• 제목/요약/키워드: Accuracy assesment

검색결과 19건 처리시간 0.036초

DLP 프린터로 제작된 레진 임시수복물의 3차원적 정확도 평가 (A Study of Three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer)

  • 강월;이희경
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.35-41
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of the DLP 3D printer by conducting 3-dimensional assesment of resin provisional restorations. Methods: The first premolar of the maxillary was prepared for the abutment. The abutment was scanned by using a scanner. The provisional restoration was designed by using CAD software. A total of 16 resin provisional restorations were produced using ZD200 and Veltz DLP 3D printer. Scanning was done of resin provisional restorations and 3-dimensional measurement was conducted for accuracy. The mean (SD) of RMS was reported for each group. Independent t-test was used to assess the statistical significance of the results. All analyses were done using SPSS 22.0. Results: The mean ± SD of RMS value for the accuracy of the resin provisional restorations that was fabricated by using ZD200 and Veltz DLP 3D printer were 50.85.±4.64㎛ and 70.33±6.31㎛. Independent t-test showed significant differences between groups(p<0.001). Conclusion: The resin provisional restorations made with DLP 3D printers showed clinically acceptable accuracy.

철근콘크리트 깊은 보의 내하력에 대한신뢰도 평가 (Reliability of Load-Carrying Capacity of RC Deep Beams)

  • 천주현;김태훈;이상철;신현목
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.955-962
    • /
    • 2005
  • 철근콘크리트 깊은 보(deep beam)는 균열 후의 구조 및 재료적 비선형성으로 인하여 아직까지 명확한 이론적인 해석 방법과 설계 방법이 정립되어 있지 않은 상태이다. 현재 내하력 평가는 주로 교량 상부 구조물에 대하여 수행되어 왔고, 그 평가 방법에 대한 적용성과 결과에 많은 불합리성을 포함하고 있다. 이 연구에서는 철근콘크리트 릴은 보의 복잡한 전단거동 특성 및 전단강도를 해석적으로 평가하고, 이를 신뢰성 이론을 바탕으로 적절하고 합리적인 내하력 평가를 수행할 수 있는 방안을 제공하는데 그 목적이 있다. 정확하고 올바른 평가를 하기 위하여 비선형유한요소해석 프로그램 RCAHEST를 사용하였다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 이에 대한 콘크리트의 균열 모델로서는 분산균열모델을 사용하였다. 이 연구에서 제안한 해석 기법과 재료적 비선형성을 고려한 해석모델을 신뢰성 있는 연구자의 실험 결과와 비교하여 그 타당성을 검증하였다. 이러한 결과를 바탕으로, Euro Code기준으로부터 철근콘크리트 깊은 보의 파괴에 대한 목표신뢰도지수를 설정하였다. 신뢰성 해석을 통하여 파괴에 대한 목표신뢰도 지수를 만족하도록 하는 감소계수를 산정하였다. 이 연구에서 제안된 철근콘크리트 깊은 보의 내하력 평가 방안을 콘크리트 구조설계기준에 의한 평가 결과와의 비교 및 분석을 통하여 타당성을 검증하였다.

공간데이터베이스의 품질평가 방법에 관한 연구 - 토지데이터베이스를 중심으로 - (A Study on the Quality Evaluation Method of Spatial Database - Focusing on Land Database -)

  • 김미정;안종천;조우현
    • Spatial Information Research
    • /
    • 제11권4호
    • /
    • pp.327-340
    • /
    • 2003
  • 공간데이터베이스의 품질평가는 공간데이터베이스의 특징에 따라 적절한 품질요소와 평가방법이 적용되어야 한다. 본 연구에서는 공간데이터베이스의 하나인 토지데이터베이스에 대한 구체적인 품질평가 방안을 제시하는데 목적을 두고 있다. 이를 위하여 토지데이터베이스를 구성하는 지형데이터베이스, 지적데이터베이스, 용도지역지구 데이터베이스의 구축 단계별 품질요소를 선정하고, 선정된 품질요소에 대하여 평가방법을 제시하였다. 토지데이터베이스의 품질요소는 위치정확성, 속성정확성, 일관성, 완결성, 시간정확성, 신뢰성, 이력 등이며, 다양한 통계적 및 수학적 방법들을 검토하여 각 품질요소의 객관적인 측정방법을 제안하였다.

  • PDF

고속철도 궤도검측 자료 분석기법에 관한 연구 (A Study of Analysis Method for the Track Geometry Measuring Data on High Speed Railway)

  • 강기동
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.291-295
    • /
    • 2004
  • The Track geometry measuring on High-speed railway is the most important subject for the track construction and track maintenance work. Also the measuring accuracy is so significant part because it provides principle data for the maintenance plan and the assesment of working quality and can control the train speed limitation. From this point of view, it is very important to verify for the track recording coach(EM120) in KNR. According to the result of spectrum analysis, the noise near 1m waveband was found on the track recording data from EM120. So, New filter has been applied to remove the noise form track recording data. and it makes possible to acquire resembling result to real track geometry.

위성영상 센서모형화의 정확도 평가방법에 관한 연구 (A Study for The Accuracy Assessment Method of Satellite Sensor Modeling)

  • 고현수;최철순;홍재민;윤창락
    • 대한공간정보학회지
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2005
  • 현재 위성영상 센서모형화의 정확도에 관한 연구는 자료의 전체적인 오차크기를 추정하는데 초점이 맞추어져 있다. 이러한 유형의 오차평가는 오차의 정량적인 크기만을 고려한 것으로 오차의 분포 특성을 해석할 수 없다는 한계점을 안고 있다. 위성영상 센서모형화 결과의 수치적 평가는 오차의 분포 특성의 부재로 위성영상 모형화 결과의 신뢰성이 떨어지게 된다. 본 연구를 통해 오차의 크기를 잘 표현할 수 있는 RMSE와 더불어 오차의 방향성 계수를 산정함으로써 오차의 분포 특성을 확인할 수 있었다. 또한 방향성 계수가 1에 가까울수록 특정 계통오차가 있으며 0에 가까울수록 우연오차가 있음을 확인 할 수 있어 오차의 방향성 분석을 통하여 오차를 감소시킬 수 있는 방안을 제시할 수 있었다.

