• Title/Summary/Keyword: Access site

Search Result 595, Processing Time 0.024 seconds

A GateSensor for Effective and Efficient Entering/Taking Management of Vehicles for Construction Logistics (건설 자재 반출입 차량 관리 효율화를 위한 게이트센서)

  • Yoon, Su-Won;Song, Jae-Hong;Shin, Tae-Hong;Chin, Sang-Yoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.1
    • /
    • pp.85-96
    • /
    • 2011
  • The access monitoring and control system of vehicles involved in construction logistics has been evolved from paper-based through bar code-based and to RFID-based management with pursuing automatic data collection and management. However, existing management methods have a limit that they still need manpower allocation for access control of vehicles. Therefore this research has proposed an framework that includes devices and an information system for effective and efficient data collection for access control of vehicles for construction logistics. And the proposed framework has been verified through a laboratory test using a prototype system developed in this research. It is expected that the installation methods of RFID antenna and tag for the framework could be applied to not only the access control of construction site but also various RFID applications at construction sites.

Evolutionary game theory-based power control for uplink NOMA

  • Riaz, Sidra;Kim, Jihwan;Park, Unsang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2697-2710
    • /
    • 2018
  • Owing to the development of Internet of Things (IoT), the fifth-generation (5G) wireless communication is going to foresee a substantial increase of mobile traffic demand. Energy efficiency and spectral efficiency are the challenges in a 5G network. Non-orthogonal multiple access (NOMA) is a promising technique to increase the system efficiency by adaptive power control (PC) in a 5G network. This paper proposes an efficient PC scheme based on evolutionary game theory (EGT) model for uplink power-domain NOMA system. The proposed PC scheme allows users to adaptively adjusts their transmit power level in order to improve their payoffs or throughput which results in an increase of the system efficiency. In order to separate the user signals, a successive interference cancellation (SIC) receiver installed at the base station (BS) site. The simulation results demonstrate that the proposed EGT-based PC scheme outperforms the traditional game theory-based PC schemes and orthogonal multiple access (OMA) in terms of energy efficiency and spectral efficiency.

Design AND IMPLEMENTATION of A News letter system using fuzzy association rules (퍼지 연관규칙을 이용한 뉴스레터 시스템 설계 및 구현)

  • 정연홍;박우수;박규석
    • Journal of Internet Computing and Services
    • /
    • v.3 no.5
    • /
    • pp.41-49
    • /
    • 2002
  • Web mining can be broadly defined as the discovery and analysis of useful information from the World Wide Web. In this paper. we tried to analyze a user access pattern and designed a system which can supply useful information to users through the web mining, The proposed system can search the information of users pattern through the web site and news letters, and pass through classification of category through filtering, The fuzzy association rules are applied to the users who access recently, to each category that generated though these processes, and compares the generated sets to each users-access pages set, and it can send appropriate news letter to each user.

  • PDF

A Development of Platforms for Boiler of Thermal Power Plant (화력발전소 보일러 수퍼히트부 안전발판 개발 연구)

  • Lee, Jung Seok;Lee, Dong Lark;Kim, Hee Kyung;Jeong, Byeong Yong;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.34-40
    • /
    • 2017
  • The catastrophic collapse of the in-boiler scaffolding system in the two thermal power plants occurred in March and April 2012. After site investigation and document review, it was found that the specialized scaffolding system was imported for overhaul & maintenance and that the system did not get the safety certification at the import. In this regard, this study developed & proposed an access platform and a support for the vertical tube section of the super heat as well as a variable-length platform for the horizontal tube section, satisfying the domestic certification standards. The access platform was developed to be easy to handle by the worker with a weight of about 0.069 kN, which could reduce the risk of falling accidents and workers' musculoskeletal diseases. For the variable-length platform, it is possible to cope with various changes in length between the horizontal tubes associated with the increase of rigidity in the overlapping and the elimination of the protrusion.

Synchronization of the LDAP(Lightweigth Directory Access Protocol) information with web site member informal ion for a SSO(Single Sign-On) setup (SSO(Single Sign-On)체제 구축을 위한 웹 사이트 회원정보와 LDAP(Lightweight Directory Access Protocol)정보 동기화)

  • Cheon inhyeuk;Yi T.S.;Lee S.H.;Kim N.G.;Shin Kijeong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.103-105
    • /
    • 2005
  • 공공 부문이나 대기업에서 운영하는 웹 사이트의 규모가 커지면서 분야별로 사이트가 나누어지게 되는데, 사이트를 이동할 때 마다 로그인을 다시 해야 하는 불편이 있다. 따라서 최근 이용자들의 불편을 줄이기 위하여 SSO (Single Sing-On) 통합인증 체제를 도입하는 사례가 늘고 있다. 통합 인증 시스템을 구축하면서 다수 웹 사이트의 회원을 통합하고 이에 대한 회원 정보 DB를 구축하여야 하는데, 빠른 인증서비스를 위해서 LDAP(Lightweight Directory Access Protocol)를 사용하는 것이 일반적이다. 이때 회원정보 DB와 LDAP의 정보에 대한 동기화 문제와 웹 사이트를 통한 회원가입과 동시에 적용되어야 하는 요구사항을 만족시키기 위해 본 논문에서는 회원 정보 DB와 LDAP의 정보 사이의 동기화 방법을 제안하고 구현하여 그 성능을 분석하였다.

