• Title/Summary/Keyword: Accuracy improvement

Search Result 2,373, Processing Time 0.027 seconds

Design of a Laser Welding Machine for the Precision Improvement (용접 정밀도 향상을 위한 레이저 용접기의 구조개선)

  • Ro, Seung-Hoon;Jeong, Pyeung-Soo;An, Jae-Woo;Kang, Hee-Tae;Lee, Tae-Hoon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.13 no.4
    • /
    • pp.197-203
    • /
    • 2010
  • Laser welding is widely used for precision welding because of superior mechanical properties and high productivity. Generally the accuracy of the welding is determined by the distribution of the bead which is affected by the structural vibrations of the equipment. This study was originated to stabilize a laser welding machine to minimize the bead distribution for the precise joining. The structural properties of the laser welding machine have been investigated to analyze the major factors of the vibrations to cause the bead distribution. The ideas for the design improvement have been applied to the simulation model to identify the effects and further to achieve the stability design and to minimize the bead distribution. The result shows that a few simple design alterations can substantially suppress the structural vibrations and improve the welding accuracy. The procedure used for this study can also be applied to similar welding equipments for improving the structural stability and the welding accuracy.

  • PDF

A Study on the Improvement of Numerical Thermal Analysis for Steel Welds (철강 용접부 열해석 정도 향상에 관한 연구)

  • Kang, Youn-Hee;Kim, Choong-Myeong;Hong, Hyun-Uk;Lee, Jong-Bong
    • Journal of Welding and Joining
    • /
    • v.25 no.5
    • /
    • pp.36-44
    • /
    • 2007
  • This paper is the first part of the study on the accuracy improvement of numerical analysis of steel welds. The aim of this paper is to raise the accuracy of thermal analysis results, such as the shape and size of the weld cross section and the hardness distribution in HAZ(Heat-Affected Zone). It is known that the factors affecting on the accuracy are thermal properties, metallurgical properties and welding heat source model. It was found that the arbitrary distributed heat source model should be used to predict practical weld cross section shape and size. Also, in order to improve the prediction accuracy of HAZ hardness distribution, it was essential to consider 2 CCT(Continuous Cooling Transformation) diagrams in calculating volume fraction of transformed phases. One is the peak temperature being around melting temperature. The other is the peak temperature being around metallurgical transformation temperature.

Accuracy improvement of respiration rate based on photo-plethysmography by enhancing motion artifact (광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상)

  • Huh, Young-Jung;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.447-453
    • /
    • 2008
  • Respiration rate is one of the important vital signs. Photo-plethysmography (PPG) measurement especially on a finger has been widely used in pulse oximetry and also used in estimating respiration rate. It is well known that PPG contains respiration-induced intensity variation (RIIV) signal. However, the accuracy of finger PPG method has been controversial. We introduced a new technique of enhancing motion artifact by respiration. This was achieved simply by measuring PPG on the thorax. We examined the accuracy of these two PPG methods by comparing with two existing methods based on thoracic volume and nostril temperature changes. PPG sensing on finger tip, which is the most common site of measurement, produced 6.1 % error. On the other hand, our method of PPG sensing on the thorax achieved 0.4 % error which was a significant improvement. Finger PPG is sensitive to motion artifact and it is difficult to recover fully small respiratory signal buried in waveform dominated by absorption due to blood volume changes. Thorax PPG is poor to represent blood volumes changes since it contains substantial motion artifact due to respiration. Ironically, this inferior quality ensures higher accuracy in terms of respiration measurement. Extreme low-cost and small-sized LED/silicon detector and non-constrained reflection measurement provide a great candidate for respiration estimation in ubiquitous or personal health monitoring.

