• Title/Summary/Keyword: Abutments

Search Result 423, Processing Time 0.022 seconds

Long term earth pressure behavior behind stub abutment (난쟁이 교대배면의 장기 토압거동)

  • 박영호;정경자;김낙영;황영철
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.779-786
    • /
    • 2002
  • To find a long term horizontal movement of superstructure caused by seasonal thermal change, several types of gages are installed such as soil earth pressuremeter behind stub abutment and jointmeter between approach slab and relief slab. As results, maximum passive earth pressure behind integral bridge abutments centerline with lateral movement of superstructure is about 1/6 of classic Rankine's earth pressure. And its distribution is not triangular but rectangular shape due to shape behind integral bridge abutments.

  • PDF

A useful method of using the healing abutments for interocclusal records in implant overdenture: a case report

  • Choi, Hyunsuk;Kang, Sohee
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.4
    • /
    • pp.341-343
    • /
    • 2022
  • To determine the vertical dimension and centric relation during the construction of implant overdentures, the record base and wax rim may need to be adjusted. The conventional method has several drawbacks, as it requires repeated tightening and loosening of the impression coping. Here, we report a useful and novel method for interocclusal records using the healing abutments in implant overdentures. Our case demonstrates that this method is easier and simpler and prevents gingival collapse.

A Study on Lateral Movement of Bridge Abutment on Soft Ground (연약지반상 교대의 측방이동에 관한 연구)

  • 홍원표;한중근
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.53-66
    • /
    • 1994
  • In case of using pile foundation to support bridge abutments on soft ground, the soft ground often causes serious troubles such as lateral movement of the bridge abutments. The foundation piles in soil undergoing lateral movement is one of the typical passive piles. However, Generally, on design of the piles for abutments, the piles have not been considered as a passive piles; sofar:. Because it is difficult to assess the effect of the lateral movement on the desigin and reasonable design method is not established yet. In this study, several abutments, of which lateral movement was taken place, was investigated. Based on the investigation a criterion was presented to assess the lateral movement of the soft soil under backfill for abutment. By use of the criterion, the lateral movement of abutment could be predicted. As the results of thin study, it was anon that the lateral movement of abutment could be occured when the safety factor of slope stability is lese than either 1.5(without the pile effect) or 1.8 (with the pile effect). Especially, excessive lateral movements were occurred when the safety factor of slope stability is less than either 1.0(without the pile effect) or 1.1 (with the pile effect).

  • PDF

FINITE ELEMENT ANALYSIS OF STRESS PATTERNS ON PERIODONTIUM OF SPLINTED ABUTMENTSFOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (후방연장 국소의치에서 지대치의 splinting에 따른 치주조직의 응력 변화에 관한 유한요소법적 연구)

  • Hwang, Jae-Woong;Chang, Ik-Tae;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.241-268
    • /
    • 1995
  • Splint therapy, the immobilization of teeth, has been done for patient's masticatory comforts and an adjunctive aid in periodontal therapy. Mandibular premolars are frequently splinted in many distal extension removable partial denture cases. But splinting is an extensive restoration that may not be conservative of tooth structure and may prove to be quite costly to the patient. The two dimensional finite element analysis method was used to determine the magnitude and mode of distribution of the stresses of the periodontal ligament and supporting alveolar bone when abutments with different periodontal supports were splinted and distal-extension removable partial denture was subjected to different loading schemes. The results were as follows : 1. When abutments were splinted, stresses moved from apico-distal to apico-mesial of terminal abutment on a vertical force and from disto-alveolar crest to apex on a distally directed force. But stresses were generally diminished on a mesially directed force. 2. As vertical bone loss was proceeding, most of stresses were transmitted to residual ridge and the rest of stresses were concentrated on apex of distal abutment. But these apical stresses were minimized when abutments were splinted. 3. As mesially inclined bone loss was proceeding, it seemed to be dangerous that many stresses were concentrated on the distal alveolar crest, especially in the distally directed load case. Abutments splinting decreased the alveolar crestal stresses but not enough. 4. For all vertical stresses were effectively decreased on splinting, stresses were concentrated as highly on apico-mesial area of distal abutment in distally directed load cases as the distal inclination of bone level was severe. 5. The directions and magnitudes of abutment movements were decreased with teeth splinting.

