• 제목/요약/키워드: Accelerator mass spectrometry

검색결과 27건 처리시간 0.032초

Study on production process of graphite for biological applications of 14C-accelerator mass spectrometry

  • Ha, Yeong Su;Kim, Kye-Ryung;Cho, Yong-Sub;Choe, Kyumin;Kang, Chaewon
    • 대한방사성의약품학회지
    • /
    • 제6권1호
    • /
    • pp.20-26
    • /
    • 2020
  • Accelerator mass spectrometry (AMS) is a powerful detection technique with the exquisite sensitivity and high precision compared with other traditional analytical techniques. Accelerator mass spectrometry can be widely applied in the technique of radiocarbon dating in the fields of archeology, geology and oceanography. The ability of accelerator mass spectrometry to measure rare 14C concentrations in microgram and even sub-microgram amounts suggests that extension of 14C-accelerator mass spectrometry to biomedical field is a natural and attractive application of the technology. Drug development processes are costly, risky, and time consuming. However, the use of 14C-accelerator mass spectrometry allows absorption, distribution, metabolism and excretion (ADME) studies easier to understand pharmacokinetics of drug candidates. Over the last few decades, accelerator mass spectrometry and its applications to preclinical/clinical trials have significantly increased. For accelerator mass spectrometry analysis of biological samples, graphitization processes of samples are important. In this paper, we present a detailed sample preparation procedure to apply to graphitization of biological samples for accelerator mass spectrometry.

가속기 질량 분광분석법을 이용한 환경 연구 (Accelerator Mass Spectrometry in Environmental Research)

  • 문창범
    • 한국대기환경학회지
    • /
    • 제16권4호
    • /
    • pp.421-428
    • /
    • 2000
  • Accelerator Mass Spectrometry (AMS) is presented for the applications to the environmental research. Traditionally the radiocarbon (14C) measurements have been made for the purpose of dating the archaeological and geological samples. 14C measurements using AMS however have become the more useful methods for the study of environmental science such as antropogenic modification of atmosphere and the determination of mixing ratios of fossil and biomass products. Such 14C AMS measurements have been extended to the discovery of new chemical tracers for investigations of sources of excessive contributions of CO2, CO, CH4 and other carbon-bearing molecules in the atmosphere.

  • PDF

가속질량분석기(Accelerator mass spectrometry, AMS)와 극미량 $^{14}C$-동위원소를 이용한 혁신적 임상시험개발동향 (Trends of Innovative Clinical Drug Development using AMS (Accelerator Mass Spectrometry) and $^{14}C$-micro Tracer)

  • 조경희;이희주;최형식;이경률;;신영근
    • 약학회지
    • /
    • 제57권6호
    • /
    • pp.412-419
    • /
    • 2013
  • Drug discovery and development processes are time consuming and costly endeavors. It has been reported that on average it takes 10 to 15 years and costs more than $ 1billion to bring a molecule from discovery to market. Compounds fail for various reasons but one of the significant reasons that accounts for failures in clinical trials is poor prediction/understanding of pharmacokinetics and drug metabolism in human. In an effort to improve the number of compounds that exhibit optimal absorption, distribution, metabolism, elimination (ADME), and pharmacokinetic properties in human, drug metabolism, pharmacokinetic scientists have been continually developing new technologies and compound screening strategies. Over the last few years, accelerator mass spectrometry (AMS) and its applications to preclinical/clinical pharmacokinetics and ADME studies have significantly increased, particularly for new chemical/biological entities that are difficult to support with conventional radiolabel studies. In this review, the application of AMS for micro-dosing, micro-tracer absolute bioavailability, mass balance and metabolite profiling studies will be discussed.

가속기 질량 분광분석법을 이용한 대기 환경 연구 (Accelerator Mass Spectrometry in Atmospheric Environment)

  • 문창범;채수조;정준오;정진도
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.103-107
    • /
    • 1999
  • 가속기 질량분광분석법(Accelerator Mass Spectrometry; AMS)은 동위원소 분석에 있어 초정밀 질량 분석 기술에 속한다. 시료(Samples)의 원자를 이온화 시켜 가속시키고, 에너지, 운동량 그리고 전하 상태를 분석하여 최종 얻고자 하는 원자핵의 동위원소, 예를 들어 탄소-14$^{14)C$),의 수를 정확하게 측정하는 분광분석 기술이다. 본 논문을 통하여 AMS를 소개하고 대기 환경 연구에 AMS가 어떻게 응용될 수 있는지 살펴 보기로 한다.(중략)

  • PDF

Development of magnetic field measurement system for AMS cyclotron

  • Ho Namgoong;Hyojeong Choi;Mitra Ghergherehchi;Donghyup Ha;Mustafa Mumyapan;Jong-Seo Chai;Jongchul Lee;Hoseung Song
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.3114-3120
    • /
    • 2023
  • A high-accuracy magnetic field measurement device based on a cyclotron is being developed for accelerator mass spectrometry (AMS). In this study, a magnetic field measurement device consisting of a Hall probe sensor, piezo-motor, and step motor was developed to measure the magnetic field of the AMS cyclotron magnet. The Hall probe sensor was calibrated to achieve positional accuracy by using polar coordinates. The measurement results between the ratchet gear and piezo-motor, which are the instruments used for driving the measurement device, were analyzed. The measurement result of the device with a piezo-motor exhibits a difference of 5 Gauss (0.04%) as compared with the simulation result.

