• Title/Summary/Keyword: Ac/ac conversion

Search Result 360, Processing Time 0.032 seconds

contactless power conversion system using the Boost converter (승압형 컨버터를 활용한 비접촉식 전력변환 시스템)

  • Lee S. J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.214-217
    • /
    • 2003
  • The connectorless power supply system on that multi-contact causes confidence when the wiring reconstructed in the rear. As you see above, contact points between sets and indoor space cause inferior function of audio frequency so it needs to be eliminated. This paper explains the structure of connectorless power supply to supply the system with power crossing the air gap in the part of inductively in the connectorless power supply of both magnetic and electrical model. To get maximum output of electrical load, compensating capacitor compensates to show inter-inductance, lequeage-inductance reducing the track-inductance and access the conditions for resonance. At that time it accesses the maximum electric power. The small change of the value of compensating capacitor causes the changes of maximum electric power. Here the power electronics technology is used not only in the industrial machinery but also in the home appliances so the switching power supply is used to actualize the miniaturization, lightweight, and high efficiency. Generally the condenser input methods are widely used in the rectification circuit of switching power supply, but condenser input method generate great quantity of high frequency components because with this method the current flows in the power input filtering condenser only around value of peak of ac input voltage. To solve these problems, installation of power factor improve circuit on the front of filtering capacitence was considered. Several methods were suggested regarding, but the active filter method which makes smalliging and highly power factor possible are the produce main stream. IC for power factor improvement can be utilized by CMOS process proposing low power consumption. When the high power factor is considered seriously in the power factor improvement circuit, active filter method is selected. In the active filter method, the boost converter is used. Regarding this ·the boost converter is needed.

  • PDF

Boost $1\Psi$ converter of high efficiency by partial resonant switching using lossless snubber (무손실 스너버를 이용한 부분공진 스위칭에 의한 고효율 승압형 단상 컨버터)

  • 서기영;곽동걸;전중함;이현우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.315-322
    • /
    • 1998
  • Power conversion system must increase switching frequency in order to achieve small size, light weight and low noise. However, the switches of converter are subject to high switching power losses and switching stresses. As a result, the power system has a lower efficiency. In this paper, the authors propose an AC-DC boost converter of high efficiency by partial resonant switching mode. The switching devices in the proposed circuit are operated with soft switching and the control technique of those is simplified for switch to drive in constant duty cycle. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. Besides, by regenerating energy, that is charged in a loss less snubber condenser of a snubber adopted to a common circuit, toward an input source part, this circuit can get increased efficiency. as merit. The result is that the switching loss is very low, the efficiency and power factor of system is high. The proposed converter is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Harmonic Analysis for Traction Power Supply System Using Four-Port Network Model (6단자망 회로모델을 이용한 전기철도 급전시스템의 고조파 해석)

  • Chang, Sang-Hun;O, Gwang-Hye;Kim, Ju-Rak;Kim, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.255-261
    • /
    • 2002
  • Recently, traction motors in trains are supplied with single phase a.c. power. After this power is converted to d.c. power, it is inverted to three phase power to operate traction motors. As going through the process of the conversion, harmonic current is generated in train. The method of conventional analysis on harmonics, studied by RTRI, is modeled with equivalent circuit of ac AT-fed electric railroad system using by the distributed constant circuit. However, this circuit as two-port network model has some difference in comparison with real system. The reason why the conventional method is different from the real system is that the conventional method dose not include three conductor groups, that is catenary, rail, and feeder, and admittance between the conductors for line capacitance. Therefore, this method has a little error. This paper proposes new method to more effectively estimate Harmonic current. In this method, numerous components in electric railway are categorized and each component is defined as a four- port network model. The equivalent circuit for the entire power supply system is also described into a four-port network model with connections of these components. In order to evaluate the efficiency and the accuracy of a proposed method, it is compared with values measured in Kyung-Bu high speed line and ones calculated by the conventional method.

