• 제목/요약/키워드: Accumulated Energy

검색결과 430건 처리시간 0.036초

이중 ?치를 이용한 변압기형 초전도 한류기의 권선전류와 초전도소자 저항에 따른 전력소모 및 누적에너지 분석 (Analysis on Power Consumption and Accumulated Energy According to Resistance of Superconducting Element and Winding Current of Transformer Type SFCL Using Double Quench)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.630-634
    • /
    • 2016
  • In this paper, we analyzed the power consumption and the accumulated energy in HTSC (high-TC superconducting elements) according to the resistance of HTSC element and the winding current of transformer type SFCL (superconducting fault current limiter) using double quench. For the analysis, two different inductances of the one secondary winding among two secondary windings comprising the transformer type SFCL were selected and the short-circuit tests were carried out. The consumed power and the accumulated energy in HTSC element connected into the secondary winding with larger inductance were analyzed to be larger compared to the one connected into the secondary winding with lower inductance.

고장전류의 누적 에너지를 이용한 저압직류 배전계통의 고저항 지락고장 검출 알고리즘 개발 (Development of an Algorithm for Detecting High Impedance Fault in Low Voltage DC Distribution System using Accumulated Energy of Fault Current)

  • 오윤식;노철호;김두웅;권기현;한준;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.71-79
    • /
    • 2015
  • Recently, new Low Voltage DC (LVDC) power distribution systems have been constantly researched as uses of DC in end-user equipment are increased. As in conventional AC distribution system, High Impedance Fault (HIF) which may cause a failure of protective relay can occur in LVDC distribution system as well. It, however, is hard to be detected since change in magnitude of current due to the fault is too small to detect the fault by the protective relay using overcurrent element. In order to solve the problem, this paper presents an algorithm for detecting HIF using accumulated energy in LVDC distribution system. Wavelet Singular Value Decomposition (WSVD) is used to extract abnormal high frequency components from fault current and accumulated energy of high frequency components is considered as the element to detect the fault. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed algorithm using ElectroMagnetic Transient Program (EMTP) software. Simulation results considering various conditions show that the proposed algorithm can be utilized to effectively detect HIF.

Investigation on the responses of offshore monopile in marine soft clay under cyclic lateral load

  • Fen Li;Xinyue Zhu;Zhiyuan Zhu;Jichao Lei;Dan Hu
    • Geomechanics and Engineering
    • /
    • 제37권4호
    • /
    • pp.383-393
    • /
    • 2024
  • Monopile foundations of offshore wind turbines embedded in soft clay are subjected to the long-term cyclic lateral loads induced by winds, currents, and waves, the vibration of monopile leads to the accumulation of pore pressure and cyclic strains in the soil in its vicinity, which poses a threat to the safety operation of monopile. The researchers mainly focused on the hysteretic stress-strain relationship of soft clay and kinds of stiffness degradation models have been adopted, which may consume considerable computing resources and is not applicable for the long-term bearing performance analysis of monopile. In this study, a modified cyclic stiffness degradation model considering the effect of plastic strain and pore pressure change has been proposed and validated by comparing with the triaxial test results. Subsequently, the effects of cyclic load ratio, pile aspect ratio, number of load cycles, and length to embedded depth ratio on the accumulated rotation angle and pore pressure are presented. The results indicate the number of load cycles can significantly affect the accumulated rotation angle of monopile, whereas the accumulated pore pressure distribution along the pile merely changes with pile diameter, embedded length, and the number of load cycles, the stiffness of monopile can be significantly weakened by decreasing the embedded depth ratio L/H of monopile. The stiffness degradation of soil is more significant in the passive earth pressure zone, in which soil liquefaction is likely to occur. Furthermore, the suitability of the "accumulated rotation angle" and "accumulated pore pressure" design criteria for determining the required cyclic load ratio are discussed.

이력에너지 스펙트럼을 이용한 비좌굴 가새골조의 내진설계 (Energy-Based Seismic Design of Buckling-Restrained Braced Frame Using Hysteretic Energy Spectrum)

  • 최현훈;김진구
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.63-69
    • /
    • 2003
  • 본 연구에서는 단자유도계 시스템에서 작성한 이력에너지 스펙트럼과 누적된 변위 연성비 스펙트럼을 이용하여 비좌굴 가새골조의 내진설계법을 제안하였다. 먼저 목표 연성비에 해당하는 이력에너지 스펙트럼과 누적된 연성비 스펙트럼을 작성하였다. 주어진 목표 변위를 만족하기 위하여 필요한 가새의 단면적은 이력에너지 요구량과 가새에 의하여 소산된 누적 소성에너지를 같다고 하여 산정하였다. 스펙트럼을 작성하고 설계절차의 유효성을 검증하기 위하여 20개의 지진기록을 이용하였다. 제안된 방법에 따라 설계된 3층과 8층 비좌굴 가새골조의 해석결과에 따르면 최상층 변위의 평균값이 성능 목표 변위에 잘 부합됨을 알 수 있다. 또한 층간변위는 구조물 높이에 따라 비교적 일정하였는데 이것은 손상 분포가 일정하기 때문에 바람직하다. 그러므로 제안된 에너지 설계법은 기존 강도설계법의 대안으로 비좌굴 가새골조의 신뢰할만한 설계법이라고 할 수 있다.

