• 제목/요약/키워드: Acceleration duct

검색결과 16건 처리시간 0.02초

전기구동 림 추진기의 덕트 형상 최적화 연구 (A study on optimization of duct shape of electric hubless rim-driven propeller)

  • 편용범;배재현;김형호;이창제
    • 수산해양기술연구
    • /
    • 제59권1호
    • /
    • pp.65-73
    • /
    • 2023
  • This study analyzed the duct characteristics of hubless rim-driven propeller (RDP) used in underwater robots. In the previous study, flow visualization experiments were performed with an advancing ratio of 0.2 to 1. The vortex at the front of the duct increased in strength while maintaining its size as the advancing ratio decreased. Therefore, it is necessary to study the optimization of the duct shape. Conventional propeller thrusters use acceleration/deceleration ducts to increase their efficiency. However, unlike conventional propellers, it is impossible to apply to airfoil acceleration/deceleration ducts due to the RDP structure. In this study, duct wake flow characteristics, thrust force, and efficiency according to the duct shape of RDP were analyzed using numerical analysis techniques. Duct design is limited and six duct shapes were designed. As a result, an optimized duct shape was designed considering duct wake flow characteristics, thrust force, and efficiency. The shape that the outlet width of the RDP was kept constant until the end of the duct showed higher thrust force and efficiency.

Fully nonlinear time-domain simulation of a backward bent duct buoy floating wave energy converter using an acceleration potential method

  • Lee, Kyoung-Rok;Koo, Weoncheol;Kim, Moo-Hyun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제5권4호
    • /
    • pp.513-528
    • /
    • 2013
  • A floating Oscillating Water Column (OWC) wave energy converter, a Backward Bent Duct Buoy (BBDB), was simulated using a state-of-the-art, two-dimensional, fully-nonlinear Numerical Wave Tank (NWT) technique. The hydrodynamic performance of the floating OWC device was evaluated in the time domain. The acceleration potential method, with a full-updated kernel matrix calculation associated with a mode decomposition scheme, was implemented to obtain accurate estimates of the hydrodynamic force and displacement of a freely floating BBDB. The developed NWT was based on the potential theory and the boundary element method with constant panels on the boundaries. The mixed Eulerian-Lagrangian (MEL) approach was employed to capture the nonlinear free surfaces inside the chamber that interacted with a pneumatic pressure, induced by the time-varying airflow velocity at the air duct. A special viscous damping was applied to the chamber free surface to represent the viscous energy loss due to the BBDB's shape and motions. The viscous damping coefficient was properly selected using a comparison of the experimental data. The calculated surface elevation, inside and outside the chamber, with a tuned viscous damping correlated reasonably well with the experimental data for various incident wave conditions. The conservation of the total wave energy in the computational domain was confirmed over the entire range of wave frequencies.

S자형 환형덕트가 원심압축기 성능에 미치는 영향에 관한 연구 (A Study on the Influence of S Shaped Annular Duct on the Centrifugal Compressor Performance)

  • 정주현;전승배;김승우
    • 한국추진공학회지
    • /
    • 제2권2호
    • /
    • pp.64-73
    • /
    • 1998
  • 항공기용 엔진에는 압축기단들 사이에 스트럿을 포함하는 S자형 환형덕트가 존재하기도 한다. 이러한 엔진에서 S자형 덕트를 통과하는 유동은 볼록면과 오목면을 따라 가면서 가속과 감속이 이루어지고, 벽면에서의 경계층 성장으로 인해 유로폐쇄량이 증가한다. 이처럼 S자형 덕트의 영향으로 후방에 존재하는 압축기는 불균일한 축방향 속도분포에 따른 영향을 받게 된다. 따라서, 후방 압축기는 전방에 위치한 S자형 덕트의 영향을 충분히 고려하여 설계하여야 한다. S자형 덕트가 미치는 영향을 고려하여 설계된 원심압축기의 성능을 검증하고, S자형 덕트가 원심압축기 성능에 미치는 영향을 파악해보기 위해 압축기 입구에 S자형 환형덕트를 장착한 경우와 원통형 덕트를 장착한 경우에 대해 각각 성능시험을 수행하였다. 시험결과를 통해 입구에 S자형 덕트가 있는 경우에는 없는 경우보다 압축비 및 효율 등 압축기 성능이 저하되고, 쵸킹유량이 감소함을 알 수 있었다. 이러한 성능저하의 원인을 분석하기 위해 S자형 덕트를 포함하는 임펠러의 유동해석을 수행하였으며, 그 결과 성능저하의 원인은, S자형 덕트와 임펠러의 상호작용으로 설계시 예측했던 것보다 인듀서팁에서 상대마하수가 증가하였고, 영각이 감소하였기 때문임을 확인할 수 있었다.

