• 제목/요약/키워드: Accreditation scheme

검색결과 42건 처리시간 0.024초

사용후핵연료의 탈피복 및 건식 분말화/혼합 장치의 타당성 분석 (Feasibility Study of a Device for Decladding and Dry Pulverizing/Mixing Spent Fuel)

  • 정재후;윤지섭;홍동회;김영환;박기용;진재현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.840-843
    • /
    • 2002
  • The dry pulverizing/Mixing device is used to deal with the spent fuels for the safe disposal. The separated pellets from hulls by a slitting device are put and oxidized from UO$_2$ solid pellet to U$_3$O$\_$8/ powder in the device. The device have been developed based on a voloxidation method which is one of several dry de-cladding methods. We have benchmarked dry de-cladding methods, analyzed applicability to the advanced spent fuel management process, integrated and compared several configuration, and finally derived detailed specifications proper to requirements for the device. Also, thermal characteristics of the device such as thermal stress and strain have been analyzed by the commercial software, 1-DEAS, and the reliability of the results have been verified by the KOLAS(Korea Laboratory Accreditation Scheme). The UO$_2$ solid pellets are put in the device which has a capacity of 20 kgHM per a batch, heated up about 600$^{\circ}C$ in the air environment. Then, the UO$_2$ solid pellets are oxidized into the U$_3$O$\_$8/ powder, and the powder is collected in a special vessel. The device has been designed and developed as fellows: the multi-staged fine hole meshes are used to reduce the size of the powder gradually, heat and air(oxygen) are supplied continuously to reduce the reaction time, and slight vibration effect are applied to collect powder cling to the device.

  • PDF

초음파식 유량계측 기술을 응용한 강수량측정장치 개발 (Development of a Precipitation Gauge Using Ultrasonic Measuring Technique)

  • 서강도;홍성택;유철;이경우;지유철
    • 한국정보통신학회논문지
    • /
    • 제17권11호
    • /
    • pp.2745-2752
    • /
    • 2013
  • 강우량을 측정하는데 있어서 전도형 및 중량형 강수량계가 전 세계적으로 오랫동안 사용되어 지고 있다. 그러나 종래의 강수량계는 관측오차와 자체 분해능의 한계로 인해 측정범위가 제한되는 문제가 있다. 본 논문에서 제안된 강수량계는 유량측정을 통해 강수량을 환산하는 원리를 최초로 적용하였으며, 개발된 모델을 국가공인교정기관(KOLAS)에서 표준교정시스템을 이용하여 실내실험을 실시하였다. 그 결과, 본 연구에서 개발된 강수량계는 실험조건에서 설정한 20~420 mm/H의 강우강도 구간에 걸쳐 ${\pm}2%$의 오차율을 나타냈고, 종래 대비 보다 정확하고 신뢰성 있는 측정이 가능함을 보였다.

브라운가스의 특성에 대한 실험적 연구 (Experimental Study on the Characteristics of Brown Gas)

  • 김창희;오규형;강경수;박주식;배기광;김종원
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2006년도 에너지.가스.기후변화학회 연합춘계학술대회 및 특별심포지움
    • /
    • pp.262-262
    • /
    • 2006
  • The characteristics of Brown gas was experimentally studied in view of efficiency and flame propagation. For this study, the Brown gas stack with 7 cells was manufactured following the Brown gas related patents and reports. All measuring equipments were re-tested and calibrated by Korea Laboratory Accreditation Scheme (KOLAS) certified laboratories. Since the amount of produced gas is most crucial in determining the efficiency, we adopted two gas collecting methods such as bottle trap method and wet gas meter method. The energy efficiency of our own fabricated stack was measured to be 75%, which is comparable to general alkaline water electrolysis efficiency. In order to analyze the flame propagation characteristics of Brown gas, we measured the flame propagation pressure, velocity, and shape by using strain type pressure sensor, optical sensor, and high speed camera in conjunction with Schliren system, respectively. From the experimental results, it was found that the flame propagation behavior of Brown gas was almost the same as that of hydrogen and oxygen mixture gas in 2:1 molar ratio. Moreover, from the high speed camera analysis, we concluded that Brown gas flame exhibits explosion behavior as does mixture gas ($H_{2}:O_{2}=2:1$).

