• Title/Summary/Keyword: Accelerated Degradation

Search Result 511, Processing Time 0.026 seconds

Reliability Analysis of MLCC Degradation Data based on Eyring Model (아이링 모델에 기초한 MLCC 열화데이터의 신뢰성 해석)

  • 김종철;김광섭;차종범
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.239-246
    • /
    • 2004
  • Accelerated degradation test (ADT) can be a useful tool for assessing the reliability when few or even no failure are expected in an accelerated life test. In this paper, MLCC (Multilayer Ceramic Capacitors), a sort of passive components which have large capacitance(X7R -55$^{\circ}C$~1$25^{\circ}C$) have been tested, and least-square analyses are used to illustrate our approach in which amount of degradation of a DUT following log-normal distribution. We assumed a simple and useful linear model to describe the amount of degradation over time subjected to different voltage levels applied. Tests for linearity of the performance-time relationship, and provide tests for how well the assumptions hold. Also, by using Eyring Model, MLCC's mean life time is assessed.

  • PDF

Durability of MEA Using sPEEK Membrane Reinforced with Poly Imide in PEMFC (고분자전해질연료전지에서 폴리이미드 강화 sPEEK막 MEA의 내구성)

  • Lee, Hye-Ri;Na, Il-Chai;Oh, Sung-Jun;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.296-301
    • /
    • 2017
  • Recently, there are many efforts focused on development of more economical non-fluorinated membranes for PEMFCs (Proton Exchange Membrane Fuel Cells). In this study, sulfonated poly (ether ether ketone) (sPEEK) membrane reinforced with poly imide was made to enhance of membrane durability. In order to test durability of single (un-reinforced) membrane and reinforced membrane MEA (Membrane and Electrode Assembly), degradation accelerated stress test was used. Before and after degradation, I-V polarization curve, hydrogen crossover current, electrochemical surface area, membrane resistance and charge transfer resistance were measured. As a result of experiments, hydrogen crossover current of reinforced MEA was lower than that of single MEA, therefor durability of reinforced MEA was higher than that of single MEA. There was not especially short phenomena in reinforced MEA after degradation accelerated stress test.

A STUDY ON THE ACCELERATED LIFE TESTS OF IMAGE INTENSIFIER ASSEMBLY(KIT-7) (야간투시경용 영상증폭관(KIT-7)의 가속수명시험에 관한 연구)

  • Kim, Sung-Min;Park, Jung-Won;Ham, Jung-Keol;Kim, Kwang-Youn
    • Journal of Applied Reliability
    • /
    • v.7 no.3
    • /
    • pp.127-136
    • /
    • 2007
  • The accelerated life tests(ALTs) and degradation characteristics of image intensifier assembly(KIT-7) under low illuminance and high temperature were investigated. The accelerated life tests were carried out at $5{\times}10^5\;fc-40^{\circ}C,\;10{\times}10^5\;fc-40^{\circ}C,\;5{\times}10^5\;fc-50^{\circ}C,\;10{\times}10^5\;fc-50^{\circ}C$ and relationship related to illuminance and temperature was used as an accelerated life test model. An ALTA program[6] was used to calculate an acceleration factor and the test of life distribution fit, and estimate three parameters of an life test model. To sum up, MTTF 10,000 h at $5{\times}10^{-5}\;fc-40^{\circ}C$ of image intensifier assembly was certificated.

  • PDF

Research Results and Trends Analysis on Accelerated Testing for Ensuring High Reliability (고 신뢰성 확보를 위한 가속시험의 연구동향 분석)

  • Kim, Jong-Gurl;Song, Jung-Moo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.419-432
    • /
    • 2011
  • 제품의 신뢰성에 대한 소비자의 인식이 높아짐에 따라 기업에서는 높은 품질과 신뢰성 있는 제품을 만들기 위해 많은 노력을 하고 있다. 신뢰성은 기기, 부품, 재료 등 시스템이 규정된 조건하에서, 의도하는 기간 동안 규정된 기능을 고장 없이 수행할 수 있는 성질로 규정된다. 높은 신뢰성의 확보를 위한 제품의 신뢰성 시험은 많은 시간과 비용이 소모되기 때문에 현대의 빠른 시장 흐름에 따라가지 못한다. 특히, 최근 기술발전 속도가 빨라지고 제품 수명주기(Life Cycle)와 개발 기간이 짧아지고 있는 추세에 있으므로 이에 대응할 수 있는 신속한 시험방법의 실시가 반드시 필요한 시점이다. 위와 같은 신뢰성을 갖는 제품의 시험의 한계를 극복하고 시험시간을 단축하기 위한 여러 가지 방법이 연구되어 왔고, 그 중 가속 시험(Accelerated Test)에 대한 필요성과 요구가 계속 증가하고 있는 추세다. 본 연구에서는 단순부품과 재료의 신뢰도 정보를 신속하게 얻는데 매우 유용한 신뢰성 시험방법 중에 하나인 가속시험의 연구동향과 적용 현황을 분석하고 이의 효과적인 적용과 활용방안을 모색 하고자 한다.