Utilization Efficiencies of Electric Energy and Photosynthetically Active Radiation of Lettuce Grown under Red LED, Blue LED and Fluorescent Lamps with Different Photoperiods

  • Lee, Hye In;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제38권4호
    • /
    • pp.279-286
    • /
    • 2013
  • Purpose: This study was conducted to analyze the utilization efficiencies of electric energy and photosynthetically active radiation of lettuce grown under red LED, blue LED and fluorescent lamps with different photoperiods. Methods: Red LED with peak wavelength of 660 nm and blue LED with peak wavelength of 450 nm were used to analyze the effect of three levels of photoperiod (12/12 h, 16/8 h, 20/4 h) of LED illumination on light utilization efficiency of lettuce grown hydroponically in a closed plant production system (CPPS). Cool-white fluorescent lamps (FL) were used as the control. Photosynthetic photon flux, air temperature and relative humidity in CPPS were maintained at 230 ${\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, $22/18^{\circ}C$ (light/darkness), and 70%, respectively. Electric conductivity and pH were controlled at 1.5-1.8 $dS{\cdot}m^{-1}$ and 5.5-6.0, respectively. The light utilization efficiency based on the chemical energy converted by photosynthesis, the accumulated electric energy consumed by artificial lighting sources, and the accumulated photosynthetically active radiation illuminated from artificial lighting sources were calculated. Results: As compared to the control, we found that the accumulated electric energy consumption decreased by 75.6% for red LED and by 70.7% for blue LED. The accumulated photosynthetically active radiation illuminated from red LED and blue LED decreased by 43.8% and 33.5%, respectively, compared with the control. The electric energy utilization efficiency (EEUE) of lettuce at growth stage 2 was 1.29-2.06% for red LED, 0.76-1.53% for blue LED, and 0.25-0.41% for FL. The photosynthetically active radiation utilization efficiency (PARUE) of lettuce was 6.25-9.95% for red LED, 3.75-7.49% for blue LED, and 2.77-4.62% for FL. EEUE and PARUE significantly increased with the increasing light period. Conclusions: From these results, illumination time of 16-20 h in a day was proposed to improve the light utilization efficiency of lettuce grown in a plant factory.

Detection of Pulsed Photostimulated Luminescence Signals Emitted by Infrared Stimulation of Irradiated Spices during Storage under Two Conditions

  • Yi, Sang-Duk;Woo, Si-Ho;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • 제6권3호
    • /
    • pp.152-157
    • /
    • 2001
  • Accumulated photon counts in immediate measurement after irradiation of marjoram, basil and thyme were shown to be below 625$\pm$162, 577$\pm$178 and 1261$\pm$640 Pc, respectively. The accumulated photon counts increased linearly with increasing irradiation doses up to 5 kGy and slightly increased from 5 kGy to 10 kGy. This trend was similar after storage periods. According to storage conditions, the difference of the accumulated photon counts was net clearly observed. The accumulated photon counts of irradiated spice samples decreased with increasing storage periods. The rate of decrease was higher in 5 and 10 kGy irradiated samples than that in 1 kGy, and in room conditions than that in darkroom conditions. The photon counts of the irradiated spice samples measured for 120 s were higher than those measured for 60 s. The irradiated spice samples showed higher photon counts than those of unirradiated samples in both room and darkroom conditions during all the storage periods. These results indicate that detection of irradiation was still possible after 24 weeks, although the PPSL signal of all spice samples decreased with increasing storage times.

