• Title/Summary/Keyword: Acceptance Criterion

Search Result 75, Processing Time 0.036 seconds

Ship Collision Risk Analysis of Bridge Piers (선박충돌로 인한 교각의 위험도 분석)

  • Lee, Seong-Lo;Bae, Yong-Gwi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.169-176
    • /
    • 2005
  • An analysis of the annual frequency of collapse(AF) is performed for each bridge pier exposed to ship collision. From this analysis, the impact lateral resistance can be determined for each pier. The bridge pier impact resistance is selected using a probability-based analysis procedure in which the predicted annual frequency of bridge collapse, AF, from the ship collision risk assessment is compared to an acceptance criterion. The analysis procedure is an iterative process in which a trial impact resistance is selected for a bridge component and a computed AF is compared to the acceptance criterion, and revisions to the analysis variables are made as necessary to achieve compliance. The distribution of the AF acceptance criterion among the exposed piers is generally based on the designer's judgment. In this study, the acceptance criterion is allocated to each pier using allocation weights based on the previous predictions.

Ship Collision Risk Assessment for Bridges (교량의 선박충돌위험도 평가)

  • Lee, Seong Lo;Bae, Yong Gwi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.1-9
    • /
    • 2006
  • An analysis of the annual frequency of collapse(AF) is performed for each bridge pier exposed to ship collision. From this analysis, the impact lateral resistance can be determined for each pier. The bridge pier impact resistance is selected using a probability-based analysis procedure in which the predicted annual frequency of bridge collapse, AF, from the ship collision risk assessment is compared to an acceptance criterion. The analysis procedure is an iterative process in which a trial impact resistance is selected for a bridge component and a computed AF is compared to the acceptance criterion, and revisions to the analysis variables are made as necessary to achieve compliance. The distribution of the AF acceptance criterion among the exposed piers is generally based on the designer's judgment. In this study, the acceptance criterion is allocated to each pier using allocation weights based on the previous predictions. To determine the design impact lateral resistance of bridge components such pylon and pier, the numerical analysis is performed iteratively with the analysis variable of impact resistance ratio of pylon to pier. The design impact lateral resistance can vary greatly among the components of the same bridge, depending upon the waterway geometry, available water depth, bridge geometry, and vessel traffic characteristics. More researches on the allocation model of AF and the determination of impact resistance are required.

한정고장집단의 출하품질 보증을 위한 샘플링검사방식 설계

  • 권영일
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2002.06a
    • /
    • pp.275-279
    • /
    • 2002
  • A Bayesian acceptance sampling plan for limited failure populations are developed. We consider a situation where defective products have short lifetimes and non-defective ones never fail during the technological life of the products. An acceptance criterion which guarantees the out going quality of accepted products is derived using the prior information on the quality of lots submitted for inspection. Numerical examples are provided.

  • PDF

An Acceptance Sampling Plan for Products from Production Process with Variable Fraction Defective (불량률이 가변적인 공정으로부터 생산된 제품에 대한 수명시험 샘플링 검사방식 설계)

  • 권영일
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.2
    • /
    • pp.152-159
    • /
    • 2002
  • An acceptance sampling plan for products manufactured from a production process with variable fraction defective is developed. We consider a situation where defective products have short lifetimes and non-defective ones never fail during the technological life of the products. An acceptance criterion which guarantee the out going quality of accepted products is derived using the prior information on the quality of products. Numerical examples are provided.

Strain-based plastic instability acceptance criteria for ferritic steel safety class 1 nuclear components under level D service loads

  • Kim, Ji-Su;Lee, Han-Sang;Kim, Jong-Sung;Kim, Yun-Jae;Kim, Jin-Won
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.340-350
    • /
    • 2015
  • This paper proposes strain-based acceptance criteria for assessing plastic instability of the safety class 1 nuclear components made of ferritic steel during level D service loads. The strain-based criteria were proposed with two approaches: (1) a section average approach and (2) a critical location approach. Both approaches were based on the damage initiation point corresponding to the maximum load-carrying capability point instead of the fracture point via tensile tests and finite element analysis (FEA) for the notched specimen under uni-axial tensile loading. The two proposed criteria were reviewed from the viewpoint of design practice and philosophy to select a more appropriate criterion. As a result of the review, it was found that the section average approach is more appropriate than the critical location approach from the viewpoint of design practice and philosophy. Finally, the criterion based on the section average approach was applied to a simplified reactor pressure vessel (RPV) outlet nozzle subject to SSE loads. The application shows that the strain-based acceptance criteria can consider cumulative damages caused by the sequential loads unlike the stress-based acceptance criteria and can reduce the overconservatism of the stress-based acceptance criteria, which often occurs for level D service loads.

