• 제목/요약/키워드: Acceleration time history response

검색결과 170건 처리시간 0.026초

Spectral element method in the analysis of vibrations of overhead transmission line in damping environment

  • Dutkiewicz, Maciej;Machado, Marcela
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.291-303
    • /
    • 2019
  • In the paper the analysis of natural vibrations of the transmission line with use of spectral elements and the laboratory experiments is performed. The purpose of the investigation is to analyze the natural vibrations of the transmission line and compare with the results obtained in the numerical simulations. Particular attention is paid to the hysteretic and aerodynamic damping analysis. Sensitivity of the wave number is performed for changing of the tension force, as well as for the different damping parameters. The numerical model is made using the Spectral Element Method. In the spectral model, for various parameters of stiffness, damping and tension force, the system response is checked and compared with the results of the accelerations obtained in the measurements. A frequency response functions (FRF) are calculated. The credibility of the model is assessed through a validation process carried out by comparing graphical plots of FRF and time history analysis and numerical values expressing differences in acceleration amplitude (MSG), phase angle differences (PSG) and differences in acceleration and phase angle total (CSG) values. The next aspect constituting the purpose of this paper is to present the wide possibilities of modelling and simulation of slender conductors using the Spectral Element Method. The obtained results show good accuracy in the range of both experimental measurements as well as simulation analysis. The paper emphasizes the ease with which the sensitivity of the conductor and its response to changes in density of spectral mesh division, tensile strength or material damping can be studied.

해석(解析)모델의 구조변수(構造變數) 변동(變動)이 동적응답에 미치는 영향(影響) (Effects of Structural Parameter Variations on Dynamic Responses)

  • 박형기;임부영
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.59-67
    • /
    • 1993
  • 부분구조법(部分構造法)으로 프리스트레스드 콘크리트 원자로격납건물(原子爐格納建物)의 지진에 대한 확률위험도분석이나 내진 안전여유평가시 상부구조에 관한 입력자료(入力資料)가 되는 구조물(構造物)의 고유전동수와 구조물 상부에서의 최대가 속도값의 구조변수(構造變數)에 대한 변동성이 연구되었다. 본 연구는 먼저 구조모델의 고유진동수에 가장 큰 영향을 미치는 구조변수를 결정하기 위하여 각 구조변수(構造變數)의 상대적(相對的) 민감도(敏感度)를 분석(分析)하였고, 각 변수의 결정에 포함될 수 있는 불확실성(不確實性)의 정도를 고려하여 Monte Carlo 수치모형실험을 수행하였다. 최대 가속도값의 변화는 직접적분(直接積分)에 의한 시간이력곡선법으로 분석되었다. 연구결과로 첫번째모드의 고유 진동수와 건물 정상부의 최대가속도값은 각 변수중 탄생계수의 영향을 가장 크게 받으며, 결정론적 방법으로 구한 값과 비교할 때 확률론적 방법으로 구한 값(평균+표준편차)은 (+)12% 정도 변함을 알 수 있다. 또한 휨강성의 불확실성을 고려하면 동적응답은 (-)4%~(+)14% 정도 달라진다.

  • PDF

Influence of soil model complexity on the seismic response of shallow foundations

  • Alzabeebee, Saif
    • Geomechanics and Engineering
    • /
    • 제24권2호
    • /
    • pp.193-203
    • /
    • 2021
  • The time-history finite element analysis is usually used to evaluate the seismic response of shallow foundations. However, the literature lacks studies on the influence of the soil constitutive model complexity on the seismic response of shallow foundations. This study, thus, aims to fill this gap by investigating the seismic response of shallow foundation resting on dry silica sand using the linear elastic (LE) model, elastic-perfectly-plastic (EPP) model, and hardening soil with small strain stiffness (HS small) model. These models have been used because it is intended to compare the results of a soil constitutive model that accurately captures the seismic response of the soil-structure interaction problems (which is the HS small model) with simpler models (the LE and EPP models) that are routinely used by practitioners in geotechnical designs. The results showed that the LE model produces a very small seismic settlement value which is approximately equal to zero. The EPP model predicts a seismic settlement higher than that produced using the HS small model for earthquakes with a peak ground acceleration (PGA) lower than 0.25 g for a relative density of 45% and 0.40 g for a relative density of 70%. However, the HS small model predicts a seismic settlement higher than the EPP model beyond the aforementioned PGA values with the difference between both models increases as the PGA rises. The results also showed that the LE and EPP models predict similar trend and magnitude of the acceleration-time relationship directly below the foundation, which was different than that predicted using the HS small model. The results reported in this paper provide a useful benchmark for future numerical studies on the response of shallow foundations subjected to seismic shake.