  • PDF

Influence of Sample Form, Storage Conditions and Periods on Accumulated Pulsed Photostimulated Luminescence Signals of Irradiated Korean Sesame and Perilla Seeds

  • Yi, Sang-Duk;Yang, Jae-Seung
    • Preventive Nutrition and Food Science
    • /
    • 제6권4호
    • /
    • pp.216-223
    • /
    • 2001
  • A study was carried out to examine the effect of sample form and storage conditions on the accumulated PPSL signals. Korean perilla and sesame seeds were tested as whole samples and separated minerals. Radiation-induced PPSL signals of perilla and sesame seeds themselves significantly increased with irradiation dose up to 5 kGy. On the other hand, a slight decrease in the accumulated PPSL signals was shown at 10 kGy. Similar results were also found in separated minerals. The accumulated PPSL signals of irradiated samples decreased with increasing storage periods. The decay rate was higher in 5 or 10 kGy-irradiated samples than in 1 kGy, in room conditions than in darkroom conditions, and in sesame and perilla seeds themselves than in separated minerals. The accumulated PPSL signals of the irradiated samples measured fur 120 s were higher than those measured for 60 s. These results indicated that although the PPSL signal of all samples decreased with increasing the storage time, detection of irradiated samples was still possible after 12 months of storage regardless of sample form and measurement times (60 and 120 s) in both room and darkroom conditions.

  • PDF

An Ultrasensitive FRET-based DNA Sensor via the Accumulated QD System Derivatized in the Nano-beads

  • Yang, Lan-Hee;Ahn, Dong June;Koo, Eunhae
    • BioChip Journal
    • /
    • 제12권4호
    • /
    • pp.340-347
    • /
    • 2018
  • $F{\ddot{o}}rster$ resonance energy transfer (FRET) is extremely sensitive to the separation distance between the donor and the acceptor which is ideal for probing such biological phenomena. Also, FRET-based probes have been developing for detecting an unamplified, low-abundance of target DNA. Here we describe the development of FRET based DNA sensor based on an accumulated QD system for detecting KRAS G12D mutation which is the most common mutation in cancer. The accumulated QD system consists of the polystyrene beads which surface is modified with carboxyl modified QDs. The QDs are sandwich-hybridized with DNA of a capture probe, a reporter probe with Texas-red, and a target DNA by EDC-NHS coupling. Because the carboxyl modified QDs are located closely to each other in the accumulated QDs, these neighboring QDs are enough to transfer the energy to the acceptor dyes. Therefore the FRET factor in the bead system is enhancing by the additional increase of 29.2% as compared to that in a single QD system. These results suggest that the accumulated nanobead probe with conjugated QDs can be used as ultrasensitive DNA nanosensors detecting the mutation in the various cancers.

시간영역 수동성 기법을 이용하여 시변 시간지연 하에서 안정성을 보장하는 양방향 원격제어기: 리셋 방법 (Bilateral Control with Time Domain Passivity Approach under Time-varying Communication Delay: Resetting Scheme)

  • 유지환
    • 제어로봇시스템학회논문지
    • /
    • 제14권11호
    • /
    • pp.1124-1129
    • /
    • 2008
  • Recently, two-port time-domain passivity approach was modified for time-varying communication delay. The newly proposed approach could achieve stable teleoperation even under the serious time-varying delay and packet loss communication condition. However, after some operation hour, the accumulated energy difference between the input energy from one port and the output energy at the other port caused unstable behavior until the passivity controller is activated. Resetting scheme is introduced for solving this problem, and stable bilateral teleoperation can be guaranteed without worrying about the accumulated energy difference.

서비스 사용 패턴을 고려한 홈 게이트웨이의 전력 절감 알고리즘 (Energy Saving Algorithm of the Home Gateway considering Service Usage Patterns)

  • 공인엽
    • 한국정보통신학회논문지
    • /
    • 제14권8호
    • /
    • pp.1792-1798
    • /
    • 2010
  • 홈 게이트웨이는 홈 네트워크의 지속적인 서비스를 제공해야 한다. 그러나 유비쿼터스 홈 네트워크 영역 확산될수록 홈 게이트웨이의 전력 소비는 기하급수적으로 증가한다. 이에 본 논문에서는 홈 게이트웨이가 지속적인 서비스를 유지하면서도 사용자 트래픽이 없는 구간에 저전력 모드로 전환되도록 제어한다. 이를 위해 기존의 유휴 시간 패턴을 고려하여 다음 유휴 시간을 예측하였다. 네트워크 활용 패턴의 유사성을 상세하고 가변적으로 반영하기 위하여, 요일별 생활 패턴을 프로파일링하여 적용하였다. 유휴 시간의 특성을 전체 평균과 요일별 생활 패턴으로 각각 프로파일링한 데이터를 실제값과 비교한 결과, 전체 평균 적용한 경우 유휴 시간의 예측치와 실제 값의 오차가 최소 0.43%에서 최대 4%로 나타났다. 이에 반해, 요일별 패턴을 적용한 경우, 유휴 시간의 예측치와 실제 값의 오차가 최소 0.06%에서 최대 2%로 나타났다. 이로서 네트워크 활용 패턴을 적용하는 방식이 더 효율적임을 알 수 있다.