Design Strength of Bridge Piers against Ship Collision (교각의 선박충돌 설계강도)

  • Lee Seong-Lo;Bae Yong-Gwi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.659-662
    • /
    • 2004
  • An analysis of the AF is performed for each bridge pier exposed to ship collision. From this analysis, the impact lateral resistance can be determined for each pier. The bridge pier impact resistance is selected using a probability-based analysis procedure in which the predicted AF, from the ship collision risk assessment is compared to an acceptance criterion. In this study, the acceptance criterion is allocated to each pier using allocation weights based on the previous predictions. To determine the design impact lateral resistance of bridge components such pylon and pier, the numerical analysis is performed iteratively with the analysis variable of impact resistance ratio of pylon to pier. The design impact lateral resistance can vary greatly among the components of the same bridge, depending upon the waterway geometry, available water depth, bridge geometry, and vessel traffic characteristics.

  • PDF

A Study on the Establishment of Management Criteria for Underwater Noise (수중소음 관리 기준 설정을 위한 소고)

  • Lim, Dae-Kyu;Shin, Young-Cheol;Jun, Yang-Bae
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.119-132
    • /
    • 2010
  • There are many dispute with a construction due to such environment problem as vibration and noise. Generally, we have a standard for acceptance level in land. But we have not a sufficient standard for acceptance level or guide line in underwater sound. In other countries, a acceptance level or guide line in underwater sound has been suggested. Especially the management criterion of underwater noise for fish has bee suggested using the measurement data (peak pressure, rms, energy and SEL) by a hydrophone. In Korea, there is no management criterion of underwater noise for fish. This study suggested the management criteria of underwater noise for fish based on the measured data by a hydrophone.

Ultrasonic Test Criterion for the Explosively Welded Fe-Naval Brass Bonding Quality (초음파법에 의한 폭발접합 이종금속 접합품질 판정레벨 설정에 관한 연구)

  • 장영권;백영남
    • Journal of Welding and Joining
    • /
    • v.19 no.1
    • /
    • pp.40-48
    • /
    • 2001
  • An ultrasonic test method, as a nondestructive test is applied to ensure the clad interface quality assessment. According to the reference codes and standards, not only korea Industrial Standard(KS) but also American Society for Testing and Materials (ASTM) Standard, ultrasonic examination procedures use the pulse-echo, A-scan, back reflection signal drop method and/or side drilled reference hole used to establish the acceptance criteria of clad material test. But the variety of bonding materials and sizes makes it difficult to produce the reference blocks, or thus the criteria. In order to overcome these practical difficulties, new ultrasonic testing criterion is suggested. In this new method, the theoretical interface reflection signal amplitude level is calculated and suggested as an acceptance criteria with the back reflection signal set to 100% FSH(Full Screen Height) which is based on acoustic impedance mismatch at the clad interface for the explosive clad ultrasonic inspection. Applicability of suggested criterion, for the explosive clad Fe-Naval Brass with different bonding quality is confirmed to the pre-existed KS and ASTM specifications and verified by using SEM (Seanning Electron Microscope) micrograph. The results obtained by the suggested method is more conservative than the results according to the KS B 0234 and ASTM A 578 specifications The suggested method could be applicable to any other combination of explosive clad ultrasonic inspection.

  • PDF

Considering Aspects for the Revision of Current Bioequivalence Guideline (국내 생물학적 동등성 시험 기준 개정 방향)

  • Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.4
    • /
    • pp.233-242
    • /
    • 2009
  • Bioequivalence (BE) studies provide important information in the overall set of data that ensure the availability of safe and effective medicines to patients and practitioners. Thus its determination of proper criterion for assessing BE is very important. BE is frequently expressed or measured by estimating area under the plasma concentration-time curve (AUC) and maximum concentration ($C_{max}$) that are reflective of systemic exposure. In all countries except Canada, the acceptance criteria of BE is that the 90% confidence interval of difference in the average values of logarithmic AUC and $C_{max}$ between test and reference products is within the acceptable range of log(0.8) ${\sim}$ log(1.25). In Canada, unlike other countries, point estimation instead of applying 90% confidence interval is applied to assess $C_{max}$ which is, in essence, more variable than AUC. We also compared other parts of BE guidelines which include a fed study, average BE (ABE), scaled-ABE, population BE (PBE), individual BE (IBE), dropout & withdrawal, sampling frequency & time and number of subjects. This article reviews the most recent BE guidelines of Korea, USA, Europe, Canada and Japan, highlighting the differences focused on Korean BE guidelines compared to other countries. It will help us to revise BE guideline of Korea reflecting international trends. Finally, it is strongly recommended that the extended acceptance criterion for the highly variable drug among all the considering aspects for the revision of current BE guideline has to be adopted into Korea BE guideline in the nearest future.