  • PDF

Multiple accelerated degradation test and failure analysis for $Ni-BaTiO_3$ MLCCs ($Ni-BaTiO_3$ MLCCs에 대한 복합 가속 열화 시험 및 고장 분석)

  • Kim, Jung-Woo;Kim, Jin-Seong;Lee, Hee-Soo;Kang, Do-Won;Kim, Jeong-Wook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.2
    • /
    • pp.102-105
    • /
    • 2009
  • The accelerated life time test of the MLCCs with different $BaTiO_3$ particle sizes were conducted at $150^{\circ}C$, 75 V condition and the effect of $BaTiO_3$ particle size on the breakdown voltage and degradation characteristics of MLCCs was investigated. The MLCCs were prepared by using the $BaTiO_3$ particles having the size of $0.525{\mu}m$, $0.555{\mu}m$, $0.580{\mu}m$ and Ni-electrode, respectively. The MLCCs which have the particle size of $0.525{\mu}m$, $0.555{\mu}m$, and $0.580{\mu}m$, respectively were confirmed to meet the standard requirements of X5R(change capacitance within ${\pm}15%$ at $-55{\sim}85^{\circ}C$) by TCC(Temperature Coefficient of Capacitance). The effect of the $BaTiO_3$ particle size on the insulation resistance behavior of MLCCs was confirmed by BDV(Breakdown Voltage) measurements and the cause and degree of degradation of MLCCs were characterized by XPS analysis after the accelerated life test. The MLCCs with $0.525{\mu}m-BaTiO_3$ showed better insulation resistance and BDV characteristics compare to other MLCCs and XPS analysis revealed that the MLCCs degradation is caused by the NiO peak and $BaTiO_3$ peak decrease.

Studies on the Stability of Trimebutine maleate in Aqueous Solution (수용액 중 Trimebutine maleate의 안정성)

  • Park, Jong-Hyen;Rhee, Gye-Ju
    • YAKHAK HOEJI
    • /
    • v.34 no.6
    • /
    • pp.415-421
    • /
    • 1990
  • The effects of temperature, pH, light and concentration on the degradation of trimebutine maleate in aqueous solution were investigated on the basis of accelerated stability analysis, and the stabilization of the solution was attempted by addition of several additives. The decomposition of trimebutine maleate in solution followed first-order reaction the was not only accelerated by temperature elevation but also the lower the concentratin the more speeded up the reaction. The decomposition mechanism of trimebtine could be confirmed by hydrolysis of ester bond in the structure. It was assumed trimebutine maleate is so photosensitive that the solution of the drug underwent accelerated decomposition under UV rays. What is more, the degradation of trimebutine solution was supposed to catalyzed by specific acid-base catalysis considered the pH dependence for the hydrolysis of ester, and the solution was most stable over the range of pH 2-2.8 in solution. The additives, citric acid, asparitc acid and glutamic acid, inhibited considerably the decomposition of the drug solution, and these additives might be used as stabilizers in trimebutine maleate solution.

  • PDF

Evaluation of Nuclear Plant Cable Aging Through Condition Monitoring

  • Kim, Jong-Seog;Lee, Dong-Ju
    • Nuclear Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.475-484
    • /
    • 2004
  • Extending the lifetime of a nuclear power plant [(hereafter referred to simply as NPP)] is one of the most important concerns in the global nuclear industry. Cables are one of the long-life items that have not been considered for replacement during the design life of a NPP. To extend the cable life beyond the design life, it is first necessary to prove that the design life is too conservative compared with actual aging. Condition monitoring is useful means of evaluating the aging condition of cable. In order to simulate natural aging in a nuclear power plant. a study on accelerated aging must first be conducted. In this paper, evaluations of mechanical aging degradation for a neoprene cable jacket were performed after accelerated aging under tcontinuous and intermittent heating conditions. Contrary to general expectations, intermittent heating to the neoprene cable jacket showed low aging degradation, 50% break-elongation, and 60% indenter modulus, compared with continuous heating. With a plant maintenance period of 1 month after every 12 or 18 months operation, we can easily deduce that the life time of the cable jacket of neoprene can be extended much longer than extimated through the general EQ test. which adopts continuous accelerated aging for determining cable life. Therefore, a systematic approach that considers the actual environment conditions of the nuclear power plant is required for determining cable life.