  • PDF

몬테칼로 기법을 이용한 CBCT의 인체 내 장기의 흡수선량 평가 (Assesment of Absorbed Dose of Organs in Human Body by Cone Beam Computed Tomography using Monte Carlo Method)

  • 김종보;임인철;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권3호
    • /
    • pp.215-221
    • /
    • 2018
  • Cone beam Computed Tomography(CBCT) is an increasing trend in clinical applications due to its ability to increase the accuracy of radiation therapy. However, this leaded to an increase in exposure dose. In this study, the simulation using Monte Carlo method is performed and the absorbed dose of CBCT is analyzed and standardized data is presented. First, after simulating the CBCT, the photon spectrum was analyzed to secure the reliability and the absorbed dose of the tissue in the human body was evaluated using the MIRD phantom. Compared with SRS-78, the photon spectrum of CBCT showed similar tendency, and the average absorbed dose of MIRD phantom was 8.12 ~ 25.88 mGy depending on the body site. This is about 1% of prescription dose, but dose management will be needed to minimize patient side effects and normal tissue damage.

동영상과 수치지도의 결합에 관한 연구 (Integrating Video Image into Digital Map)

  • 김용일;편무욱
    • 대한공간정보학회지
    • /
    • 제4권2호
    • /
    • pp.161-172
    • /
    • 1996
  • 본 연구는 동영상과 수치지도를 결합하는 기법 및 공정의 개발을 그 목적으로 한다. 이를 위해 본 연구에서는 동영상을 GIS에 도입하는 과정에서 필요한 동영상의 위치색인(georeferencing)기법을 개발하고 실험용 데이터베이스를 구축하여 평가를 수행하였다. 본 연구에서 개발된 동영상의 georeferencing 기법은 DGPS를 이용한 위치측정, 이상점의 제거, 지도융합기법, time-tag을 이용한 동영상의 위치색인 등으로 구성되며, 정확한 위치가 알려져 있는 가로등을 기준점으로 위치정확도 평가를 행한 결과, 92.8%의 기준점이 전후 2프레임안에 포함되는 결과를 얻었다. 본 논문의 궁극적 의미는 기존의 2차원 수치지도의 한계를 넘어선 새로운 개념의 수치지도에 대한 가능성을 제시하였다는 것에 있다.

  • PDF

원격측정장치를 이용한 설치류의 생체신호 측정 및 분석 (Measurement and Analysis of Rodent Biological Signals using Telemetry System)

  • 김창환;허경행
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1159-1165
    • /
    • 2011
  • Telemetry techniques of rats have been used for assessing safety pharmacology of drugs and chemicals. Biological signals including blood pressure and heart rate measured under anesthesia were significantly different from those obtained under normal conditions. The stress of restraint in awake animals can also affect the accuracy of physiological evaluation. This paper details the surgery required to allow key cardiovascular parameters to be determined. The telemetric measurement of cardiovascular parameters such as blood pressure, heart rate, electrocardiograph(ECG) established. We carried out the continuous monitoring of cardiovascular parameters using the telemetry system in F344 rats. During the measurement, no significant changes were observed in the heart rate and blood pressure. ECG signals and body temperature were also constant during the measurement of biological signals. With the results of this study, we conclude that this telemetry system can be applied usefully for the assesment of biological parameters in the rats.

KICT X밴드 이중편파레이더의 레이더 강우량 정확도 평가 (Assesment of accuracy of the radar rainfall estimation for KICT X-band dualpolarization radar)

  • 윤정수;황석환;오병화;강나래
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.246-246
    • /
    • 2017
  • 서울과 같은 대도시 지역은 인구와 산업이 집중되어 있기 때문에 작은 규모의 수재해로도 큰 피해를 입을 수 있다. 또한 국지적으로 발생하는 집중호우는 도시 지역에 돌발홍수를 일으킬 수 있기 때문에 국지 예보는 도시 지역에서 매우 중요한 역할을 하고 있다. 레이더는 먼 거리에서의 악기상을 빠르게 관측할 수 있기 때문에 도시 지역 수재해 방지에 큰 역할을 할 것으로 기대되고 있다. 특히 X 밴드레이더는 높은 시공간 해상도의 관측 자료를 제공하고 있어 도시 지역에 적합한 레이더로 알려져 있다. 국내에는 건술기술연구원, 고려대학교, 연세대학교에 X밴드 이중편파레이더가 도입되어 서울 지역에서의 수재해 감시 역할을 수행하고 있다. X밴드 이중편파레이더는 반사도, 차등반사도, 차등위상차, 비차등위상차 등 다양한 레이더 편파변수들을 제공하고 있다. 이중 비차등위상차는 감쇄와 부분차폐의 영향을 받지 않아 비차등위상차로부터 추정된 레이더 강우는 큰 강우 강도에서 정확도가 높은 것으로 알려져 있다. 본 연구에서는 이러한 비차등위상차로부터 추정된 레이더 강우량에 대한 정확도를 평가하였다. 이를 위해 2013년부터 2016년까지 관측된 건설기술연구원 X밴드 이중편파레이더 자료(42개 강우사례)를 활용하였다.

  • PDF