• Title/Summary/Keyword: Acid-base Indicator

Search Result 24, Processing Time 0.026 seconds

Spectrophotometric Determination of Acidic Strength of Some Acids in Acetic Acid Medium (분광광도법에 의한 아세트산에서의 몇가지 산의 세기 측정에 관한 연구)

  • Ki-Won Cha;Sung-Wook Hong;Chang-Suk Yang;Ikchoon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.452-456
    • /
    • 1987
  • Acidic strength of benzenesulfonic acid (HBs) and it's derivatives, p-toluenesulfonic acid(HTs), p-chlorobenzenesulfonic acid(HCs) and m-nitrobenzenesulfonic acid(HNs), were measured in the anhydrous acetic acid medium by spectrophotometry. p-naphtholbenzein (PNB) was used as an indicator base and the ionization constants of HTs, HBs, HCs and HNs were $3.5{\times}10^2,\;4.1{\times}10^2,\;19.3{\times}10^2\;and\;50{\times}10^2$, respectively, at 20.0${\pm}$0.1$^{\circ}$C.

  • PDF

Studies on the Organic Base Complexes and their Application to Analytical Chemistry. I. A Study on the Formation of Chlorpromazine Bromothymol Blue Complex and its Application to Analytical Chemistry. (4 유기염기착화합물의 분석화학적연구 I. Chlorpromazine Bromthymol Blue Complex 의 분석화학적연구)

  • 김차덕;심상혁;서정현
    • YAKHAK HOEJI
    • /
    • v.9 no.1_2
    • /
    • pp.14-17
    • /
    • 1965
  • It has been known that the organic base complexes formed with the anionic acid base indicators are highly soluble in non-polar solvents but relatively insoluble in water. In the work reported here the formation of the complex between chloropromazine and bromothymol blue was studied and applied it to the determination of the base. The values to determine the binding ratio of the base with the indicator at pH 3.5 obtained from the application of Job's method of continuous variation and mol ratio method were both 1:1. From the application of this reaction to the determination of the base with carbon tetrachloride as the solvent for the extraction, fairy good results have been obtained.

  • PDF

Spectrophotometric, pH-metric and Conductometric Studies on Some 3-Arylhydrazone Derivatives of (2-Thenoyl) Ethylpyruvate) (2-Thenoyl Ethylpyruvate의 몇 가지 3-Arylhydrazone 유도체에 대한 분광광도법, pH 및 전도도법 연구)

  • El-Dossoki, F. I.;El-Seify, F. A.
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.2
    • /
    • pp.99-106
    • /
    • 2006
  • The electronic absorption spectra of [3-(2-thenoyl) 3-(p-NO2-phenylhydrazone) ethyl pyruvate] (I), p-Br (II) and p-CH3 (III) were studied in ethanol and the spectra comprise four absorption bands which assigned to the corresponding electronic transition. The pK values of these compounds have been determined spectrophotometrically and pH-metrically, the results shown that the interval range for color change of compound (I) is (8-10) similar to that of phenolphethalin indicator, indicating that this compound can be used as acid-base indicator. The successive stability constants of the compounds under study with some transition elements (Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO2(II), La(III) and Zr(IV) have been determined pH- metrically. Stoichiometric complexes with ratios 1:1 and 1:2 (M: L) were formed for all metals. The pK of the three derivatives and the values of the stability constant (logK) of the complexes have the order; III > II > I. Also conductometric titrations have been carried out and the results show that this titration can be used for determination of both the metal ion and the ligand concentrations by each others.

