• 제목/요약/키워드: Accuracy of measurement

검색결과 3,976건 처리시간 0.035초

저전류 측정 시스템에서의 정밀도 및 측정 속도 향상 (The Improvement of Accuracy and Measurement Speed in the Low Current Measurement System)

  • 백왕기;최인규;박종식;이경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.550-553
    • /
    • 2002
  • A source meter is a basic instrument to perform a measurement of DC characteristic of semiconductor devices. the source meter can be used as variable voltage source, variable current source, voltage meter, or current meter. The accuracy of the low current measurement can be improved with the compensation of leakage current and charge and discharge current. In the low current measurement, the RC time constant is extremely big, so the measurement speed is very low. In this thesis, the analysis of the behavior of the measurement current according to the RC time constant and output capacitance and the method to accelerate the measurement speed.

  • PDF

수치근접사진측량에 의한 고해상도 디지털 카메라의 석재표면 거칠기 측정정확도 파악 (Analysis of Stone′s Surface Roughness Measurement Accuracy of a High Resolution Digital Camera by Digital Close-Range Photogrammetry)

  • 안기원;이효성;유주현
    • 한국측량학회지
    • /
    • 제18권2호
    • /
    • pp.135-141
    • /
    • 2000
  • 본 연구에서는 수치근접사진측량기법에 의한 DCS 420 디지털 카메라의 석재표면 거칠기 측정정확도 파악을 위하여 윈도우 환경의 Microsoft Visual basic 6.0으로 표면거칠기측정시스템을 구축하였다. 본 시스템을 통하여 거칠기가 거의 없는 이상적인 평면과 곡면인 돌의 표면 거칠기를 최소제곱법으로 기준면을 적용, 측정한 결과 $\pm$0.1 mm이하의 정확도로 측정할 수 있었다.

  • PDF

고정밀 24비트 디지털 데이터로거를 이용한 철도구조물의 경사계측에 관한 연구 (A Study of Incline Measurement using High Accuracy Digital Datalogger System for Railway Structures)

  • 이승원;이근호;정재민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.249-254
    • /
    • 2008
  • The objective of this study is the developement of real time automatic incline measurement using high accuracy digital datalogger for safety and maintence of railway construction sites. For the replacement of current 16 bit analog/digital converter, Digital datalogger system using 24 bit analog/digital converter is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the automatic high accuracy digital datalogge system. The results of this study will be using real time automatic incline measurement of railway structures.

  • PDF

철도구조물 진동계측에의 고정밀 디지털 데이터로거 적용성 연구 (A Study of Dynamic Measurement using High Accuracy Digital Datalogger System for Railway Structures)

  • 이승원;이근호;정재민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1006-1011
    • /
    • 2008
  • The objective of this study is the developement of real time automatic dynamic measurement using high accuracy digital datalogger for safety and maintence of railway construction sites. For the replacement of current 16 bit analog/digital converter, Digital datalogger system using 24 bit analog/digital converter is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the automatic high accuracy digital datalogger system. The results of this study will be using real time automatic dynamic measurement of railway structures.

  • PDF

응급구조(학)과 학생의 혈압측정 모형을 활용한 혈압측정 정확도 (Accuracy of blood pressure measurements taken using a blood pressure simulator by paramedic students)

  • 최은숙
    • 한국응급구조학회지
    • /
    • 제19권1호
    • /
    • pp.7-17
    • /
    • 2015
  • Purpose: We gathered information for the development of a blood pressure measurement education program by analyzing the accuracy of reading taken using a blood pressure simulator by Korean paramedic students. Methods: Data from 131 students were collected in November 12-20, 2013, and April 2-4, 2014. A 27-item questionnaire was administered, the accuracy of measurements confirmed using a blood pressure simulator (BT-CEAB), and the data analyzed (SPSS v 21.0). Results: The accuracy of systolic and diastolic blood pressure readings (${\leq}2mmHg$) was relatively low (27.5%). The mean blood pressure knowledge score was 67.61 points; significant differences were noted considering the sex (p = .001), hours of practice (p =.007), numbers of practice (p = .001), and reported self-confidence (p = .026). The blood pressure measurement accuracy group did not show a significant difference in its knowledge of blood pressure (p = .198). Conclusion: Most subjects needed several practice sessions to master the skill of measuring blood pressure. The feedback provided by individual assessment and the practice education program will serve as the basis for clinical and prehospital practice.

선박 방사소음의 측정방법 및 정확도 해석 (Ship Radiated Noise Measurement Methods and Accuracy Analysis)

  • 이필호;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.738-748
    • /
    • 2005
  • The ship radiated noise level fluctuates by the difference of interference and reverberation according to measurement methods and environmental conditions. These phenomena cause error of the source level estimation even in the same environment conditions. This paper describes a quantitative analysis and a reduction method for an error value to the source level estimation in spatial and temporal interference environment. The design criteria of the radiated noise measurement array composed of omni-directional hydrophones and the source level accuracy in the deep water range are given. The source level accuracy in the shallow water range is also derived based on the statistical model of the multiple reflection paths. The results are verified using the water tank experiment and the sea trial.

Blood pressure measurements and hypertension in infants, children, and adolescents: from the postmercury to mobile devices

  • Lim, Seon Hee;Kim, Seong Heon
    • Clinical and Experimental Pediatrics
    • /
    • 제65권2호
    • /
    • pp.73-80
    • /
    • 2022
  • A mercury sphygmomanometer (MS) has been the gold standard for pediatric blood pressure (BP) measurements, and diagnosing hypertension is critical. However, because of environmental issues, other alternatives are needed. Noninvasive BP measurement devices are largely divided into auscultatory and oscillometric types. The aneroid sphygmomanometer, the currently used auscultatory method, is inferior to MS in terms of limitations such as validation and regular calibration and difficult to apply to infants, in whom Korotkoff sounds are not audible. The oscillometric method uses an automatic device that eliminates errors caused by human observers and has the advantage of being easy to use; however, owing to its measurement accuracy issues, the development of an international validation protocol for children is important. The hybrid method, which combines the auscultatory and electronic methods, solves some of these problems by eliminating the observer bias of terminal digit preference while maintaining measurement accuracy; however, the auscultatory method remains limited. As the age-related characteristics of the pediatric group are heterogeneous, it is necessary to reconsider the appropriate BP measurement method suitable for this indication. In addition, the mobile application-based BP measurement market is growing rapidly with the development of smartphone applications. Although more research is still needed on their accuracy, many experts expect that mobile application-based BP measurement will effectively reduce medical costs due to increased ease of access and early BP management.

레이져 광학장치를 이용한 온라인 5 자유도 오차측정에 관한연구 (A Study on On-line 5 Degrees of Freedom Error Measurement using Laser Optical System)

  • 김진상;정성종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.375-378
    • /
    • 1995
  • Although laser interferometer measurement system has the advantage of range and accuracy, the traditional error measurement methods for geometric errors(two straightness and three angular errors) of a machine tool measures error components one at a time. It may also create an optical path difference and affect the measurement accuracy. In order to identify and compensate for geometric error of a moving body, an on-line measurement system for simultaneous detection of the five error components of a moving axis is required. An on-line measurement system with 5 degrees of freedom was developed for geometric error detection. Performance verification of the system was performed on an error generating mechanism. Experimental results show the feasibility of this system for identifying geometric errors of a side of machine tool.

  • PDF