• Title/Summary/Keyword: Accelerator-driven sub-critical system

Search Result 8, Processing Time 0.024 seconds

Beam-target configurations and robustness performance of the tungsten granular flow spallation target for an Accelerator-Driven Sub-critical system

  • Cai, Han-Jie;Jia, Huan;Qi, Xin;Lin, Ping;Zhang, Sheng;Tian, Yuan;Qin, Yuanshuai;Zhang, Xunchao;Yang, Lei;He, Yuan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2650-2659
    • /
    • 2022
  • The dense granular flow spallation target is a new target concept proposed for an Accelerator-Driven Sub-critical (ADS) system. In this paper, the beam-target configurations of a tungsten granular flow target for the ADS with a thermal power of 1 GW is explored. The beam profile options using different scanning methods are discussed. The critical geometry parameters are adjusted to investigate the performance of the granular target from the aspects of neutron efficiency, stability and temperature distribution in target medium. To figure out how the target under accident conditions would behave, different clogging conditions are induced in the simulation. The dynamic processes are analyzed and some important parameters such as abnormal temperature rise and beam cutoff time window are obtained. The response of the sub-critical reactor to a clogging accident is also investigated. It is indicated that the monitoring of the granular flow by the neutron detectors in the sub-critical core will be effective.

Conceptual Design for Accelerator-Driven Sodium-Cooled Sub-critical Transmutation Reactors using Scale Laws and Integrated Code System

  • Lee, Kwang-Gu;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.660-665
    • /
    • 1998
  • The feasibility study on conceptual design methodology for accelerator-driven sodium-cooled sub-critical transmutation reactors has been conducted to optimize the design parameters from the scale laws and validates reactor performance with the integrated code system. A 1000 MWth sodium-cooled sub-critical transmutation reactor has been scale and verified through the methodology in this paper, which is referred to advanced Liquid Metal Reactor (ALMR). a Pb-Bi target material and a partitioned fuel are the liquid phases, and they are cooled by the circulation of secondary Pb-Bi coolant and by primary sodium coolant, respectively. Overall key design parameters are generated from the scale laws and they are improved and validated by the intergrated code system. Intergrated Code System (ICS) consist of LAHET, HMCNP, ORIGEN2, and COMMIX codes and some files. Through ICS the target region, the core region, and thermal-hydraulic related are analyzed once-through. Results of conceptual design are attached in this paper.

  • PDF

Reactor Physics Study Related to Subcriticality of Accelerator Driven System By AESJ/JAERl Working Party

  • Iwasaki, Tomohiko
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.05a
    • /
    • pp.66-66
    • /
    • 2002
  • Under Atomic Energy Society of Japan (AESJ) and Japan Atomic Energy Research Institute (JAERO, a Working Party on Reactor Physics of Accelerator-Driven System (ADS-WP) has been set since March 1999 to review and investigate special subjects related to reactor physics research of Accelerator-Driven System (ADS). In the ADSWP, the extensive and aggressive activity is being made by 25 professional members in the field of reactor physics in Japan. The ADS is now studying three subjects related to subcriticality of ADS; (1) calculation accuracy of sub criticality on ADS, (2) critical safety issues of ADS, and (3) theoretical review of subcriticality and its measurement methods. This paper describes two topics related to the subjects (1) and (2); one is an analysis of maximum reactivity potentially inserted to a subcritical core and the other is a benchmark proposal for checking calculation accuracy of sub criticality on ADS. The full specification of the calculation benchmark will be supplied by June 2002. Researchers from overseas, especially from Korea, are welcome to join this benchmark

  • PDF

Sub-Critical Nuclear Reactor Based on FFAG-Accelerator

  • Lee, Tae-Yeon;Gang, Heung-Sik;Lee, Hui-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.214-214
    • /
    • 2012
  • 최근 일본에서 일어난 지진과 쓰나미에 의한 원전 사고는 원자력의 안전성에 대한 매우 심각한 의문을 던져주었으며, 어떠한 경우에도 안전한 원자로의 필요성이 크게 대두하였다. 본 발표는 그러한 원자로로, 이러한 재난이 닥쳤을 때 핵분열 반응이 즉시 중지되는 가속기구동 원자로(accelerator-driven system)를 제시한다. 이것은 원자로를 임계치 아래로(sub-critical) 유지한 상태에서 외부에서 가속기를 이용하여 필요한 중성자를 공급하여 핵분열 반응을 유지하는 원자로로서, 재난 발생 시 가속기가 즉시 중지됨으로서 원자로 역시 즉각적으로 중지된다. 본 발표에서 그 동안 아이디어로 존재하던 이것의 타당성, 현실성, 전망 등에 대하여 설명한다.

