• Title/Summary/Keyword: Ac-225

Search Result 40, Processing Time 0.026 seconds

Complementary Calculation of Current Carrying Capacity for Bare Overhead Conductors (가공선용 나전선의 허용전류 산정 보완)

  • Son, Hong-Gwan;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.225-231
    • /
    • 2002
  • Many standards have Published for calculating of current carrying capacity for bare overhead conductors. Although these standards use the same basic heat balance concept, they use different approaches to calculate current carrying capacity, This paper looks at the four approaches used to calculate individual heat balance terms, at the overall impact of these terms on the current carrying capacity And this paper is proposed to the selection of proper standard and AC resistance within a country conditions for calculating the current carrying capacity of bare overhead conductors. So current carrying capacities are Proposed to some of conductors.

Modelling development of the Electromagnetic Transient Analysis of the JeJu Power System (제주 전력계통의 전자기과도해석 모델링 개발)

  • Choi, Joon-Ho;Nam, Hae-Kon;Nam, Soon-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.223-225
    • /
    • 2008
  • 본 논문은 제주 계통의 전자기적 과도 해석을 위해 상세한 전자기 과도해석 모델링 개발 및 절차에 관한 내용을 다루고 있다. 제주 전력계통의 모델링은 크게 제주도내의 화력발전 모델링과 육지와 연계된 해남-제주간 Bi-pole HVDC 모델링으로 구분하여 개발하였고 이를 통합하였다. 모델링의 정확성 확보를 위해 기존에 개발된 PSS/E 모델링과 비교하여 개발하였다. 사례연구로는 HVDC상세 모델과 제주 AC 전력계통을 통합한 과도해석 모델을 사용하여 부하 급변등, 사고해석 등을 사례연구를 수행하였다.

  • PDF

BSCCO 초전도선재의 twisting 공정연구

  • Im, Jun-Hyeong;Ji, Bong-Gi;Park, Hyeong-Sang;Ju, Jin-Ho;Jang, Mi-Hye;Go, Tae-Guk;Ha, Hong-Su;O, Sang-Su
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.221-225
    • /
    • 2000
  • The effect of twisting on the microstructural evolution and critical current of BSCCO superconductor tape has been evaluated. Twisting pitches of the tapes are in the range of 8-70 mm and uniformly deformed. The critical current of twisted tape was dependent on the twist pitch. Specifically, it was observed that the critical current decreased with decreasing twist pitch, and only 50% of critical current was retained when the tape was twisted to a pitch of 8 mm. This reduction of the critical current may be related to the interface irregularity, smaller grain size, worse texture and the presence of cracks due to the induced strain during the twisting processing.

  • PDF

The Effect of Interpenetrating Polymer Network upon Tracking Resistance of Epoxy Composite Materials (에폭시 복합재료의 내트래킹성에 미치는 상호침입망목의 효과)

  • 김탁용;이덕진;손인환;김명호;김경환;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.225-229
    • /
    • 1996
  • In this study, in order to develop outdoor insulating materials, SIN(simultaneous interpenetrating polymer network) was introduced to Epoxy resin and the environment resistance was investigated. The single network structure specimen(E series) formed of Epoxy resin alone and simultaneous interpenetrating polymer network specimen (EM series) in which epoxy resin was taken as the first network and methyl methacrylate resin as the second network were manufactured. Ten kinds of specimens were manufacture by filler (SiO$_2$) content. SEM were utilized in order to confirm their network structure changes, and AC voltage dielectric strength was measured. Also, UV-test and tracking test were carried out investigate the environment resistance characteristic. Therefore the variations of network structure were happened as a result of SEM test, and it was confirmed that simultaneous interpenetrating polymer network specimens were more excellent than single network structure specimens.

  • PDF

Partial Discharge Properties of High Voltage Motor Stator Insulation using Partial Discharge Analyzer (PDA를 이용한 고압전동기 고정자 권선에서 부분방전 특성)

  • Kim, Hee-Dong;Lee, Sang-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.225-228
    • /
    • 2001
  • Partial discharge(PD) testing for different capacitive couplers was performed on a 6.6kV, 448kW pulverizer motor. The motor has been in service for twenty years. PD tests were measured using digital partial discharge detector(DPDD) and partial discharge analyzer(PDA), respectively. PDA is used to in the motor stator insulation, which three 80pF or three 500pF epoxy-mica couplers were installed, one per phase. The 500pF couplers did detect more normalized quantity number(NQN) than the 80pF couplers. DPDD and PDA showed that PD and NQN magnitudes increased with increase of ac voltage. Internal discharge was discovered in the motor stator insulation. DPDD and PDA test results are in accordance with the pattern and magnitude of PD.