  • PDF

A COMPARATIVE STUDY ON THE ACCURACY OF IMPRESSION METHOD USING ADDITION SILICONE PUTTY IMPRESSION MATERIAL (부가중합형 Silicone putty 인상재를 이용한 인상채득 방법의 정확성에 관한 연구)

  • Je, Hong-Ji;Jeong, Chang-Mo;Jeon, Young-Chan;Hwang, Hie-Seong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.373-383
    • /
    • 1996
  • In order to compare the accuracy of impression method using addition silicone putty impression material, metal master die was fabricated with 4 cylindrical abutments that were similar in shape to mandibular arch. Among the 4 abutments, two(A, D) with 8mm width and 7mm height were formed in the 2nd molar regions and the other two(B, C) with 6mm width and 7mm height were on the canine regions. Impressions were taken using one-step putty wash impression technique and two-step putty wash impression technique by three different types of impression materials(Perfect, Express, Exaflex). Upon measuring the distance between the abutments on the model by three dimensional measuring machine, the percent of devitaion of the materials were obtained, rendering the following results. The results obtained are as follows : 1. There was no significant difference in accuracy in regard with the impression method between one-step putty wash impression technique and two-step putty wash impression technique using addition silicone putty impression material. 2. There were no difference in accuracy among with three different addition silicone putty impression materials. 3. All the distances between abutments on improved stone models increased in comparison with those on the metal master model.

  • PDF

A STUDY OF THE STRESS DISTRIBUTION ON THE SECOND ABUTMENT AND SUPPORTING TISSUES IN FIXED PARTIAL DENTURE USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (고정성 가공의치에서 이차 지대치에 발생하는 응력의 삼차원 유한요소법적 분석)

  • Kim, Jeong-Hee;Jo, Kwang-Hun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.675-694
    • /
    • 2000
  • The purpose of this study was to investigate the displacement of and the stress distribution on the prosthesis, abutment, and its supporting tissues under functional load, and the effect of alteration in root length of 2nd abutment. The 3-dimensional finite element method was used and the finite element models were prepared in which the abutments of left mandibular 5 unit axed partial denture were canine, the 1st pre-molar and the 2nd molar, and the root lengths of canines were as follows. Model I : Root length of canine was 2mm longer than the 1st premolar Model II : Root length of canine was 2mm shorter than the 1st premolar Static compressive force of 300N was applied to connector between 2nd premolar & 1st molar, and then von Mises stress, displacement and reaction force were obtained. The results were as follows : 1. In fixed partial denture, prosthesis under load on pontic was rotated around mesio-distal long axis of it from longual side to buccal, and simultaneously bended in buccal and gingival direction with mesial end deformed in gingival direction and distolingual end in occlusal. 2. Clinical crowns of abutments were bended in the same directions with those in which prosthesis deforms. Due to that, roots of anterior abutments were twisted in counterclockwise with concentration of shear stress on distal or distobuccal sides of their cervices, and that of posterior was in clockwise with concentration of shear stress on mesiobuccal side of it in the same level with anterior abutments. 3. In case that root length of the 2nd abutment was longer than that of the 1st abutment, its displacement and reaction force which means the force tooth exerts on the surrounding periodontal tissues were smaller but shear stress on itself was larger than in the case root length of 2nd abutment was shorter.