Dynamic Magnetostriction Characteristics of an Fe-Based Nanocrystalline FeCuNbSiB Alloy

  • Chen, Lei;Li, Ping;Wen, Yumei
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.211-215
    • /
    • 2011
  • The dynamic magnetostriction characteristics of an Fe-based nanocrystalline FeCuNbSiB alloy are investigated as a function of the dc bias magnetic field. The experimental results show that the piezomagnetic coefficient of FeCuNbSiB is about 2.1 times higher than that of Terfenol-D at the low dc magnetic bias $H_{dc}$ = 46 Oe. Moreover, FeCuNbSiB has a large resonant dynamic strain coefficient at quite low Hdc due to a high mechanical quality factor, which is 3-5 times greater than that of Terfenol-D at the same low $H_{dc}$. Based on such magnetostriction characteristics, we fabricate a new type of transducer with FeCuNbSiB/PZT-8/FeCuNbSiB. Its maximum resonant magnetoelectric voltage coefficient achieves ~10 V/Oe. The ME output power reaches 331.8 ${\mu}W$ at an optimum load resistance of 7 $k{\Omega}$ under 0.4 Oe ac magnetic field, which is 50 times higher than that of the previous ultrasonic-horn-substrate composite transducer and it decreases the size by nearly 86%. The performance indicate that the FeCuNbSiB/PZT-8/FeCuNbSiB transducer is promising for application in highly efficient magnetoelectric energy conversion.

A High-efficiency Single-phase Photovoltaic Inverter for High-voltage Photovoltaic Panels (고전압 태양광 패널용 고효율 단상 태양광 인버터)

  • Hyung-Min, Ryu
    • Journal of IKEEE
    • /
    • v.26 no.4
    • /
    • pp.584-589
    • /
    • 2022
  • For DC-AC power conversion from a high-voltage photovoltaic panel to a single-phase grid, the two-stage transformerless inverter with a buck-boost converter followed by a full-bridge inverter is widely used. To avoid an excessive leakage current due to the large parasitic capacitance of the photovoltaic panel, the full-bridge inverter can only adopt the bipolar PWM which results in much higher power loss compared to the unipolar PWM. In order to overcome such a poor efficiency, this paper proposes a new topology in which an IGBT and a diode for circuit isolation are added to the buck-boost converter. The proposed circuit isolation method allows the unipolar PWM in the full-bridge inverter without any increase in the leakage current so that the overall efficiency can be improved. The validity of the proposed solution is verified by computer simulation and power loss calculation.

Feed System Modeling of Railroad using Fuel Cell Power Generation System (연료전지 발전시스템을 이용한 철도급전계통 모델링)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.195-200
    • /
    • 2020
  • With the growing interest in fossil fuel depletion and environmental pollution, railroad cars operating in Korea are in progress as the conversion from diesel to electric vehicles expands. The photovoltaic system, which is applied as an example of the conversion of electric vehicles, is infinite and pollution-free, and can produce energy without generating hazards such as air pollution, noise, heat, and vibration, and maintain fuel transportation and power generation facilities. There is an advantage that is rarely needed. However, the amount of electricity produced depends on the amount of solar radiation by region, and the energy density is low due to the power generation of about 25㎡/ kWp, so a large installation area is required and the installation place has limited problems. In view of these problems, many studies have been applied to fuel cells in the railway field. In particular, the plan to link the fuel cell power generation system railroad power supply system must be linked to the power supply system that supplies power to the railroad, unlike solar and wind power. Therefore, it has a close relationship with railroad cars and the linkage method can vary greatly depending on the system topology. Therefore, in this paper, we study the validity through simulation modeling related to linkage analysis according to system topology.

