• Title/Summary/Keyword: Accuracy Standard

Search Result 2,412, Processing Time 0.025 seconds

Statistical Analysis on the Sources of Variance in Proficiency Test of Quantitative Analysis of Medicines (의약품 함량분석 정도관리에서의 변이 요인에 대한 통계분석)

  • Cho, Jung-Hwan
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.1
    • /
    • pp.27-37
    • /
    • 2007
  • Proficiency test is an essential tool far ensuring analytical ability of analytical chemists and analytical institutes. Usually, the standard protocol for proficiency test is focused on acceptability of reported analytical results of participants by calculating z-scores and related diagnostic parameters. The ultimate goal of this process is to reveal the sources of variability of analytical results and to find the way to reduce their influence. In this study, the method of analysis of variance (ANOVA) was applied to the analytical data collected from qualify control departments of pharmaceutical companies in KyungIn province in Korea in the year of 2000. As influencing factors of variability of analytical results, the use of internal standards for liquid and gas chromatograpy, the educational and professional background of participants, geological locations and yearly production sizes of participating companies were evaluated. To evaluate the variability in accuracy of analytical results, absolute differences from sample mean and sample median were used and to evaluate variability in precision of individual participants, the reported standard deviation of each participant was used. As a result, the use of internal standards in gas chromatographic analysis, participants' academic background and the yearly production sizes of pharmaceutical companies showed statistically significant influence to the accuracy and the precision of the reported analytical results used in this study.

The Development of a Cuff for the Accuracy Enhancement of Sphygmomanometer (전자 혈압계의 정확도 향상을 위한 가압대 개발)

  • Kim Won Ki;Shin Ki Young;Mun Joung Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.181-188
    • /
    • 2005
  • The purpose of this study is to develop the new cuff improving the accuracy of blood pressure measurement, and to evaluate the performance of the developed system. We added a small bladder to the normal cuff which is called the double bladder system. The developed system for blood pressure measurement was based on the oscillometric method using a double bladder. This system was developed in order to reduce the oscillation noise and to amplify the signal of pure blood pressure An oscillometric signal database based on the developed system were evaluated following the standard ANSI/AAMI/SP10-1992. The correlation coefficients between cuff of double bladder and normal cuff were 0.98 for systolic and 0.94 for diastolic. Mean differences and the standard deviations between average blood pressure of mercury sphygmomanometer and automated sphygmomanometer were -0.7mmHg and 4.9mmHg for systolic, and -1.4mmHg and 5.4mmHg for diatolic, respectively. We conclude that the proposed double bladder based cuff system improves the accuracy of the oscillometric blood pressure measurement. The developed system reduces the error range about $44\~62\%$ for systolic and about $6\~21\%$ for diastolic compared to the recently developed commercially available sphygmomanometers.

Development of an image processing system to detect automatically intimal and adventitial contours from intravascular ultrasound images (관상동맥 혈관내부 초음파 영상에서 내벽 및 외벽 윤곽선 자동추출을 위한 영상처리 알고리즘 개발)

  • Kim, H.S.;Dove, E.L.;Chandran, K.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.27-31
    • /
    • 1994
  • Intravascular ultrasound images of coranary artery contain very important informations on heart disease. The intimal contours on the image show informations and data to examine intravascular problems of patients. A new computation algorithm to detect the intimal and adventitial contours from the intravascular images was developed. An Image processing on gray level image was used. It uses arrays of pixels in each radial lines on the images. A "Robert" filter was adopted at first step for one dimensional image processing. Some other calculation techniques were developed to inclose the accuracy of automatically detected contours. The standard contour data to compare with automatically detected contour data were obtained through manually tracing by experienced cardiological medical doctors. The result of the new algorithm shows high accuracy of 80 % matching with the standard contour data.

  • PDF

THE ACCURACY OF H$\bate$CCD PHOTOMETRY (H$\bate$CCD 측광의 정확도)

  • 김철희;김승리
    • Journal of Astronomy and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.208-231
    • /
    • 1994
  • We have undertaken CCD observations of fie이 standard stars with H$\beta$ photometric system to investigate the reliability of H$\beta$ CCD photometry. Flat fielding with dome flat and sky flat for H$\beta$w and H$\beta$n filter was compared with that of B filter in UBV system and, from these, we have not found any difference. It was confirmed that there is a good linear relationship between our H$\beta$ values observed with 2.3m reflector and standard values. However, H$\beta$ values observed with 60cm reflector at Sobaeksan Astronomy Observatory showed very poor relationship. To investigate the accuracy of H$\beta$ CCD photometry for fainter objects, open cluster NGC2437 was observed and reduced with DoPHOT, and the results were compared with those for photoelectric photometry of Stetson(1981).

  • PDF

Development of the Tolerance Design System for a Gear Drive (치차 장치를 위한 공차 설계 시스템 개발)

  • 정태형;정진욱
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2713-2722
    • /
    • 2000
  • When designing a gear drive, designers should specify tolerances reasonably considering accuracy, cost, and manufacturing capability. In field design, however, designers mostly assign adequate tolerance without correlations between parts and assembly, resulting in iterative design dependent on experts know-how. In order to resolve this, the tolerance design system for a cylindrical gear drive is developed both to support tolerance design automation and to synthesize design processes of part and assembly tolerances. In this research, part tolerances are designed with the databases constructed by ISO, Ks, JIS and bearing catalogue, Assemble tolerance, that is, backlash tolerance is designed by synthesizing part design tolerances stochastically using the formulated assembly relations. This system can include part tolerance and fitting accuracy of shaft adn bearing in practical design. In addition, this system provides field-designers with a synthetic guideline for tolerance design of a gear drive.

