cells etched in Acid solution.

  • PDF

HISTOMORPHOMETRIC STUDY OF DENTAL IMPLANTS WITH DOUBLE ACID-ETCHED AND ANODIC OXIDIZED SURFACE IN THE RABBIT TIBIA (토끼 경골에서 치과용 임프란트의 이중 산부식 및 양극 산화 표면처리에 따른 조직계측학적 연구)

  • Han, Ye-Sook;Kim, Il-Kyu;Chang, Keum-Soo;Park, Tae-Hwan;Jeon, Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.434-444
    • /
    • 2006
  • This study was performed to evaluate the effects of three different implant surface treatments to the bone formation during osseous healing period under unloading conditions. Machined, double-acid etched and anodic oxidized implants were inserted into tibia of 3.0 - 3.5 kg NZ white male rabbits and 2 animals of each group were sacrificed at 2, 4 and 8 weeks. The specimens containing implant was dehydrated and embedded into hard methylmethacrylate plastic. After grinding to $50{\mu}m$, the specimens were stained with Villanueva bone stain. From each specimen, histomorphometric evaluation and the bone implant contact rate were analysed with optical microscope. The results were as follows; 1. In the scanning electronic microscopic examination, machined surface implant had several shallow and paralleled scratches on plain surface, double acid-etched implant had lots of minute wrinkles, rough valley and also irregularly located craters that looked like waves, anodic oxidized surface implant had porosity that minute holes were wholly distributed on the surface. 2. After 2 weeks of implantation, the percentages of bone-to-implant contact in the machined implant, double acid-etched implant and anodic oxidized implant were 26.85%, 62.64% and 59.82%, after 4 weeks of implantation they were 64.29%, 77.85% and 75.23%, and after 8 weeks they were 82.66%, 85.34% and 86.39%. 3. After 2 weeks of implantation, the percentages of bone area between threads in the machined implant, double acid-etched implant and anodic oxidized implant were 21.55%, 42.81%, and 40.33%, after 4 weeks of implantation they were 49.32%, 62.60% and 75.56%, and after 8 weeks they were 71.62%, 87.73% and 83.94%. In summary, percentages of implant surface contacted to bone trabeculae and bone formation area inside threads in double acid-etched implants and anodic oxidized implants were greater than machined implants in early healing stage. These results suggest that double acid-etched and anodic oxidized surface implants could reduce the healing period for osseointegration and may enable to do early function.