  • PDF

전자해도 기반 중소형선박 항해 성능 모니터링 시스템 개발 (Development of a voyage performance monitoring system based on ENC for small and medium-sized vessels)

  • 이광국
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1615-1622
    • /
    • 2016
  • 본 연구에서는 항해용 국제 표준 기반의 전자해도를 기본 맵으로 육상 연안 정보 및 해저 수심 데이터를 제공하고, 선박 내 설치 운용되고 있는 자이로컴퍼스, DGPS, AIS의 각종 항해 지원 장비와의 표준 인터페이스를 제공하여 자선 및 타선의 실시간 항로 감시 및 안전운항 정보를 지원할 수 있는 중소형 선박 항해 성능 모니터링 시스템을 개발하고자 한다. 이를 위해 차량의 필수 장비인 육상 네비게이션의 기능 및 사용 방법들을 적용하여 항해자들에게 친숙한 사용 환경, 메뉴 구성, 쉬운 작동법을 제공하여 중소형 선박들이 보다 안전한 항해를 할 수 있는 장비 개발을 목표로 한다. 개발된 항해 성능 모니터링 시스템은 선박에 설치되어 있는 다양한 항해장비와의 인터페이스를 지원하고, 기존 해상 항해장비와 달리 사용자 편의를 극대화함으로써 조기에 선박간의 충돌사고 예방 및 선박 사고로 인한 인명 피해를 줄일 수 있을 것으로 판단된다.

부자식 수위계를 위한 이동형 교정시스템의 수학 모델 (Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters)

  • 홍성택;신강욱
    • 한국정보통신학회논문지
    • /
    • 제21권10호
    • /
    • pp.1964-1972
    • /
    • 2017
  • K-water에서는 2008년부터 부자식 및 초음파, 레이다식의 수위계에 대한 ISO 17025 국제공인 교정기관을 운영하고 있다. 현재까지 수위계의 교정은 고정표준실에서 실내 교정만이 가능하였으며, 이는 현장 등의 실외에서 교정하는 시스템의 부재가 원인이었다. 따라서 현장에서도 교정이 가능하도록 2015년에 이동형 교정시스템을 개발하였으며, 2016년에 각종 심사 및 위원회를 거쳐 한국인정기구(KOLAS)로부터 인정을 받았다. 본 논문에서는 한국인정기구로부터 인정받은 수위계 이동형 교정시스템 중 부자식 수위계를 현장에서 교정할 수 있는 교정시스템에 대하여 표준기 및 측정과 관련한 제반 사항에 대하여 검토하였다. 또한 설계의 기반이 되는 수학 모델을 도출하였으며, 이동형 교정시스템 구축을 통하여 수문관측 데이터에 대한 과학적인 시스템 운영으로 측정 데이터의 신뢰성을 확보하고자 하였다.

환경규제 대응을 위한 페인트 중의 중금속 분석용 인증 표준물질 개발 (Development of Certified Reference Materials for Analysis of Heavy Metals in Paints to Cope with Environmental Regulations)

  • 유병규;선일식
    • 환경분석과 독성보건
    • /
    • 제21권4호
    • /
    • pp.209-219
    • /
    • 2018
  • In the areas of RoHS, WEEE, ELV and REACH, reinforcement of environmental regulations against harmful substances is a global trend not only in EC but also in all over the world. In the fields of Korea's major export products such as material parts, electrical and electronic products and automobile parts, we are responding to these regulations consistently. To develop reference material for analyzing lead and cadmium in paints, the candidate materials were produced through the screening process which separated shapes and sizes. To secure the traceability of the candidate materials produced, the characteristics and uncertainties are estimated by ICP-AES analysis using the primary reference material. The short-term and long-term stabilities also are evaluated in parallel. In order to calculate the final certification value of the candidate material, the verification were carried out by the performance evaluation through the comparison among the KOLAS (Korea Laboratory Accreditation Scheme) laboratories, and the CRM was produced in accordance with ISO Guide 35. The certified values and uncertainties of Pb and Cd of the final paint standard, determined according to the joint analysis among laboratories, are Pb [($191.4{\pm}3.1$) mg/kg, ($944.1{\pm}5.6$) mg/kg] and Cd [($45.0{\pm}2.6$) mg/kg, ($225.5{\pm}3.5$) mg/kg]. These standard materials were developed to enhance the reliability of measurement analysis, including the validity and traceability of measurement results. Also it is expected that the CRM will be used as QCM (quality control material) for the product design and the process monitoring, so that regulation and management of hazardous heavy metals can be systematically implemented.

