• 제목/요약/키워드: Abutments

검색결과 423건 처리시간 0.026초

Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

  • Rodiger, Matthias;Rinke, Sven;Ehret-Kleinau, Fenja;Pohlmeyer, Franziska;Lange, Katharina;Burgers, Ralf;Gersdorff, Nikolaus
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.233-240
    • /
    • 2014
  • PURPOSE. To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS. Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: $5.7^{\circ}$; customized-long, height: 6.79 mm, taper: $4.8^{\circ}$; customized-short, height: 4.31 mm, taper: $4.8^{\circ}$) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: $5.7^{\circ}$) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS. Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION. No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

Transverse seismic response of continuous steel-concrete composite bridges exhibiting dual load path

  • Tubaldi, E.;Barbato, M.;Dall'Asta, A.
    • Earthquakes and Structures
    • /
    • 제1권1호
    • /
    • pp.21-41
    • /
    • 2010
  • Multi-span steel-concrete composite (SCC) bridges are very sensitive to earthquake loading. Extensive damage may occur not only in the substructures (piers), which are expected to yield, but also in the other components (e.g., deck, abutments) involved in carrying the seismic loads. Current seismic codes allow the design of regular bridges by means of linear elastic analysis based on inelastic design spectra. In bridges with superstructure transverse motion restrained at the abutments, a dual load path behavior is observed. The sequential yielding of the piers can lead to a substantial change in the stiffness distribution. Thus, force distributions and displacement demand can significantly differ from linear elastic analysis predictions. The objectives of this study are assessing the influence of piers-deck stiffness ratio and of soil-structure interaction effects on the seismic behavior of continuous SCC bridges with dual load path, and evaluating the suitability of linear elastic analysis in predicting the actual seismic behavior of these bridges. Parametric analysis results are presented and discussed for a common bridge typology. The response dependence on the parameters is studied by nonlinear multi-record incremental dynamic analysis (IDA). Comparisons are made with linear time history analysis results. The results presented suggest that simplified linear elastic analysis based on inelastic design spectra could produce very inaccurate estimates of the structural behavior of SCC bridges with dual load path.

성견에서 Titanium Plasma Sprayed IMZ 임플란트에 가해진 조기 기능하중의 골유착 및 골형성에 미치는 영향 (EFFECTS OF EARLY FUNCTIONAL LOADING ON BONE FORMATION AROUND TITANIUM PLASMA SPRAYED IMZ IMPLANTS IN DOGS)

  • 전영식;한동후
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.550-568
    • /
    • 1995
  • The purpose of this study was to observe the effects of early functional on bone formation around titanium plsama sprayed IMZ implants. 15 IMZ implants were inserted on the mandibular premolar areaa in 5 mondgrel dogs. The inplants were divided into 4 groups according to it’s loading schedule : Temporary abutments were connected for functional loading 6weeks, 9weeks, and 12weeks after implants installation in group I, II, and III, respectively. Abutments were not connected in the control group. After polyfluorochrome sequential labeling, all animals were sacrificed and bone sections includig implants and the 1st. molar were removed and processed for histologic evaluation. From light and fluorescence microscopic evaluation as well as histomorphometric and EPMA analysis, following results were obtained : 1. Light microscopically, the osteoid tissues were observed much in the compact bone of unloaded group, and cancellous bone formation observed more in early loaded group. 2. Calcification and remodeling of bone took place faster in loaded group, especially in 6 weeks group. 3. Moderate to severe marginal bone resorption was observed in 6 weeks group, mainly on buccal crest. 4. There was no difference in the percentages of bone-to-metal contact among the experimental groups. 5. In quantitative analysis using EPMA, there was no difference in the content of calcium and phosphorus among the experimental groups, regardless of distance.