  • PDF

유동가시화를 통한 다중 수중익 덕트 내 유속조절에 대한 연구 (Study on Flow Velocity Control of a Multiple Hydrofoil Duct via Flow Visualization Techniques)

  • 김지훈;;원보름;;고진환
    • 한국가시화정보학회지
    • /
    • 제14권2호
    • /
    • pp.12-17
    • /
    • 2016
  • In this work, we investigate the flow velocity controllability of a diffuser-type multiple hydrofoil duct by experimental and numerical flow visualization approaches. The flow velocity controllability is analyzed by changing the angle of the hydrofoil near the outlet, which is the diffuser, while the incoming flow velocity is 0.6 m/s in the experiment. When the diffuser angle is changed from 0 to 7.5 degree, the maximum velocity inside the duct is varied from 1.35 m/s to 1.52 m/s. Also, it is shown from the numerical analysis that the maximum velocity is varied from 1.09 m/s to 1.17 m/s in the same condition. Thus, the aspect of the acceleration in the duct due to the increase of the diffuser angle is similar between the both approaches. Therefore, the multiple hydrofoil duct can be used to control the flow speed inside the duct for continuously extracting power close to a rated capacity.

2차 유동 영역에서 꺽임각 변화에 따른 주름진 사각 덕트에서의 열/물질전달 및 유동 특성 (Two dimensional flow and heat/mass transfer characteristics in rectangular wavy duct with corrugation angle)

  • 권현구;황상동;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2267-2272
    • /
    • 2007
  • The present study investigates the two dimensional flow and heat/mass transfer characteristics of wavy duct with various corrugation angles. For the heat/mass transfer coefficients, a naphthalene sublimation technique is used. Numerical analysis and wall pressure measurement show detailed two dimensional flow features. The corrugation angles change from 145$^{\circ}$ to 100$^{\circ}$. The operating Reynolds numbers based on the duct hydraulic diameter vary from 700 to 3,000. The duct aspect ratio maintains 7.3. On the pressure wall, strong flow mixing enhances heat/mass transfer coefficients at the front position. In addition, the rear side of pressure wall, the near of peak, is affected by the acceleration and the shedding of main flow. On the suction wall, however, flow separation and reattachment lead to the valley and the peak of heat/mass transfer coefficient. Also, highly increasing boundary layer at the suction wall affects the decrease of heat/masst transfer. As decreasing corrugation angles, the spanwise average Sherwood number increases and the peak or the valley positions of the local Sherwood number are varied.

  • PDF

쐐기형 요철이 설치된 사각덕트에서의 열/물질전달 및 압력강하 특성 (Heat/Mass Transfer and Pressure Drop in A Square Duct with V-Shaped Ribs)

  • 최청;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1542-1551
    • /
    • 2002
  • The present study investigates the convective heat/mass transfer characteristics and pressure drop inside the rib-roughened cooling passage of gas turbine blades. The internal cooling passage is simulated using a square duct with h- and V-shaped rectangular ribs which have a 60。attack angle. A naphthalene sublimation technique is employed to determine the detailed local heat/mass transfer coefficients using the heat and mass transfer analogy. The ribs disturb the main flow resulting in the recirculation and secondary flows near the ribbed wail. The secondary flow patterns and the local heat transfer in the duct are changed significantly according to the rib orientation. A square duct with ∧ - and V-shaped ribs have two pairs of secondary flow due to the rib arrangement. Therefore, the average heat/mass transfer coefficients and pressure drop of ∧ - and V-shaped ribs are higher than those of the continuous ribs with 90$^{\circ}$ and 60$^{\circ}$attack angles. The ∧-shaped ribs have higher heat/mass transfer coefficients than the V-shaped ribs, and the uniformity of heat/mass transfer coefficient are increased with the discrete ribs due to the flow leakage and acceleration near the surface.

4각 덕트의 입구영역에서 천이 정상유동의 입구길이에 관한 연구 (A Study on Entrance Length of Developing Transitional Steady Flows in a Square Duct)

  • 박길문;유영태;고영하
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.1-10
    • /
    • 1990
  • In the present study, the entrance length, velocity profiles and waveforms of developing transitional steady flows in a square duct are investigated analytically and experimentally. The systems of conservation equations for transitional steady duct flows are solved analytically by linearizing non-linear convective terms and adoption of modified eddy viscosity from empirical correlations. Analytical solutions of velocity profiles for developing transitional steady flow were obtained in the form of infinite series. The experimental study for transitional steady flow in a square duct with $40mm{\times}40mm{\times}4000mm$($width{\times}height{\times}length$) was carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with data acquisition and processing system. The entrance length of developing transitional steady flows in a square duct was $L_e{\fallingdotseq}0.02{\cdot}Re,st{\cdot}D_h$, and the overshoot was occured at about 30 times of hydraulic diameter because of the effect of external velocity of boundary layer and instantaneous acceleration.