Detailed Design of Power Conversion Device Hardware for Realization of Fuel Cell Power Generation System (연료전지 발전시스템 구현을 위한 전력변환장치 하드웨어 세부설계)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.135-140
    • /
    • 2022
  • In addition to the stack that directly generates electricity by the reaction of hydrogen and oxygen, the fuel cell power generation system has a reformer that generates hydrogen from various fuels such as methanol and natural gas. It also consists of a power converter that converts the DC voltage generated in the stack into a stable AC voltage. The fuel cell output of such a system is direct current, and in order to be used at home, an inverter device that converts it into alternating current through a power converter is required. In addition, a DC-DC step-up converter is used to boost the fuel cell voltage to about 30~70V, which is the inverter operating voltage, to about 380V. The DC-DC step-up converter is a DC voltage variable device that exists between the fuel cell output and the inverter. Accordingly, since a constant output voltage of the converter is generated in response to a change in the output voltage of the fuel cell, the inverter can receive constant power regardless of the voltage change of the fuel cell. Therefore, in this paper, we discuss the detailed hardware design of the full-bridge converter, which is the main power source of the inverter that receives the fuel cell output voltage (30~70V) as an input and is applied to the grid among the members of the fuel cell power generation system.

Purification and Characterization of Lactate Dehydrogenase Isozymes in Channa argus (가물치(Channa argus) 젖산탈수소효소 동위효소들의 정제 및 특성)

  • Park, Eun-Mi;Yum, Jung-Joo
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.260-268
    • /
    • 2010
  • The lactate dehydrogenase (EC 1.1.1.27, LDH) isozymes in tissues from Channa argus were purified and characterized by biochemical, immunochemical and kinetic methods. The activity of LDH in skeletal muscle was the highest at 380.4 units and those in heart, eye and brain tissues were 13.4, 3,5 and 5.4 units, respectively. Citrate synthase (EC 4.1.3.7, CS) activity in heart tissue was the highest at 20.7 units. LDH/CS in skeletal muscle, heart, eye and brain tissues were 172.9, 0.6, 0.32 and 0.47. Protein concentration in skeletal muscle tissue was 14.7 mg/g and specific activities of LDH in skeletal muscle, heart, eye and brain tissues were 25.88, 0.79, 0.31 and 1.38 units/mg, respectively. Therefore, skeletal muscle tissue was anaerobic and heart tissue was aerobic. The LDH isozymes in tissues were identified by polyacrylamide gel electrophoresis, immunoprecipitation and Western blot with antiserum against $A_4$, $B_4$, and eye-specific $C_4$. LDH $A_4$, $A_3B$, $A_2B_2$. $AB_3$ and $B_4$ isozymes were detected in every tissue, $C_4$, $AC_3$, $A_2C_2$ and $A_3C$ were detected in eye tissue, and $A_3C$ was found in brain tissue. LDH $A_4$, $A_3B$, $A_2B_2$, $AB_3$, $B_4$, eye-specific $C_4$ isozymes were purified by affinity chromatography and Preparative PAGE Cells. The LDH $A_4$ isozyme was purified in the fraction from elution with $NAD^+$ containing buffer of affinity chromatography. Eye-specific $C_4$ isozyme was eluted right after $A_4$, after which $B_4$ isozyme was eluted with plain buffer. As a result, one part of molecular structures in $A_4$, $B_4$ and eye-specific $C_4$ were similar, but were different from each other in $B_4$ and $C_4$. Therefore the subunit A may be conservative in evolution, and the evolution of subunit B seems to be faster than that of subunit A. The activity of LDH $A_4$, $A_2B_2$, $B_4$, and eye-specific $C_4$ isozymes remained at 39.98, 21.28, 19.67 and 16.87% as a result of the inhibition by 10 mM of pyruvate, so the degree of inhibition was very high. The $Km^{PYR}$ values were 0.17, 0.27 and 0.133 mM in $A_4$, $B_4$ and eye-specific $C_4$ isozymes, respectively. The optimum pH of LDH $A_4$, $B_4$, eye-specific $C_4$, $A_2B_2$, $A_3B$, and $AB_3$ were pH 6.5, pH 8.5, pH 5.5, pH 6.0-6.5, pH 5.0 and pH 7.5. The $A_4$ and heterotetramer isozymes stabilized a broad range of pH. Especially, LDH activities in skeletal muscle tissue were high, resulting in a high degree of muscle activity.LDH metabolism in eye tissue seems to be converted faster from pyruvate to lactate by eye-specific $C_4$ isozyme as eye-specific $C_4$ have the highest affinity for pyruvate, and right after the conversion, oxidation of lactate was induced by $A_4$ isozyme. It was found that expression of Ldh-C, affinity to substrate and reaction time of $C_4$ isozyme were different according to the ecological environmental and feeding capturing patterns.