  • PDF

Experimental Study on the Active Control of a Three-story Building using $\textrm{H}_2$method ($\textrm{H}_2$제어 기법을 적용한 3층 건물의 능동제어 실험)

  • Joo, Soek-Jun;Min, Kyung-Won;Lee, Sung-Kyung;Kim, Sung-Chon;Hong, Sung-Mok
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.225-232
    • /
    • 1999
  • For the study of the seismic-response control, it is necessary to use an experimental system with an earthquake simulator and control devices employing a hydraulic actuator system. However, such system is too expensive to prepare at the university laboratory. In this research, an economical experimental system is developed which has a small-sized earthquake simulator and an AMD using AC servo motors. An accurate mathematical model of the three-degree-of-freedom tests structure with an AMD is developed from the measurement of the input/output relationships of the structure. This paper demonstrates experimentally the efficacy of the frequency domain optimal control algorithm H$_2$in reducing the response of seismically excited building to verify the performance of the experimental system.

  • PDF

Electrical Characteristics of the Interfacial Layer between XLPE/EPDM Laminates on the Heat Treatment (열처리 조건에 따른 XLPE / EPDM 계면의 전기적 특성)

  • 최원창;이제정;김석기;조대식;한상옥;박강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.225-228
    • /
    • 1997
  • The main fault in this interface is that power cable insulating materials are mainly composed of a double layered structure, XLPE/FPDM laminates in cable joint. In this parer, we instituted the interface of XLPE/EPDM laminates and then investigated the breakdown and conduction characteristics as a function of heat treatment time. The results showed that conduction current was influenced by volatile crosslinking by-products which remained inside the insulating material during the production of XLPE and EPDM, especially during heat treatment process. And conduction current of XLPE/Oil 12500cSt/EPDM was more stable than XLPE/Grease/EPDM from the long heat treatment time. AC breakdown strength of silicone oil itself from the heat treatment was changed during the 4∼12 hour heat treatment time.

  • PDF

Characterization of a salicylate-degrading strain of pseudomonas putida (Salicylate를 생분해하는 pseudomonas putida의 특성)

  • 홍순우;하영칠;이계준;배경숙
    • Korean Journal of Microbiology
    • /
    • v.24 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • Eight strains of the bacteria capable of growing on salicylate as the sole carbon source were isolated form soil and river water. Three of these isolates were identified as Acinetobacter calcoaceticus (AcBl), Pseuomonas putida biotype B (PpB2), and P. putida biotype A (PpB3). Effects of temperature, pH and C source concentration on biodegradation of salicylate by PpB3 were wxamined. The optimum conditions were as follows; $30^{\circ}C$ for temperature, 7.0 for pH, and 10mM for C source concentration. Ultraviolet scanning spectrum of the salicylate was measured. The spectrum has two peaks at 225nm and 292nm. The spectra of the culture filtrates indicate that ring degradation of salicylate is accomplished.

  • PDF

Development of simulation on parallel operation of the On-Board Charger (차량용 OBC 병렬운전 시뮬레이션 개발)

  • Zhu, Helin;Mok, HyungSoo;Choi, Sungho;Park, SungUk;Sung, KiHak
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.225-226
    • /
    • 2018
  • 전기자동차 배터리팩을 충전하기 위한 장치인 차량용 OBC(On-Board Charger)는 AC/DC 컨버터 기능을 담당하는 PFC(Power Factor Correction)와 DC/DC 전력변환 및 전기적 절연을 담당하는 Phase-Shifted Full Bridge Converter를 포함 한다. 현재 시중에 3.3kW급 OBC를 기준으로 규격화되어 생산되고 있지만 전기자동차의 배터리 용량이 날로 증가하고 전기자동차 보급, 사용률이 증가함에 따라 완속충전에 대한 요구가 높아지고 있다. 여기에 전력 인프라 시설 개선과 더불어 6.6kW급 완속충전이 보편화될 수 있게 된다. 차량용 OBC 공급업체에 있어서는 기존의 3.3kW급과 6.6kW급 OBC의 개발 중 어느 쪽에 중심을 둘지 고민에 대한 대안으로 기존의 3.3kW급을 모듈화하여 병렬운전하는 방법으로 6.6kW급 OBC 시장수요에 대응 할 수 있다. 본 논문에서는 3.3kW급 OBC 및 2병렬운전에 관한 시뮬레이션을 개발하고 분석하였다.

  • PDF