Cesium Frequency Standard Based on a Continuous Slow Atomic Beam (연속 저속 원자빔을 이용한 세슘 주파수 표준기)

  • Lee, Ho-Sung;Park, Sang-Eon;Kwon, Taek-Yong;Yang, Sung-Hoon;Cho, Hyuk
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.194-195
    • /
    • 2000
  • Laser-cooled slow atoms can lead to a considerable improvement in both the accuracy and the frequency stability of atomic frequency standards. Most of the developed frequency standards with the slow atoms use atomic fountain scheme that includes pulsed atomic beam. Although this type of frequency standard has already demonstrated the accuracy about 10$^{-15}$ level$^{(1)}$ , a continuous beam of slow atoms may become an alternative approach, because the pulsed operation of the atomic fountain has some drawbacks such as the collisional shift and the limitation in the short-term frequency stability. (omitted)

  • PDF

Precision Measurement of Off-AXIS OTF (비축상 OTF의 정밀측정)

  • 조현모;이윤우;이회윤;이인원
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.121-126
    • /
    • 1991
  • The knife-edge scanning type OTF measuring equipment is improved to enhance the accuracy in off-axis OTF measurement and the accuracy of this equipment of evaluated by measuring the OTF of 50 mm plano-convex standard lens developed by SIRA group. Measured MTF values of the standard lens are in good agreement with SIRA results within $\pm$0.02 on axis and % $\pm$0.03 off-axis in 0-100 clmm frequency range except only a few spatial frequencies. Measured PTF values are good agreement with SIRA results within $\pm$$5^{\circ}$.

  • PDF

A Study on the Application of Machine Learning to Improve BIS (Bus Information System) Accuracy (BIS(Bus Information System) 정확도 향상을 위한 머신러닝 적용 방안 연구)

  • Jang, Jun yong;Park, Jun tae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.3
    • /
    • pp.42-52
    • /
    • 2022
  • Bus Information System (BIS) services are expanding nationwide to small and medium-sized cities, including large cities, and user satisfaction is continuously improving. In addition, technology development related to improving reliability of bus arrival time and improvement research to minimize errors continue, and above all, the importance of information accuracy is emerging. In this study, accuracy performance was evaluated using LSTM, a machine learning method, and compared with existing methodologies such as Kalman filter and neural network. As a result of analyzing the standard error for the actual travel time and predicted values, it was analyzed that the LSTM machine learning method has about 1% higher accuracy and the standard error is about 10 seconds lower than the existing algorithm. On the other hand, 109 out of 162 sections (67.3%) were analyzed to be excellent, indicating that the LSTM method was not entirely excellent. It is judged that further improved accuracy prediction will be possible when algorithms are fused through section characteristic analysis.

A Reliability Verification of Screening Time Prediction Reporting of 'Cine-Hangeul'

  • Jeon, Byoung-Won
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.141-146
    • /
    • 2020
  • Cine-Hangeul is a program that can predict the running time of a movie based on the screenplay before production. This paper seeks to verify the prediction reporting function of Cine-Hangeul, which is the standard Korean screenplay format. Moreover, this paper presents a method to increase the accuracy of the Cine-Hangeul reporting function. The objective of this paper is to offer a correction method based on scientific evidence because the current Cine-Hangeul reporting function has many errors. The verification process for five scenarios and movies confirmed that the default setting value of Cine- Hangeul's screening time prediction reporting was many errors. Cine-Hangeul analyzes the amount of textual information to predict the time of the scene and the time of the dialogue and helps predict the total time of the movie. Therefore, if a certain amount of text information is not available, the accuracy is unreliable. The current Cine-Hangeul prediction report confirms that the efficiency is high when the scenario volume is about 90 to 100 pages. As a result, prediction of screening time by Cine-Hangeul, a Korean scenario standard format program, confirmed the verification that it could secure the same level of reliability as the actual screening time by correcting the reporting settings. This verification also affirms that when applying about 50 percent of the basic set of screening time reporting, it is almost identical to the screening time.

형광 X선에 의한 대기 부유분진중의 미량 성분의 측정 (I): -거름종이 표준시료에 의한 부유분진중 금속성분의 형광 X선 분석-

  • 이용근;맹현재;이보경;황규자
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.21-29
    • /
    • 1989
  • The metals present in atmospheric particulate come from various sources; natural or anthropogenic. Among various metals Fe, Zn, Pb, Cu, and Mn are of particular concern in as much as they are not only present in large quantity, but toxic to human body. A simple, fast, and non-destructive analytical method for these metals in atmospheric particulate was developed and the analytical details were described herein. The method involves the measurements of X-ray fluorescence of sample contained in filters and comparing it with those for standards. The standard filters were prepared by applicating premeasured standard solution to the filters and then drying. The accuracy of the method was tested by analyzing standard reference materials and by independently analyzing samples using a different, previously accuracy-proven method, inductively coupled plasma atomic emission spectrometry, and comparing the results obtained. Analytical sensitivities and detection limits of the present method were 62.9, 178.2, 82.9, 146.1, 37.2, 120.3 cps/$\mug/cm^2$ and 39.0 35.6, 137.5, 125.9, 182.6, 72.8 $ng/cm^2$ for Fe, Zn, Pb, Cu, Mn, and Ni respectively. The method was applied to Seoul atmospheric particulate and some results were reported.

  • PDF