A Study on Improvement of Dimensional Accuracy in 2-axis Bending for Automotive Blow Motor Case (차량용 블로우 모터 케이스 2축 굽힘 공정의 치수 정밀도 향상에 관한 연구)

  • Kwon, Il-Keun;Kim, Gug-Yong;Park, Jun-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.419-427
    • /
    • 2018
  • In case high strength steels are applied for press-formed automotive parts, it is very difficult to secure forming accuracy due to large springback compared to moderate strength steels. In this study, a repetitive step-wise forming analyses based on secant method was proposed as the die design method for mandrel(bending tool) for the 2-axis bending equipments. A bending die with circular mandrel was designed for the DP780 blow motor case of which diameter and thickness are 70.8mm and 2.0mm respectively. Forming tests were performed to verify the validity of established die design and the results were compared with that of conventional HGI(Hot galvanized iron steel) blow motor case. For additional improvement in forming accuracy, an elliptical mandrel was proposed and its validity was verified using forming analyses based on secant method.

A Study about an estimate about machining accuracy of High Speed Machining (고속가공 가공 정밀도 예측에 관한 연구)

  • 이춘만;류승표;정원지;정종윤;고태조
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.460-465
    • /
    • 2003
  • High-speed machining is one of the most effective technology to improve productivity. Because of the high speed and high feed rate, high-speed machining can give great advantages fur the machining of dies and molds. This paper describes on the improvement of machining accuracy in high-speed machining and an estimate about machining accuracy of high-speed machining.

  • PDF

Forward Backward PAST (Projection Approximation Subspace Tracking) Algorithm for the Better Subspace Estimation Accuracy

  • Lim, Jun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1E
    • /
    • pp.25-29
    • /
    • 2008
  • The projection approximation subspace tracking (PAST) is one of the attractive subspace tracking algorithms, because it estimatesthe signal subspace adaptively and continuously. Furthermore, the computational complexity is relatively low. However, the algorithm still has room for improvement in the subspace estimation accuracy. In this paper, we propose a new algorithm to improve the subspace estimation accuracy using a normally ordered input vector and a reversely ordered input vector simultaneously.

The design of high-accuracy CMOS sampel-and-hold amplifiers (고정밀 CMOS sample-and-hold 증폭기 설계 기법 및 성능 비교)

  • 최희철;장동영;이성훈;이승훈
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.239-247
    • /
    • 1996
  • The accuracy of sample-and-hold amplifiers (SHA's) empolying a CMOS process in limited by nonideal factors such as linearity errors of an op amp and feedthrough errors of switches. In this work, after some linearity improvement techniques for an op amp are discussed, three different SHA's for video signal processing are designed, simulated, and compared. The CMOS SHA design techniques with a 12-bit level accuracy are proposed by minimizing cirucit errors based on the simulated results.

  • PDF

Research into Improvement of Circular-interpolation Accuracy (원호보간정도 향상에 관한 연구)

  • 김태원
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.624-628
    • /
    • 2000
  • The performance of machine tools is qualified by many test procedures given by the national/international standards or respected organisations. Among them, test regarding circular-interpolation accuracy is getting to be one of the important acceptance tests at the production level. Machine tool systems are composed of many mechanical and electronical sub-systems so that it is not easy to improve dynamic performance by examining only one particular part. Instead, overall systematic approach encompassing all the contributing elements is necessary to achieve good results. In this study, measures taken in circular accuracy improvements will be explained case by case.

  • PDF

A Study on the Accuracy Improvement Technique Using GPS Clock (GPS의 시각 응용에 따른 정밀도 개선에 관한 연구)

  • Chea, G.H.;Sakamoto, K.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.5-10
    • /
    • 2010
  • Both the accuracy and stability of the clock get from the GPS receiver are considered in the range of pps. And we verified the system clock stability of a micro-controller system using the pps pulse supplied by the GPS receiver. In complex system of digital processing, the rack of precise timing signal may cause the serious problem or breakdown accident. To get rid of these undesirable problems, we introduced VCXO circuit to a micro-controller system to preserve high accurate clock stability.

The Accuracy Improvement of Geo-Spatial Information in Urban Area with terrain Classification (지형분류에 따른 도심지역의 지형공간정보 정확도 향상)

  • 김정일;김현태;류지호;최동주;이현직
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.301-308
    • /
    • 2003
  • As the results of this study, the proposed method of this study which is increased to accuracy of DEM by classification of terrain is better than accuracy of DEM which is automatically generated by digital photogrammetry workstation system(DPWS). And, the edge detection method which is proposed by this study is established to extraction of geo-spatial information in ortho image.

  • PDF