• Title/Summary/Keyword: Accelerometer Board

Search Result 23, Processing Time 0.021 seconds

Studies on The Free Vibrational Properties of Traditional and Replaceable Species for Sounding Board (향판용(響板用) 관행수종(慣行樹種)과 대체가능수종(代替可能樹種)의 자유진동적(自由振動的) 성질(性質)에 관한 연구(硏究))

  • Kang, Wook;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.48-64
    • /
    • 1988
  • This study was carried out to investigate the free vibrational properties of traditional and replaceable species for sounding board, using piezoelectrical accelerometer and signal analyzer. In the study, the frequency equations of free-free beam carrying a concentrated mass in the transverse vibration and of free-mass beam in the longitudinal vibration were used. The results obtained were as follows. 1. Average values of dynamic modulus of rigidity of Korean commercial species measured were as follows. Paulownia tomatosa (Thunb.) Steudel: $5.590\times10^9\;dyne/cm^2$ Tilia amurensis Rupr.: $5.414\times10^9\;dyne/cm^2$ Macckia amurensis Rupr.: $10.044\times10^9\;dyne/cm^2$ Fraxinus mandshurica Rupr.: $8.876\times10^9\;dyne/cm^2$ Ulmus davidiana var.japonica Nakai: $8.677\times10^9\;dyne/cm^2$ Pinus rigida Miller: $6.33\times10^9\;dyne/cm^2$ Fraxinus rhynchophylla Hance: $4.666\times10^9\;dyne/cm^2$ 2. The ratio of dynamic transverse Young's modulus to dynamic modulus of rigidity, $E_T/G_{LT}$, was 24.922 for Fraxinus rhynchophylla Hance, which was the highest, 7.317 for Paulownia tomentosa (Thunb.) Steudel, which was the lowest among Korean commercial species measured. 3. The value of longitudinal dynamic Young's modulus was about 3.7% and 19.8%, respectively, higher than those of transverse dynamic and static Young's modulus. The value of transverse dynamic Young's modulus was about 15.5% higher than that of static Young's modulus. 4. Predicted value of MOR in terms of correlation coefficient by transverse dynamic Young's modulus was slightly higher than that of static Young's modulus, but no significance was found out. 5. Transverse dynamic Youne's modulus was $(2.002\pm0.288)\times10^{11}\;dyne/cm^2$ for Fraxinus mandshurlca Rupr., which was the highest, $(0.601\pm0.100)\times10^{11}\;dyne/cm^2$ for Paulownia tomentosa (Thunb.) Steudel, which was the lowest among Korean commercial species measured. The sound velocity of sitka spruce was 5,685 m/sec, which was the highest. 6. Internal friction of Paulownia tomentosa (Thunb.) Steudel was shown the lowest value among Korean commercial species, $(8.795\pm1.795)\times10^{-3}$, but was higher than that of sitka spruce, $(7.331\pm0.991)\times10^{-3}$. Internal friction was shown negative correlation with density and dynamic Young's modulus, respectively. 7. K value was affected largely by internal friction and was the highest, $2.225\times10^8$ for Paulownia tomentosa (Thunb.) Steudel and was the lowest, $0.550\times10^8$ for Fraxinus rhynchophylla Hance. K value of Paulownia tomentosa (Thunb.) Steudel was higher than that of sitka spruce and K values of melapi and cottonwood, which have been considered to be replaceable species with sitka spruce in the piano industry, were lower than those of Paulownia tomentosa (Thunb.) Steudel and mill amurensis Rupr.

  • PDF

Trunk Stabilization Measurements Using the Nintendo Wii (닌텐도 위를 활용한 흉부 흔들림의 자세 안정성 측정)

  • Yang, Juyeong;Yoo, Jaeha;Kim, Dongyon;Park, Junmo;Kim, Soochan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.7
    • /
    • pp.239-247
    • /
    • 2014
  • The CTSIB (Clinical Test of Sensory Integration on Balance) using high sensitive pressure sensors is normally used to assess the sense of balance in hospital. It takes an objective measurement of the amount of sway that occurs in the body trunk by observing the change in the center of pressure (CoP) on the foot at the upright posture. In this paper, we would like to propose method to easily measure trunk sway in home. Although the Wii balance board(WBB) is used for games, it can measures the center of pressure, which is highly correlated. The Wii remote controller(WRC) is inexpensive compared to the WBB, but it has problems with estimation of trunk sway because it can't measure pressure directly like WBB. We collected data from 10 normal subjects (5 males, 5 females) from two devices in order to compare the CoP from WBB and the center of mass (CoM) from WRC. The results of WRC and WBB was similar when the data were analyzed by the convex hull and ellipse area.

A comparative study of cavitation inception of naval ship's propeller using on-board noise and vibration signals (선체 부착 소음/진동 센서를 이용한 함정 추진기 캐비테이션 초생 분석 비교 연구)

  • Hongseok Jeong;Hanshin Seol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.3
    • /
    • pp.243-249
    • /
    • 2023
  • The occurrence of cavitation on the propeller is directly linked to the naval ship's survivability, and it is necessary to design a propeller shape that delays the cavitation inception. However, the propeller cavitation can occur under various operating conditions, thus it is important to identify whether the propeller cavitation exists during operation as well as in the design phase. To this end, it is necessary to use noise or vibration signals on board to monitor the cavitation inception. In this study, a hydrophone and an accelerometer were installed on the ship hull right above the propeller to compare the performance of analyzing cavitation inception between acoustic and vibration signals. Also, a high speed camera was used to visually observe the occurrence of cavitation through an observation window. The measured results showed that the spectral shapes between acoustic and vibration signals were different, but the level increases at each frequency band and the overall level of the frequency band from 1 kHz to 10 kHz showed a similar tendency. The Detection of Envelope Modulation On Noise (DEMON) analysis also showed similar results for both acoustic and vibration signals, confirming that both hydrophones and accelerometers can be utilized in the analysis of cavitation inception.