지진가속도 계측기를 이용한 건축물의 긴급 안전성 평가 알고리즘 개발에 대한 연구 (A Study on the Development of a Rapid Safety Assessment System for Buildings Using Seismic Accelerometers)

  • 정성훈;장원석;박병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.161-170
    • /
    • 2020
  • 본 연구에서는 공공 시설물을 대상으로 설치된 지진가속도 계측 시스템의 운영 효율성 개선을 위하여 지진 이벤트 신호 변환 및 처리 알고리즘을 개발하였다. 더불어 처리된 지진 가속도 시간이력의 분석을 통해 건축물의 안전성을 평가할 수 있는 평가 방법과 평가 기준을 제안하였으며, 테스트베드 건축물에 적용하여 그 작동과 활용성을 검증하였다. 이를 통해 지진 이벤트 계측자료의 분석 정확성을 확보하고, 지진재해 상황에서 재난 대응의 방향과 우선순위 판단을 위한 의사결정 지원자료로 활용할 수 있을 것으로 판단된다.

Effect of the incoherent earthquake motion on responses of seismically isolated nuclear power plant structure

  • Ahmed, Kaiser;Kim, Dookie;Lee, Sang H.
    • Earthquakes and Structures
    • /
    • 제14권1호
    • /
    • pp.33-44
    • /
    • 2018
  • Base-isolated nuclear power plant (BI-NPP) structures are founded on expanded basemat as a flexible floating nuclear island, are still lacking the recommendation of the consideration of incoherent motion effect. The effect of incoherent earthquake motion on the seismic response of BI-NPP structure has been investigated herein. The incoherency of the ground motions is applied by using an isotropic frequency-dependent spatial correlation function to perform the conditional simulation of the reference design spectrum compatible ground motion in time domain. Time history analysis of two structural models with 486 and 5 equivalent lead plug rubber bearing (LRB) base-isolators have been done under uniform excitation and multiple point excitation. two different cases have been considered: 1) Incoherent motion generated for soft soil and 2) Incoherent motion generated for hard rock soil. The results show that the incoherent motions reduce acceleration and the lateral displacement responses and the reduction is noticeable at soft soil site and higher frequencies.

지진격리 구조물의 지진모니터링 시스템 개발 (The Development of Seismic Monitoring for a Base-Isolated Building System)

  • 김성훈;조대승;박해동;김두훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.247-251
    • /
    • 2001
  • Nowadays, base isolation systems such as lead-rubber bearing, elastomer bearing and sliding bearing have been installed to the various structures to prevent the disaster from seismic. The performance of base isolation system have been well proved by model-scale experiments and numerical analysis. However. the seismic response data measured at real large base-isolated structures is still insufficient. This paper presents a seismic monitoring system, acquiring real-time acceleration signals up to 32 channels, displaying time history and spectrum of the signals, storing the acquired data at a PC hard disk, and replaying the saved data. Moreover, the system can be operated without any limitation for monitoring period by automatic management of stored data file. The developed system has been installed at a real base-isolated building using lead-rubber bearings and we expect its seismic response data with ground motion signal can be well licquired in case of earthquake occurrence.