  • PDF

The Stability of Foundation Piles for Abutment (교대기호말뚝의 안정)

  • 홍원표;안종필
    • Geotechnical Engineering
    • /
    • v.7 no.2
    • /
    • pp.67-82
    • /
    • 1991
  • When bridge abutments are constructed on pile foundations in unstable slope, horizontal deflections may be developed in the piles and the abutments due to lateral soil movements arisen from backfills. In most of the above mentioned cases, the piles are situated in a soft layer where lateral earth pressures are developed between the piles and the soils. The undesirable lateral earth pressures decreases the stability of the piles. However, the piles may have a preventive effect against lateral soil movements and improve the stability of the slope. For the stability problem of such slope containing piles in a row, two kinds of analyses for the slope-stability and the pile-stability have to be performed. The whole stability of bridge abutments on pile foundation can be obtained only by the stabilization for both the slope and the piles. A reasonable analytical method for the bridge abutments on pile foundation was established in this study By use of the analytical method for an example, several factors which influence affect the stability of bridge abutment were investigated. Finally, for the bridge abutment subjected to lateral deflections damage, the fixity condition of pile head was investigated.

  • PDF

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.

Evaluation of the reproducibility of various abutments using a blue light model scanner

  • Kim, Dong-Yeon;Lee, Kyung-Eun;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.328-334
    • /
    • 2018
  • PURPOSE. To evaluate the reproducibility of scan-based abutments using a blue light model scanner. MATERIALS AND METHODS. A wax cast abutment die was fabricated, and a silicone impression was prepared using a silicone material. Nine study dies were constructed using the prepared duplicable silicone, and the first was used as a reference. These dies were classified into three groups and scanned using a blue light model scanner. The first three-dimensional (3D) data set was obtained by scanning eight dies separately in the first group. The second 3D data set was acquired when four dies were placed together in the scanner and scanned twice in the second group. Finally, the third 3D data set was obtained when eight dies were placed together in the scanner and scanned once. These data were then used to define the data value using third-dimension software. All the data were then analyzed using the non-parametric Kruskal-Wallis H test (${\alpha}=.05$) and the post-hoc Mann-Whitney U-test with Bonferroni's correction (${\alpha}=.017$). RESULTS. The means and standard deviations of the eight dies together were larger than those of the four dies together and of the individual die. Moreover, significant differences were observed among the three groups (P<.05). CONCLUSION. With larger numbers of abutments scanned together, the scan becomes more inaccurate and loses reproducibility. Therefore, scans of smaller numbers of abutments are recommended to ensure better results.

THE EFFECT OF THE DIFFERENCE OF THE IMPLANT FIXTURE AND ABUTMENT DIAMETER FOR STRESS DISTRIBUTION (임프란트 고정체와 지대주 직경의 차이가 응력분포에 미치는 영향)

  • Jung Jong-Won;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.583-596
    • /
    • 2004
  • Statement of problem : Stress concentration on the neck bone affects the bone resorption, and finally the implant survival. Purpose: In order to examine the stress distribution on the neck bone and prosthesis abutment for implants, decreasing abutment sizes were used. Material and methods : Axisymmetric models were used to obtain the data required. These models were composed of 4mm implants with 3.4mm and 4mm abutments, 5mm implants with 3.4mm and 5mm abutments and 6mm implants with 3.4mm and 6mm abutments. All abutments were designed to received a 10mm high by 10mm diameter gold crown. Functional element analysis was used to obtain these results using data that consisted of 50 N vertical and 45 degree inclination forces. Results : 1. Changing the diameter of the abutment on the implant affects the effect of the inclination forces more than the effect of the vortical forces. 2. Changing the diameter of the abutment on the implant affect the effect of the inclination forces more than the effect of the vertical forces. 3. Experimentation showed that the larger diameter implants provided a decreased neck bone stress, whereas a larger diameter abutment provided a decrease marginal abutment stress. 4. Experimentation showed that the neck bone and abutment received more stress from inclination forces than vertical forces, Conclusions: By decreasing the size of the abutment on the implant we were able to diminishneck bone stress.