Solubility and Physicochemical Stability of Caroverine Hydrochloride in Aqueous Solution (수용액중 염산카로베린의 용해성 및 안정성)

  • Gwak, Hye-Sun;Lee, Dong-Soo;Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.2
    • /
    • pp.121-126
    • /
    • 1998
  • The solubility and physicochemical stability of caroverine hydrochloride (CRV), an antispasmodic, in buffered aqueous solutions were studied using a reverse phase high performance liquid chromatography. The solubilty of the drug at pH 2.76-5.40 was similar at the range 31.9-36.2 mg/ml $(34^{circ}C)$, but, at the pH higher than 6.0, markedly decreased. The use of polyethylene glycol 400 as a cosolvent did not increase the solubility at any compositions examined. Moreover. increasing molar concentration of aqueous phosphate buffer from 0 to 0.5 M remarkably decreased the solubility. The degradation of CRY followed the apparent first-order kinetics. The degradation was accelerated with decreasing pH and increasing storage temperature. The half-lives for the degradation of CRY (1.0 mg/ml) at pH 1.28. 4.01 and 5.93 $(45^{\circ}C)$ were 2.8, 31.4 and 124 hr. respectively. The pHs of incubated solutions were to some extent lowered perhaps due to the formation of acidic degradation products. The addition of disodium edetate (0.01%) to the CRY solution (pH 4.95) retarded 2.5 times the degradation rate at $45^{\circ}C$, but the use of sodium bisulfite (0.1%) accelerated 2.9 times the rate. The activation energy for the CRY solution (20 mg/ml. pH 5.4) containing 0.01% EDTA was calculated to be 5.98 kcal/mole. When the solution was stored under nitrogen displacement in ampoule, there was no significant degradation even after 3 months at $40^{\circ}C$, indicating that protection from oxidation by air (oxygen) is essential for the complete stabilization of CRY solution.

  • PDF

Property of Poly(amic acid) Precursor Solution (Poly(amic acid) 전구체 용액의 성질)

  • Ahn, Young Moo
    • Textile Coloration and Finishing
    • /
    • v.8 no.2
    • /
    • pp.43-48
    • /
    • 1996
  • Condensation type aromatic polyimides were synthesized in DMF solvent by two step low temperature solution polymerization. By employing monomers as p-phenylene 3diamine and 3 kinds of dianhydrides such as pyromellitic dianhydride, 3,3',4,4'-benzophenone tetracarboxylic dianhydride and trimellitic anhydride chloride, poly(amic acid) precursors were sythesized. These reactions were exothermic and very fast. When synthesized poly(amic acid)s were dissolved in DMF solvent and stood long time, the polymers were hydrolyzed and their degradation reactions were accelerated as the solution concentrations were dilute. Also, when water is added there-to the degradation rates were accelerated 8faster. In addition, in a very dilute solution state, the reduction viscosity is greatly increased to show properties of conventional polyelectrolytes. This also showed properties sensitive to the concentration change as carboxyl groups per unit segment are increased.

  • PDF

Experimental Study on Ultra-Violet Resistance of FRP composites used in Strengthening RC members (FRP 복합체의 자외선 저항성에 관한 실험적 연구)

  • Song, Tae-Hyeob;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.333-336
    • /
    • 2006
  • In general, polymer materials undergo degradation when exposed to ultraviolet radiation, which can cause dissociation of chemical bonds. FRP composites which are used in strengthening existing structure are usually adhered on the concrete surface, its mechanical properties as well as appearance such as color, surface conditions are affected by sunlight and expecially ultraviolet light. In this study, variations of tensile strength after exposure for certain period of time through accelerated exposure by Xe arc methods specified in KS F 2274 are measured in order to examine strength degradation characteristics of FRP composite. As a result of ultraviolet light test for FRP composite after accelerated exposure for 0, 500, 1000, 1500 hour, discoloration of FRP composite occurs according to the passage of time. But, few strength degradations of FRP composite are observed due to exposure of ultraviolet ray with an small variation of tensile strength.

  • PDF