  • PDF

Parametric study on dynamic behavior of rectangular concrete storage tanks

  • Yazdanian, Mohsen;Fu, Feng
    • Coupled systems mechanics
    • /
    • 제6권2호
    • /
    • pp.189-206
    • /
    • 2017
  • Tanks are used to store a wide variety of liquids such as oil, gasoline and water. It is reported that, a large number of tanks have been damaged during severe earthquakes. Therefore, understanding their behavior under earthquake is an important subject for structural engineers. In this paper, a comprehensive study is presented on dynamic response of tanks. A parametric study has been completed on the rectangular storage tanks with aid of finite element method (FEM). Various parameters are investigated, such as; liquid height, density and earthquake with different peak ground acceleration (PGA). When investigating these parameters, modal and time history method is used. Six different earthquake records are used for time history analysis. The analysis results show that when the PGA increases by 10.7 times, the maximum displacements, stress, sloshing and base shear increase by 11.4, 22.6, 5.46 and 17.8 times, respectively and when the liquid height increases by two times, the absolute maximum values of stress, displacements, base shear and sloshing increase 1.65, 2.04, 2.05 and 1.34. Furthermore, values of sloshing increase with decrease in density.

Effect of seismic pounding on buildings isolated by triple friction pendulum bearing

  • Amiri, Gholamreza Ghodrati;Shakouri, Ayoub;Veismoradi, Sajad;Namiranian, Pejman
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.35-45
    • /
    • 2017
  • The current paper investigates the effect of the seismic pounding of neighboring buildings on the response of structures isolated by Triple Friction Pendulum Bearing (TFPB). To this end, a symmetric three-dimensional single story building is modeled for analysis with two specified levels of top deck and base deck, to capture the seismic response of the base isolators and building's roof. Linear elastic springs with different level of gaps are employed to calculate the impact between the buildings. Nonlinear Dynamic Time History Analyses (NDTHA) are conducted for seismic evaluation. Also, five different sizes with four different sets of friction coefficients are assumed for base isolators to cover a whole range of base isolation systems with various geometry configurations and fundamental period. The results are investigated in terms of base shear, buildings' drift and top deck acceleration of the superstructure. The results also indicate the profound effect of the stiffness of the adjacent buildings on the value of the impact they impose to the superstructure. Also, in situations of potential pounding, the increment of the fundamental period of the TFPB base isolator could intensify the impact force up to nearly five-fold.

Criterion for judging seismic failure of suspen-domes based on strain energy density

  • Zhang, Ming;Parke, Gerry;Tian, Shixuan;Huang, Yanxia;Zhou, Guangchun
    • Earthquakes and Structures
    • /
    • 제15권2호
    • /
    • pp.123-132
    • /
    • 2018
  • In this paper the strain energy density (SED) model is used to analyze the seismic behavior of suspen-domes and a new criterion is established for judging the seismic failure based on a characteristic point in the SED model. Firstly, a nonlinear time-history response analysis was carried out using the finite-element package ANSYS for typical suspen-domes subjected to different ground motions. The seismic responses including nodal displacements, ratios of yielding members, strain energy density and structural maximum deformation energy were extracted corresponding to the increasing peak ground acceleration (A). Secondly, the SED sum ($I_d$) was calculated which revealed that the $I_d-A$ curve exhibited a relatively large change (called a characteristic point) at a certain value of A with a very small load increment after the structures entered the elastic-plastic state. Thirdly, a SED criterion is proposed to judge the seismic failure load based on the characteristic point. Subsequently, the case study verifies the characteristic point and the proposed SED criterion. Finally, this paper describes the unity and application of the SED criterion. The SED method may open a new way for structural appraisal and the SED criterion might give a unified criterion for predicting the failure loads of various structures subjected to dynamic loads.

발파진동에 대한 인접한 지상 저장탱크의 안정성 평가 (Stability Assessment of an Adjacent Ground Storage Tank by Blast-induced Vibration)

  • 정용훈;이정인;최용근
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.19-26
    • /
    • 2006
  • The test blasts were carried out by detonating some single blastholes at two upper sites of the underground storage cavern for the crude oil. One was performed at the entrance site of the construction tunnel and the other at the middle area of the underground storage cavern. Based on the blast-induced nitration measured by the test blasts, we suggested the propagation equations of blasting vibration that were capable of estimating the peak particle velocity. In addition, in order to assess the stability of the adjacent ground storage tank, we did the frequency analysis and the response spectrum analysis with the particle velocity-time history and the particle acceleration-time history that were measured by the test blast carried out on the entrance site of the construction tunnel. In result, it was predicted that the displacement on the highest part of the tank shell was less than the allowable displacement.