스마트 홈 시큐리티 기술 동향 (Technology trend of Smart-home Security System)

  • 장예진;전용태
    • 시큐리티연구
    • /
    • 제30호
    • /
    • pp.117-138
    • /
    • 2012
  • 현대 범죄의 증가로 주거공간의 범죄를 최소화 및 예방하고자 스마트 홈이 보편화되었으며, 스마트 홈 관련 시큐리티에 대한 관심이 높아지고 있다. 본 연구에서는 스마트화된 서비스를 제공하게 될 것이라는 미래의 집안환경에 대한 이해와 스마트 홈 시큐리티의 시사점 및 대응에 관련하여 제안하자면 다음과 같다. 첫째, 스마트 홈 시큐리티의 표준 수립이다. 주거공간에 있어서 자체적으로 건설사의 정책만으로 반영되거나 주민들이 필요에 의해서 개선된 내용을 적용하는 수준에 그치는 상황이며, 또한 건설사마다의 특성을 부각시켜 스마트 홈 시큐리티를 나타낼 뿐 표준화되어 있지는 못한 실정이라 정리할 수 있다. 둘째, 스마트 홈 시큐리티 인증제도 도입이다. 사람만이 가지던 자격증이 이젠 주거공간에도 자격증 시대이다. 주거공간의 성능을 나타내어 주는 인증제도는 아파트의 품질을 평가하는 절대적인 기준이 될 수 없으나, 현재 정부에서 추진하고 있는 다양한 정책과 편리한 주택환경을 위한 기본적인 요건이라 할 수 있다. 스마트 홈 시큐리티 인증제도 역시 도입하여 다른 주거공간에 상호 경쟁적으로 보안장비를 더 보강하거나 또는 경비인력을 전문화하여 인증받으려 할 것이기에 부수적인 안전확보가 가능하다고 여겨진다. 변화하는 스마트 홈 시큐리티를 연구하여 어떤 중심의 요소로 변화하고 발전하고 있는지 앞으로 어떤 변화로 대응해야할지를 연구할 필요성이 있다.

  • PDF

차량 속도 측정의 실무적용을 위한 테이프스위치 센서 방식과 영상 프레임 분석방법의 비교연구 (A Comparison Between the Tape Switch Sensor and the Video Images Frame Analysis Method on the Speed Measurement of Vehicle)

  • 김만배;현철승;유성준;홍유식
    • 대한전자공학회논문지TC
    • /
    • 제43권9호
    • /
    • pp.120-127
    • /
    • 2006
  • 현재 국내 도로에 설치되어 있는 무인교통단속장비는 속도 측정을 위해 루프 검지기를 이용하고 있으며 동 검지기의 신뢰도 평가는 주로 비디오카메라 촬영을 통한 영상프레임분석 방법을 이용하여 왔다. 그러나 영상프레임분석 방법은 국가 공인검사방법으로 인정받고 있지만 무인교통단속장비의 검정 분석 대상이 증가하면 증가할수록 자료 분석에 소요되는 경제적 비용과 소요 시간이 큰 폭으로 늘어나 실무적 어려움을 갖게 되었다. 따라서 차량 속도 측정의 실무적용의 용이성을 확보하기 위해 기존의 영상 프레임 분석 방법을 대체 내지는 보완하여 속도를 실시간으로 분석할 수 있는 새로운 속도 측정 방법의 도입이 요구되고 있다. 본 연구에서는 영상 프레임 분석 방법을 대체하고 속도정확도를 실시간으로 분석할 수 있는 방안으로써 테이프 스위치 센서를 이용한 속도 측정 시스템을 통하여 동 시스템의 신뢰도 및 현장 적용 여부를 검토하였다. 본 연구에서 구성한 테이프 스위치 센서를 이용한 속도 측정 방식과 프레임분석에 의한 기존 방식과의 비교 분석한 결과, 대체 사용하여도 무방한 것으로 평가되었다. 따라서 테이프스위치 센서를 이용한 속도측정 장치는 교통단속시스템의 실무적 검수 검정을 단시간 내에 수행할 수 있는 장점이 있어 향후 속도측정용 시험 장비로써 현장 적용 가능성이 매우 높은 것으로 판단된다.

Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석 (Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter)

  • 장지용;정문택;송종남;하재준;한재복
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2018
  • 단창형의 Geiger-Muller 계수관을 이용한 표면오염검사에서 베타선을 측정하기 위해 외부로 노출된 디텍터를 보호하는 방법으로 랩을 사용하고 있는데 이 방법이 측정계수율과 교정인자에 미치는 영향을 분석하고 방사선작업종사자에게 과도한 랩의 사용은 베타선의 측정값에 영향을 줄 수 있음을 인지시켜주고자 하였다. 실험방법은 3 KBq, 1.5 KBq, 0.3 KBq의 에너지가 다른 베타선을 이용하여 랩 두께에 따른 베타선 측정계수율과 교정인자의 변화를 비교 분석하였다. 실험 대상으로는 2012년 3월 한국인정기구 (KOLAS) 인증을 받은 교정센터에서 보유한 단창형의 Geiger-Muller 계수관을 대상으로 하였으며, Cl-36(Chlorine)과 Sr-90(Strontium)을 베타선 방사선원으로 사용하였다. 측정계수율은 랩 두께가 증가할수록 감소함을 확인 할 수 있었고 교정인자는 랩 두께가 증가할수록 증가하는 것을 알 수 있었다. 측정계수율의 감소와 교정인자의 변화는 기기지시값의 정확도를 감소시킬 수 있지만 디텍터의 오염 및 손상 또한 베타선 측정에서 중요한 영향을 주기 때문에 어느 정도 두께의 랩을 사용함이 가장 효과적인지 알아볼 필요성이 있다. 측정계수율과 교정인자의 낮은 변화율을 보여주는 두께의 랩을 사용한다면 디텍터를 보호하면서 베타선의 측정값에도 영향을 최소한으로 줄 수 있을 것으로 사료된다.

성인간호학 교육의 학습목표와 국가고시 문제 개선방안 (The Future Direction of Learning Objectives and National Nurse's Licensing Examination in Adult Health Nursing)

  • 송라윤;신수진;서연옥;신성례;박연환;강윤희;김영경
    • 성인간호학회지
    • /
    • 제23권5호
    • /
    • pp.503-513
    • /
    • 2011
  • Purpose: The purpose of this study was to identify a model based on f the learning objectives in adult health nursing curriculums. The model can be eventually reflected in Korean National Nurse's Licensing Examination (KNNLE). Methods: The model was developed through a series of practical analysis by the task force team from June to October, 2011. The research team conducted the data synthesis and analysis from the learning objectives of adult health nursing drawn from selected national and international universities, from the adult health nursing areas in KNNLE, and from the current disease prevalence from clinical data in the representative university hospitals in Korea. Results: The current disease prevalence and mortality rates are on the increase especially for malignant neoplasm, heart diseases, suicide and diabetes. The items on the KNNLE of adult nursing are categorized by body systems into digestive system (15%), introduction (13.8%), respiratory system (11.3%), and cardiac system (11.3%). While the current system-based learning objectives covers extensive areas of adult health nursing, the core items are required to be selected based on core competences and core learning objectives to restructure the items of KNNLE. The first revised model is to consolidate and restructure the items microscopically in the subjects of adult health nursing by system. The second proposed model from macroscopic perspective is to build a comprehensive scheme of nursing curriculum by encompassing 8 subjects under current KNNLE and adjust the number of items accordingly. Conclusion: The items of KNNLE need to be gradually redesigned by considering the intervention need at clinical practice and the modified learning objectives of adult health nursing. Based on the job analysis on core competences for newly employed nurses performed by the Korean Accreditation Board of Nursing, it is necessary to establish the core learning objectives of adult health nursing and set up standards for core items in KNNLE.