  • PDF

Implementation of Intelligent Web Service Access Management for Supporting High Ava ilability and Business Continuity (고 가용성과 업무의 연속성 보장을 위한 지능적 웹 서비스 접속관리의 구현 방안에 관한 연구)

  • Joong Kang-Itrun;Lee Kwang-Eooung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.5 s.37
    • /
    • pp.151-160
    • /
    • 2005
  • High availability and business continuity in the mission critical enterprise environment have been a matter of primary concern. It is desirable to implement replicated servers, duplicated devices and disaster recovery sites so that these issues are accomplished. When that happens, web browser's users may be accessed web server through a specific Uniform Resource Locator. A critical issue arises if web browser's users recklessly change the URL and access into other site. In this case, data integrity between duplicated sites may not be guaranteed. In this paper, we introduce the method of integrating the technologies of user authentication, certificate authority and business continuity and Propose the design and implementation of intelligent service access management.

  • PDF

Safety of a Totally Implantable Central Venous Port System with Percutaneous Subclavian Vein Access

  • Keum, Dong-Yoon;Kim, Jae-Bum;Chae, Min-Cheol
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.202-207
    • /
    • 2013
  • Background: The role of totally implantable central venous port (TICVP) system is increasing. Implantation performed by radiologist with ultrasound-guided access of vein and fluoroscope-guided positioning of catheter is widely accepted nowadays. In this article, we summarized our experience of TICVP system by surgeon and present the success and complication rate of this surgical method. Materials and Methods: Between March 2009 and December 2010, 245 ports were implanted in 242 patients by surgeon. These procedures were performed with one small skin incision and subcutaneous puncture of subclavian vein. Patient's profiles, indications of port system, early and delayed complications, and implanted period were evaluated. Results: There were 82 men and 160 women with mean age of 55.74. Port system was implanted on right chest in 203, and left chest in 42 patients. There was no intraoperative complication. Early complications occurred in 11 patients (4.49%) including malposition of catheter tip in 6, malfunction of catheter in 3, and port site infection in 2. Late complication occurred in 12 patients (4.90%). Conclusion: Surgical insertion of TICVP system with percutaneous subclavian venous access is safe procedures with lower complications. Careful insertion of system and skilled management would decrease complication incidence.

Correlation Analysis between Median Household Income and LEED-Certified Public Transportation Access

  • Han, Hee Su;Kim, Boo-Young;Park, Young Jun;Son, Kiyoung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.3
    • /
    • pp.266-272
    • /
    • 2014
  • The Leadership in Energy and Environmental Design (LEED) Green Building Rating System provides third-party verification for environmentally sustainable construction. But while LEED-certified buildings provide healthier work and living environments, Previous studies have shown that LEED certification does not provide any direct economic incentives to owners and developers. To address this issue, this study aims to investigate the economic benefits of LEED criteria. The objective of this study is to examine whether or not there is a significant correlation between median household income and the number of bus stops and light rail stations for a given parcel that meet LEED sustainable site criteria for public transportation access. The findings showed that the number of bus stops had a positive correlation with median household income, which means that more bus stops a given parcel had that met LEED criteria, the greater the median household income of a block group where the given parcel was located would be, though this positive correlation was very weak.

A dual-plane approach for surgical treatment of pseudoaneurysm with arteriovenous fistula in hemodialysis patients

  • Kim, Ji Min;Tak, Min Sung;Kang, Jin Seok;Moon, Chul
    • Archives of Plastic Surgery
    • /
    • v.48 no.3
    • /
    • pp.287-292
    • /
    • 2021
  • Background We report the efficacy of a dual-plane approach using a Dufourmentel skin flap with a purse-string suture of the de-epithelized dermis to manage pseudoaneurysm at the vascular access site for hemodialysis. Methods A retrospective analysis was conducted of 61 patients from 2013 to 2018 with pseudoaneurysms at the arteriovenous fistula or graft who were treated with rhomboid excision, vessel repair with a purse-string suture, and a full-thickness Dufourmentel skin flap. The success rate was defined as the probability of complete wound closure and intact vascular access patency without infection or other complications. Results The success rate was 93.4% at 6 months postoperatively. Complications included newly occurring pseudoaneurysms (n=2), wound dehiscence (n=1) and bleeding (n=1). There were no complications such as stenosis or thrombosis from the procedure. Conclusions A dual-plane approach using a Dufourmentel skin flap with a purse-string suture for vessel repair was shown to be a favorable option for managing stable, small (diameter <2 cm) pseudoaneurysms without infection, rapid expansion, or patency issues of the vascular access.

NUMERICAL STUDY ON BLOOD FLOW CHARACTERISTICS IN A ARTERIOVENOUS GRAFT WITH DELIVERED DOSE DURING HEMODIALYSIS (인조혈관 동정맥루의 혈액 투석량에 따른 인조혈관 내부 유동 특성에 관한 수치해석 연구)

  • Kim, J.Y.;Ro, K.C.;Ryou, H.S.
    • Journal of computational fluids engineering
    • /
    • v.16 no.4
    • /
    • pp.84-91
    • /
    • 2011
  • Hemodialysis is essential for patients with end stage renal failure. It is important to improve the patency rate and to minimize occurrence of the stenosis. Also, the blood flow to the artificial kidney can affect the blood flow characteristics through arteriovenous graft. Thus, the delivered dose are important factors for analyzing hemodynamic characteristics during hemodialysis access. In this study, the numerical analysis was performed for the effect of the delivered dose during hemodialysis access on the blood flow through the graft. As a result, The adverse pressure gradient occurred in case of a larger delivered dose through a catheter than standard dose and the flow instability increased. Also the circulation flow appeared largely at anastomotic site of the vein when the delivered dose was exceeded about half blood flow of inlet blood flow.