  • PDF

The mechanical design and fabrication of 162.5 MHz buncher for China accelerator driven sub-critical system injector II

  • Niu, Haihua;Li, Youtang;He, Yuan;Zhang, Bin;Huang, Shichun;Yuan, Chenzhang;Jia, Huan;Zhang, Shenghu
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.1071-1078
    • /
    • 2017
  • A buncher is one of the main pieces of equipment in the medium energy beam transport line (MEBT) for China accelerator driven sub-critical system (C-ADS) Injector II. To focus the beam longitudinally and match the beam for the acceptance of the superconducting linac section, two room temperature quarter wave resonator (QWR) bunchers with frequency of 162.5 MHz have been designed as parts of the MEBT. According to the beam transmission matching of the MEBT and the geometric parameters requirements of bunchers, the unique mechanical structure and the main processing technology of buncher cavities and their couplers and tuners are described in this paper. The fabrication of bunchers and their parts have been completed and tested at high power, the test results agree well with the design requirements. These bunchers work well for about two years in Institute of Modern Physics, Chinese Academy of Sciences.

Power control of CiADS core with the intensity of the proton beam

  • Yin, Kai;Ma, Wenjing;Cui, Wenjuan;He, Zhiyong;Li, Xinxin;Dang, Shiwu;Yang, Feng;Guo, Yuhui;Duan, Limin;Li, Meng;Hou, Yikai
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1253-1260
    • /
    • 2022
  • This paper reports the control method for the core power of the China initiative Accelerator Driven System (CiADS) facility. In the CiADS facility, an intense external neutron source provided by a proton accelerator coupled to a spallation target is used to drive a sub-critical reactor. Without any control rod inside the sub-critical reactor, the core power is controlled by adjusting the proton beam intensity. In order to continuously change the beam intensity, an adjustable aperture is considered to be used at the Low Energy Beam Transport (LEBT) line of the accelerator. The aperture size is adjusted based on the Proportional Integral Derivative (PID) controllers, by comparing either the setting beam intensity or the setting core power with the measured value. To evaluate the proposed control method, a CiADS core model is built based on the point reactor kinetics model with six delayed neutron groups. The simulations based on the CiADS core model have indicated that the core power can be controlled stably by adjusting the aperture size. The response time in the adjustment of the core power depends mainly on the adjustment time of the beam intensity.

The Summary of Researches on ADS in China

  • Haihong Xia;Zhixiang Zhao;Jigen Li;Yongqian Shi;Yinlu Han;Shengyun Zhu;Yongli Xu;Xialing Guan;Shinian Fu;Baoqun Cui
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.76-85
    • /
    • 2005
  • The conceptual study of Accelerator Driven System (ADS) had lasted for about five years and ended in 1999 in China. As one project of 'the major state basic research program (973)' in energy domain, which is sponsored by the China Ministry of Science and Technology (MOST), a five years program of basic research for ADS physics and related technology has been launched since 2000 and passed national review last month. CIAE (China Institute of Atomic Energy), IHEP (Institute of High Energy Physics), PKU-IHIP (Institute of Heavy Ion Physics in Peking University) and other institutions are jointly carrying on the research. The research activities are focused on HPPA physics and technology, reactor physics of external source driven sub-critical assembly, nuclear data base and material study. For HPPA, a high current injector consisting of an ECR ion source, LEBT and a RFQ accelerating structure of 3.5MeV has been built. In reactor physics study, a series of neutron multiplication experimental study has been carried out and is being carrying on. The VENUS facility has been constructed as the basic experimental platform for the neutronics study in ADS blanket. It's a zero power sub-critical neutron multiplying assembly driven by external neutron produced by a pulsed neutron generator. The theoretical, experimental and simulation study on nuclear data, material properties and nuclear fuel circulation related to ADS is carrying on to provide the database for ADS system analysis. The main results on ADS related researches will be reported.

  • PDF

Design, fabrication and test of a taper-type half-wave superconducting cavity with the optimal beta of 0.15 at IMP

  • Yue, Weiming;Zhang, Shengxue;Li, Chunlong;Jiang, Tiancai;Liu, Lubei;Wang, Ruoxu;Huang, Yulu;Tan, Teng;Guo, Hao;Zaplatin, Evgeny;Xiong, Pingran;Wu, Andong;Wang, Fengfeng;Zhang, Shenghu;Huang, Shichun;He, Yuan;Yao, Zeen;Zhao, Hongwei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1777-1783
    • /
    • 2020
  • As a part of R&D work for the high intensity proton linac of China Accelerator Driven Sub-critical System project, a superconducting half-wave cavity with a frequency of 162.5 MHz and an optimal beta of 0.15 (HWR015) has been developed at Institute of Modern Physics (IMP), Chinese Academy of Sciences. In this paper, the design and test results will be described in detail. We introduced a new stiffening strategy for the HWR cavity, the simulation results show that the cavity has much lower frequency sensitivity coefficient (df/dp), Lorentz force detuning coefficient (KL), and can achieve more stable mechanical properties. The performance of the HWR cavity operated in cryostat will be also reported.