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

Direct Writing Lithography Technique for Semiconductor Fabrication Process Using Proton Beam

  • Kim, Kwan Do
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.38-41
    • /
    • 2019
  • Proton beam writing is a direct writing lithography technique for semiconductor fabrication process. The advantage of this technique is that the proton beam does not scatter as they travel through the matter and therefore maintain a straight path as they penetrate into the resist. The experiment has been carried out at Accelerator Mass Spectrometry facility. The focused proton beam with the fluence of $100nC/mm^2$ was exposed on the PMMA coated silicon sample to make a pattern on a photo resist. The results show the potential of proton beam writing as an effective way to produce semiconductor fabrication process.

Lower the Detection Limits of Accelerator Mass Spectrometry

  • ;송종한;김준곤;김재열;오종주;김종찬
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.243-244
    • /
    • 2013
  • Over the past 15 years, several groups have incorporated radio-frequency quadrupole (RFQ) based instruments before the accelerator in accelerator mass spectrometry (AMS) systems for ion-gas interactions at low kinetic energy (<40 eV). Most AMS systems arebased on a tandem accelerator, which requires negative ions at injection. Typically, AMS sensitivity abundance ratios for radioactive-to-stable isotope are limited to Xr/Xs >10^-15, and the range of isotopes that can be analyzed is limited because of theneed to produce rather large negative ion beams and the presence of atomic isobaric interferences after stripping. The potential of using low-kinetic energy ion-gas interactions for isobar suppression before the accelerator has been demonstrated for several negative ion isobar systems with a prototype RFQ system incorporated into the AMS system at IsoTrace Laboratory, Canada (Ontario, Toronto). Requisite for any such RFQ system applied to very rare isotope analysis is large transmission of the analyte ion. This requires proper phase-space matching between the RFQ acceptance and the ion beam phase space (e.g. 35 keV, ${\varphi}3mm$, +-35 mrad), and the ability to control the average ion energy during interactions with the gas. A segmented RFQ instrument is currently being designed at Korea Institute for Science and Technology (한국과학기술연구원, KIST). It will consist of: a) an initial static voltage electrode deceleration region, to lower the ion energy from 35 keV down to <40 eV at injection into the first RFQ segment; b) the segmented quadrupole ion-gas interaction region; c) a static voltage electrode re-acceleration region for ion injection into a tandem accelerator. Design considerations and modeling will be discussed. This system should greatly lower the detection limits of the 6 MV AMS system currently being commissioned at KIST. As an example, current detection sensitivity of 41Ca/Ca is limited to the order of 10^-15 while the 41Ca/Ca abundance in modern samples is typically 41Ca/Ca~10^-14 - 10^-15. The major atomic isobaric interference in AMS is 41K. Proof-of-principal work at IsoTrace Lab. has demonstrated that a properly designed system can achieve a relative suppression of KF3-/41CaF3- >4 orders of magnitude while maintaining very high transmission of the 41CaF3- ion. This would lower the 41Ca detection limits of the KIST AMS system to at least 41Ca/Ca~10^-19. As Ca is found in bones and shells, this would potentially allow direct dating of valuable anthropological archives and archives relevant to our understanding of the most pronounced climate change events over the past million years that cannot be directly dated with the presently accessible isotopes.

  • PDF

열중량 분석기와 질량가속기를 이용한 목재·플라스틱 복합재의 목질섬유함량 분석 (Determination of Wood Flour Content in WPC Through Thermogravimetic Analysis and Accelerator Mass Spectrometry)

  • 권재경;이단비;조혜정;전상진;최돈하;이선영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권5호
    • /
    • pp.572-579
    • /
    • 2017
  • WPC 내 목질섬유 함량 분석은 신뢰도 높은 목재 플라스틱 복합재(WPC) 소비시장 형성을 위해 상당히 중요하다. 본 연구에서는 polypropylene과 목질섬유를 복합화한 단순 WPC 배합 조건에서 WPC 내 목질섬유 함량에 대한 분석을 TGA를 이용한 열분석 방법과 AMS를 이용한 바이오 탄소 함량 분석 방법을 통해 진행하였다. TGA를 통한 열분해 분석법은 $5^{\circ}C/min$의 승온속도로 고분자 PP의 최대 미분 온도를 이용하여 신뢰도 높은 WPC 내 목질섬유 함량에 관한 검량선을 얻을 수 있었다. TGA와 AMS의 분석 방법 비교에 있어서는, 바이오 탄소 함량을 이용하는 AMS 분석법이 더 높은 신뢰성을 보여주었다.