Portable titrator equipped spectroscopic detectors; Spectrator (분광학적 검출기가 내장된 휴대용 적정기: 스펙트레이터)

  • Shin, Jiwon;Chae, Gyoyoon;Kim, Yeajin;Kim, Sangho;Chae, Yoonsu;Chae, Won-Seok
    • Analytical Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • During titration, several chemical reactions result in changes not only in the potential of chemicals, but also in the colors of the indicator. In a potentiometric titration, a titration curve is obtained by measuring the abrupt change in the potential at the endpoint. Generally, acid-base titration is performed by observing the color change caused by an indicator to determine the endpoint. The method of determining the endpoint by measuring the potential difference has been well established and commercialized; however, the devices that can obtain the endpoint by observing the color change are limited. Consequently, in this study, a simple and precise spectral endpoint detector was manufactured using a drop-counter comprising an infrared emitter and a phototransistor, a white light LED as the light source and photodetector, and an analog-to-digital converter (Arduino). Spectrator, a new named, showed excellent results in terms of the reproducibility of acid-base titration using thymol blue as an indicator. Herein, we present the results of the Spectrator-manufacturing process as well as the experimental results.

Behaviour of Acid-Base Indicators in the Aqueous Organic Solutions. (수-유기용매혼합용매중의 산-염기지원약에 관한 연구)

  • 용군호
    • YAKHAK HOEJI
    • /
    • v.19 no.1
    • /
    • pp.30-35
    • /
    • 1975
  • pKi values and sensitivity of acid-base indicators in the mixed solvent systems of water-alcohols and water-acetone at differential pH and in concentration media were determined by spectrophotometric method. When the concentration of the organic solvents were increased, the pKi values of sulfophthalein indicators, thymol blue and bromcresol purple, became larger whereas those of an axo indicator, methyl yellow, became smaller nad the pH values of the equivalent points of acids became smaller and the pH values of the equivalent points of acids became higher than those in the aqueous solution. potassium bicarbonate, a standard compound used in the organic solvent systems without a prerequisite procedure of expelling carbon dioxide by boiling.

  • PDF

Properties and Application as the Indicator of N-4-Salicyloamido-2-Amino-6-Piperidinopyrimidine 3-Oxide Fe(III) Complex (N-4-살리실로아미도-2-아미노-6-피페리디노피리미딘 3-옥사이드${\cdot}$철(III) 착체의 물성 및 지시약적 응용성)

  • Lee, Jong-Pill;Shin, Joon-Su;Kim, Kyoung-Soon;Hong, Seon-Pyo;Kim, Kyeong-Ho;Kim, Bak-Kwang
    • YAKHAK HOEJI
    • /
    • v.40 no.6
    • /
    • pp.670-678
    • /
    • 1996
  • The combinations of N-4-salicyloamido-2-amino-6-piperidinopyrimidine 3-oxide (Salmi) and two transitional metals were colored. Among metals, Fe(III) made a distinct colored comp lex with Salmi. The mole ratio of Salmi and Fe(III) in the complex was 1:1. This Salmi-Fe(III) complex was recrystallized in Hexane/Acetone(=10/1, v/v) and investigated its physicochemical properties. The color of this complex was changed by pH.; deep violet pink in acids, orange in neutral, and yellow in bases. The range of color change was approximately 0.7 pH unit. Acid-base titration of various acidic or basic drugs using Salmi-Fe(III) complex as an indicator showed good accuracy and reproducibility.

  • PDF

An Analysis and Improvement of the Experiment of the Acid-Base Neutralization Reaction (산-염기 중화반응 실험의 문제점 분석 및 개선 방안)

  • Jeon, Yeong-Hwa;Hong, Lan-Sun;Kang, Young-Jin;Kang, Seong-Joo
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.2
    • /
    • pp.189-194
    • /
    • 2004
  • The aim of this study is to analyze and improve the experiment of the acid-base neutralization reaction described in science textbooks. The problems in the neutralization reaction of NaOH-HCl solution were following; 1) the decoloration of phenolphthalein solution, 2) the color change of the titrated solution during condensation for the confirmation of the salt crystals, 3) the difficulty for the confirmation of the salt crystals. These problems are explained by the structure change of phenolphthalein and the improved experiment is proposed.

