• 제목/요약/키워드: Accelerating degradation

검색결과 74건 처리시간 0.022초

전자제품용 컴프레서의 가속열화시험에 관한 연구 (An Accelerated Degradation Test of a Electronics Appliance Compressor)

  • 이후진;윤원영
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권1호
    • /
    • pp.25-38
    • /
    • 2010
  • In this paper, an accelerated degradation test procedure for an electronic appliance compressor is proposed. We investigate the amount of wear of the compressor and consider several factors as accelerating factors. Finally we select the operating pressure as a main accelerating factor. The test condition of accelerated degradation test is determined. The modified accelerating test reduces the test time in design phase by using the suggested accelerating factor.

철도차량 견인전동기의 가속열화수명평가 기술현황 (A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock)

  • 왕종배;김기준;최영찬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

가속 열화 모형을 이용한 엘리베이터 와이어 수명 예측 (Estimation of Elevator Wire Life Using Accelerated Degradation Model)

  • 김상부;김승호
    • 품질경영학회지
    • /
    • 제43권3호
    • /
    • pp.409-420
    • /
    • 2015
  • Purpose: This study is to estimate the life of elevator wire rope by using the accelerated degradation test with two accelerating variables of applied load and corrosion. Methods: Linear regression method is used to find the pseudo life of elevator wire rope at each combination of accelerating variables and the median life of elevator wire rope at use condition is estimated under the assumption that the life of elevator wire rope follows lognormal distribution. Results: The particular case study demonstrated that the results of the elevator wire life estimation by using the proposed method can provide the better solutions than existing methods. Conclusion: It can be economical to use accelerated degradation model for estimating the life of elevator wire rope.

전기철도용 견인전동기의 복합가속열화 상태진단에 관한 연구 (A Study on the Complex Accelerating Degradation and Condition Diagnosis of Traction Motor for Electric Railway)

  • 왕종배
    • 한국전기전자재료학회논문지
    • /
    • 제15권1호
    • /
    • pp.93-101
    • /
    • 2002
  • In this study, the stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the C-Class(200$\^{C}$ ) insulation system of traction motors. The complex accelerative degradation was periodically performed during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, the condition diagnosis test such as insulation resistance '||'&'||' polarization index, capacitance '||'&'||' dielectric loss and partial discharge properties were investigated in the temperature range of 20 ∼ 160$\^{C}$. Relationship among condition diagnosis tests was analyzed to find a dominative degradation factor and an insulation state at end-life point.

견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가 (Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis)

  • 왕종배;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF

분위기 온도와 플라즈마 방전에 의한 AC-PDP의 형광막 열화 특성 (The Degradation Characteristics of Phosphor Layers by Environmental Temperature and Plasma Discharge in AC-PDPs)

  • 김현;장상훈;태흥식;최경철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.443-448
    • /
    • 2002
  • The degradation characteristics of R, G, B phosphor layers in AC-PDP, which is due to the discharge of plasma, are still unknown. For the successful commercialization of AC-PDP, the degradation of phosphor layers, caused by the plasma discharge must be investigated and improved. In this paper, the degradation properties of phosphor layers in AC-$PDP_S$ are investigated. It takes long time to investigate the degradation in real condition, so that the device for accelerating the degradation is devised. To prove the performance of the device, the visible emission characteristics of phosphor layers and discharge with the environmental temperature are examined. As a result, it is shown that the phosphor layers are easily degraded when the discharge is sustained under high environmental temperature condition. After accelerating the degradation of blue Phosphor layer((Ba,Eu)Mg$AI_10$$O_17$) for 48 hours, its luminance decreases about 38 % and the corresponding color purity deteriorates severely.

견인전동기의 고강예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 고전압 인가에 따른 유전손실 및 부분방전 특성 연구 (Condition Diagnosis by the Complex Accelerating Degradation for Fault Prediction & Estimation of Reliability on the Traction Motor - Dielectric loss and PD Properties according to High Voltage)

  • 왕종배;백종현;변윤섭;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1371-1373
    • /
    • 2000
  • In this paper, the complex accelerating degradation of traction motor driven with VVVF controlled inverter were performed on the form coil samples with the 200 Class insulation system. in order to evaluate the reliability and the long-term life. After aging, the dielectric and PD properties were investigated on the 10 cycles aging sample in the range of $20{\sim}160[^{\circ}C]$ and AC $250{\sim}2250[V]$ to diagnosis the condition of end-life and find the dominative factors of degradation.

  • PDF

Degradation of Coatings under Atmospheric Tropical Conditions

  • To, Thi Xuan Hang;Pham, Gia Vu;Vu, Ke Oanh;Trinh, Anh Truc;Kodama, Toshiaki;Tanabe, Hiroyuki;Taki, Tohru;Nagai, Masanori
    • Corrosion Science and Technology
    • /
    • 제2권5호
    • /
    • pp.207-211
    • /
    • 2003
  • The weather resistance of five coatings systems based on alkyd, chlorinated rubber, epoxy, polyurethane and fluoropolymer were studied by natural exposure test and accelerated test. The coatings were exposed at Hanoi station with urban industry atmosphere and at Baichay station with marine atmosphere. The degradation of coatings was evaluated by gloss measurement and surface analysis by scanning electronic microscopy. The results obtained show that among coatings tested the gloss of polyurethane and fluoropolymer coatings remained highly and those of alkyd, chlorinated rubber and epoxy coatings were very low after two years of atmospheric exposure. Under accelerating conditions the gloss of fluoropolymer coatings remained highly after 80 cycles of testing. By comparison with accelerating test in UV-condensation chamber the conditions at atmospheric stations are more aggressive.

산업용 청소기 모터의 가속수명시험 (Accelerated Life Test of Industrial Cleaner Motor)

  • 엄학용;이기천;장무성;박종원;이용범
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권3호
    • /
    • pp.193-200
    • /
    • 2018
  • Purpose: In this study, the life of the motor is investigated by performing the accelerated life test with the brush wear of the industrial cleaner motor as the main failure mode. Methods: The accelerating stress factor of the accelerated life test is a voltage, which can increase the number of revolutions of the motor to accelerate the brush wear due to the friction between the brush and the commutator. Also, the accelerating stress level was determined after determining the maximum allowable level of the voltage through the preliminary test. Results: The motor failure time at each accelerating stress level was predicted by regression analysis with brush wear length as performance degradation data. The main failure mode, which is brush wear, of the motor was reproduced by this test. The shape parameter of the Weibull distribution was confirmed to be the same statistically at all accelerating stress levels by the likelihood ratio test. Conclusion: The life of the motor was investigated by performing the accelerated life test with the brush wear of the industrial cleaner motor as the main failure mode. Through the accelerating test method of the cleaner motor, various life expectancy and life expectancy of the acceleration factor are predicted.

제한된 산소 존재중의 Ascorbin 산의 분해에 대하여 (Degradation of Ascorbic acid in Limited Dissolved Oxygen Environment)

  • 이숙희
    • Journal of Nutrition and Health
    • /
    • 제9권4호
    • /
    • pp.54-58
    • /
    • 1976
  • Vitamin C의 변화는 식품의 가치를 판단하는데 중요한 인자가 된다. 이의 변화는 산소의 존재하에서 일차반응 속도로 분해된다고 알려져 있다. 그러나 제한된 량의 산소 속에서는 이차반응 내지 일차반응으로 설명되기도 한다. 이에 제한된 산소속에서 철, 구리 이온의 존재하에서 관찰한 바 용존산소와는 크게 관계없이 일차 반응속도로 분해되었고 이때 빛의 조사는 촉진적인 인자였었다.

  • PDF