  • PDF

수직구조물 후방의 와류현상이 구조물에 설치된 벤투리관의 유체가속 효과에 미치는 영향에 관한 해석 연구 (Effect of Rear-Vortex of a Convergent-Divergent Duct on the Flow Acceleration Installed in a Vertical Structure)

  • 정광섭;김철호;조현성
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.94-100
    • /
    • 2013
  • A convergent-divergent nozzle or venturi nozzle has been used to accelerate the wind speed at its throat. The wind speed at the throat is inversely proportional to its area according to the continuity equation. In this numerical study, an airflow phenomena in the venturi system placed at a vertical structure was investigated to understand the vortex effect occurred at the rear-side of the vertical structure on the air speed increment at the throat of the venturi system. For this study, a venturi system sized by $20(m){\times}20(m){\times}6(m)$ was modelled and the area ratio(AR) of the model venturi was 2.86. To see the vortex effect on the air flow acceleration in the venturi throat, two different boundary conditions was defined From the study, it was found that the pressure coefficient(CP) of the venturi system with the vortex formed at the exit of the venturi was about 2.5times of the CP of the venturi system without the vortex effect. The velocity increment rate of the venturi system with the vortex was 61% but 9.5% only at the venturi system without the vortex. Conclusively, it can be said that the venturi system installed in a vertical structure has very positive effect on the flow acceleration at its throat due to the vortex formed at the rear-side of the vertical structure.

스테레오 PIV를 이용한 워터젯 흡입덕트 내부의 난류유동측정 (Stereoscopic PIV Measurement on Turbulent Flows in a Waterjet Intake Duct)

  • 권성훈;윤상열;전호환;김경천
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.612-618
    • /
    • 2004
  • Stereoscopic PIV measurements were made in the wind tunnel with the actual size waterjet model. The main wind tunnel provides the vehicle velocity while the secondary wind tunnel adjusts the jet issuing velocity. Experiments were performed at the range of jet to vehicle velocity ratio (JVR), 3.75 to 8.0 and the Reynolds number of 220,000 based on the jet velocity and the hydraulic diameter of the waterjet intake duct. Wall pressure distributions were measured for various JVRs. Three dimensional velocity fields were obtained at the inlet and outlet of the intake duct. It is found that severe acceleration is occurred at the lip region while deceleration is noticeable at the ramp side. The detailed three dimensional velocity fields can be used as the accurate velocity input for the CFD simulation. It is interesting to note that there are many different types of vortices in the instantaneous velocity field. It can be considered that those vortices are generated by the corner of rectangular section of the intake and Gortler vortices due to the curved wall. However, typical secondary flow with a pair of counter rotating vortex pair is clearly seen in the ensemble averaged velocity field.

덕트내 요철의 단락위치 변화에 따른 열/물질전달 및 압력강하 특성 - 정렬 단락배열 요철 - (Heat/Mass Transfer and Friction Characteristic in a Square Duct with Various Discrete Ribs -In-Lined Gap Arrangement Ribs-)

  • 이세영;최청;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1640-1649
    • /
    • 2001
  • The present study investigates the effects of various rib arrangements on heat/mass transfer in the cooling passage of gas turbine blades. A complex flow structure occurs in the cooling passage with rib turbulators which promote heat transfer on the wall. It is important to increase not only the heat transfer rates but also the uniformity of heat transfer in the cooling passage. A numerical computation is performed using a commercial code to calculate the flow structures and experiments are conducted to measure heat/mass transfer coefficients using a naphthalene sublimation technique. A square channel (50 mm $\times$ 50 mm) with rectangular ribs (4 mm $\times$ 5 mm) is used fur the stationary duct test. The experiments focus on the effects of rib arrangements and gap positions in the discrete ribs on the heat/mass transfer on the duct wall. The rib angle of attack is 60°and the rib-to-rib pitch is 32 mm, that is 8 times of the rib height. With the inclined rib angle of attack (60°), the parallel rib arrangements make a pair of counter rotating secondary flows in the cross section, but the cross rib arrangements make a single large secondary flow including a small secondary vortex. These secondary flow patterns affect significantly the heat/mass transfer on the ribbed wall. The heat/mass transfer in the parallel arrangements is 1.5 ∼2 times higher than that in the cross arrangements. However, the shifted rib arrangements change little the heat/mass transfer from the inline rib arrangements. The gap position in the discrete rib affects significantly the heat/mass transfer because a strong flow acceleration occurs locally through the gap.