Study on Optical Characteristics of pH Indicators in the Immobilized Film for Fiber-Optic pH Sensor (광학적 pH 센서를 위한 지시염료가 고정된 필름의 광학적 특성 연구)

  • Kim, Beom Kyu;Park, Byung Gi
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.414-419
    • /
    • 2017
  • The optical characteristics of cresol red, phenol red, and neutral red immobilized in the thin film were investigated with absorbance measurement in order to find a sensing part of a fiber-optic pH sensor. Sol-Gel method with tetramethyl orthosilicate as a precursor was used to immobilize the pH indicators in the thin film. The absorbance spectra were measured when pH indicators were immobilized in the film and were dissolved in the buffer solution. Experimental results showed that the absorbance spectra could be changed when the pH indicator is immobilized in the thin film. As compared with other pH indicators, the neutral red exhibited similar absorbance spectra regardless of physical conditions and was sensitive over whole pH range between 4 and 11. In addition, the absorbance ratio of base peak to acid peak tended to increase in proportion to the increase in pH. Experimental results indicate that the neutral red is a good pH indicator for fabrication of a sensing part of the fiber-optic pH sensor.

Qualitative and quantitative analysis of furosine in fresh and processed ginsengs

  • Li, Yali;Liu, Xiaoxu;Meng, Lulu;Wang, Yingping
    • Journal of Ginseng Research
    • /
    • v.42 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • Background: Furosine (${\varepsilon}$-N-2-furoylmethyl-L-lysine, FML) is an amino acid derivative, which is considered to be an important indicator of the extent of damage (deteriorating the quality of amino acid and proteins due to a blockage of lysine and a decrease in the digestibility of proteins) during the early stages of the Maillard reaction. In addition, FML has been proven to be harmful because it is closely related to a variety of diseases such as diabetes. The qualitative analysis of FML in fresh and processed ginsengs was confirmed using HPLC-MS. Methods: An ion-pair reversed-phase LC method was used for the quantitative analysis of FML in various ginseng samples. Results: The contents of FML in the ginseng samples were 3.35-42.28 g/kg protein. The lowest value was observed in the freshly collected ginseng samples, and the highest value was found in the black ginseng concentrate. Heat treatment and honey addition significantly increased the FML content from 3.35 g/kg protein to 42.28 g/kg protein. Conclusion: These results indicate that FML is a promising indicator to estimate the heat treatment degree and honey addition level during the manufacture of ginseng products. The FML content is also an important parameter to identity the quality of ginseng products. In addition, the generation and regulation of potentially harmful Maillard reaction products-FML in ginseng processing was also investigated, providing a solid theoretical foundation and valuable reference for safe ginseng processing.

Development of Experimental Device for Analysis of Hydraulic Oil Characteristics with Dielectric Constant Sensors (유전상수 센서를 이용한 유압 작동유의 분석을 위한 실험장비 개발)

  • Hong, Sung-Ho
    • Tribology and Lubricants
    • /
    • v.37 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • An experimental device was developed for analysis of hydraulic oil characteristics with dielectric constant sensors. Online analysis is the most effective method of the three methods used for analyzing lubricant oils. This is because it can monitor the machine condition effectively using oil sensors in real time without requiring excellent analysis skill and eliminates human errors. Determining the oil quality usually requires complex laboratory equipment for measuring factors such as density, viscosity, base number, acid number, water content, additive, and wear debris. However, the electric constant is another indicator of oil quality that can be measured on-site. The electric constant is the ratio of the capacitance of a capacitor using that material as a dielectric, compared with a similar capacitor that has a vacuum as its dielectric. The electric constant affects the factors such as the base oil, additive, temperature, electric field frequency, water content, and contaminants. In this study, the tendency of the electric constant is investigated with a variation of temperature, water content, and dust weight. The experimental device can control working temperature and mix the contaminants with oil. A machine condition monitoring program developed to analyze hydraulic oil is described. This program provides graph and digital values with variation of time. Moreover, it includes an alarm system for when the oil condition is bad.