Economic and Environmental Assessment of a Renewable Stand-Alone Energy Supply System Using Multi-objective Optimization (다목적 최적화 기법을 이용한 신재생에너지 기반 자립 에너지공급 시스템 설계 및 평가)

  • Lee, Dohyun;Han, Seulki;Kim, Jiyong
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.332-340
    • /
    • 2017
  • This study aims to propose a new optimization-based approach for design and analysis of the stand-alone hybrid energy supply system using renewable energy sources (RES). In the energy supply system, we include multiple energy production technologies such as Photovoltaics (PV), Wind turbine, and fossil-fuel-based AC generator along with different types of energy storage and conversion technologies such as battery and inverter. We then select six different regions of Korea to represent various characteristics of different RES potentials and demand profiles. We finally designed and analyzed the optimal RES stand-alone energy supply system in the selected regions using multiobjective optimization (MOOP) technique, which includes two objective functions: the minimum cost and the minimum $CO_2$ emission. In addition, we discussed the feasibility and expecting benefits of the systems by comparing to conventional systems of Korea. As a result, the region of the highest RES potential showed the possibility to remarkably reduce $CO_2$ emissions compared to the conventional system. Besides, the levelized cost of electricity (LCOE) of the RES-based energy system is identified to be slightly higher than conventional energy system: 0.35 and 0.46 $/kWh, respectively. However, the total life-cycle emission of $CO_2$ ($LCE_{CO2}$) can be reduced up to 470 g$CO_2$/kWh from 490 g$CO_2$/kWh of the conventional systems.

The Long-term Results of a Modified Maze Procedure with Using Cryoablation (냉동 절제를 이용한 변형된 Maze술 식의 중장기 결과)

  • Park, Kwon-Jae;Woo, Jong-Soo;Bang, Jung-Hee
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.710-717
    • /
    • 2008
  • Background: Atrial fibrillation is associated with several complications such as cerebro-vascular accidents and peripheral arterial embolism. Most of the patients who have this arrhythmia chronically feel their heart beating and so they are frightened; therefore, the quality of a patient's life is decreased. The purpose of this article is to determine the long term results of a modified Maze procedure and the factors that influence the success of the procedure. Material and Method: This study enrolled 88 patients who underwent the modified Maze with using cryoablation between June, 2001 and February, 2007. The 88 consecutive patients were divided into two groups ac cording to how the pulmonary veins were isolated, that is, with or without cryoablation. There were 58 patients who were isolated by cutting and sewing in the right pulmonary veins and by cyroablation in the left pulmonary veins in group 1 (group 1, n=58), and 30 patients who underwent isolation by cryoablation in the right & left pulmonary veins were placed in group 2 (group 2, n=30). The ECG was checked at discharge to determine the sinus conversion rate and we followed up the patients to determine whether or not the patients maintained sinus rhythm. We also checked the ECG at the last visit to determine the patients' heart rhythm. Result: The mean follow up time was $44.3{\pm}19.2$ months. At discharge, 72.4% of the patients in group 1 were in proper sinus rhythm and 66.7% of the patients in group 2 were in proper sinus rhythm. At the last follow up, 81% of the patients in group 1 were in normal sinus rhythm and 60% of the patients in group 2 were in normal sinus rhythm. When we analyzed the data via the Kaplan-Meier method, 86.5% of the patients were free from atrial fibrillation (% free from AF) at 1 year, 80% of the patients were free from atrial fibrillation at 5 year in group 1 and 70% of the patients were free from atrial fibrillation at 1 year and 51 % of the patients in group 2 were free from atrial fibrillation at 5 year. Conclusion: The modified Maze technique using cryoablation was a simple and effective procedure. But the success rate of the Maze technique using cryoblation is lower than that of the standard Maze III. The method using cryoablation shorten the operation time, but we must conduct more studies to get a better result of the modified Maze technique with using cryoablation.