  • PDF

Free-Standing $Br{\aa}nrmark$ Osseointegrated Implants와 Two-part I.T.I. Dental Implants(Benefit)를 이용한 하악 양측 대구치 결손 수복에 관한 임상적 연구(I) (FIXED/REMOVABLE RECONSTRUCTION IN PARTIALLY EDENTULOUS PATIENT USING $Br{\aa}nrmark$ OSSEOINTEGRATED IMPLANTS AND TWO-PART I.T.I. IMPLANTS(BONEFIT) AS ABUTMENTS)

  • 양재호
    • 대한치과보철학회지
    • /
    • 제31권1호
    • /
    • pp.151-162
    • /
    • 1993
  • The author installed $3.75mm\times10mm$ $Br{\aa}nrmark$ osseointegrated implants and $3.5mm\times8mm$ I.T.I. hollow screw implants(Benefit) as a free standing abutment to replace lower left and right molars of 44-year-old female patient. Form the foregoing procedure, the author obtained the following results. 1. Free-standing $Br{\aa}nrmark$ and I.T.I. Hollow screw implants(Benefit) could be used to replace molars effectively without reduction of adjacent natural teeth, 2. Rotation of occlusal gold screw of $Br{\aa}nrmark$ implants was observed under occlusal force. 3. Adjustment of height of I.T.I. abutments was necessary in the mandibular second molar because of the limited occlusal clearance. 4. Form the oral examination, patient comments, panoramic and periapical radiographs, there were no pain, gingival imflammation and mobility, but slight reduction of alveolar bone level was shown around both implant systems. 5. Patient comments were comfortable on both systems. but the patient complained about economic problem of $Br{\aa}nrmark$ system and long treatment treatment time of both systems.

  • PDF

방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례 (Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report)

  • 최은주;조혜원
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.218-224
    • /
    • 2017
  • 방사선치료를 받은 상악에 임플란트 지지 고정성 보철물을 이용하여 수복하는 것은 골치유능력이 낮기 때문에 상세한 치료계획이 필요하다. All-on-4 개념에 의한 임플란트 식립은 골이식을 피하면서 임플란트를 매식할 수 있어 유리하다. 일반적으로 경사된 임플란트에는 기성 경사형 지대주를 사용해왔다. 본 임상증례에서는 computer-aided design and computer-aided manufacturing (CAD/CAM)으로 제작된 지대주를 사용하였다. 본 증례는 all-on-4 개념에 의해 임플란트를 매식하고 CAD/CAM titanium 지대주를 제작한 다음 CAD/CAM zirconia 고정성 보철물로 수복하여 좋은 결과를 얻었기에 보고하고자 한다.

제주향교의 조영적 특성에 관한 연구 (A Study on the Constructional Characteristics of Jeju-HyangGyo)

  • 지태승;박정근;박철민
    • 한국농촌건축학회논문집
    • /
    • 제10권3호
    • /
    • pp.59-66
    • /
    • 2008
  • This study was performed to ascertain how HyangGyos based on national ideology were built in Jeju Island and what their detailed styles are. In Jeju-HyangGyo, unique architectural characteristics are shown as they have been built in an island independent from the mainland. Also up-down system was well reflected in detailed architectural styles. The main temple of Jeju-HyangGyo was built in the type of one-Chulmok(a subsidiary material of Gongpo and a piece of wood to support the eaves) of which ancon supports a purline from the center of a pillar and two-Ikgong(a piece of wood engraved to put on an ancon), but in the case of the lecture hall, its Gongpo(a piece of wood to support the eaves) was inferior in quality. In the case of Jeju abutments were used in main temples and fire walls were mostly used. In particular, their abutments are difficult to be observed in HyangGyo in the mainland. It is presumed that the abutment and the fire wall used in Jeju Island might be the best solution to protect structures from rain and moisture. To sum up, local characteristics and traditional rules were thoroughly reflected in Jeju-HyangGyos built in Jeju Island from the aspect of arrangement and detailed style. In conclusion, it is significant that architectural styles, not to mention the other aspects of Jeju culture, were suitably adapted to Jeju Island.

  • PDF

LRFD 설계를 위한 교대의 신뢰성 해석 모델 (Reliability Analysis Modeling for LRFD Design of Bridge Abutments)

  • 엄준식
    • 한국지반공학회논문집
    • /
    • 제30권8호
    • /
    • pp.5-11
    • /
    • 2014
  • 본 연구의 목적은 신뢰성해석을 통해 교량의 하부구조인 교대에 대해 주요설계변수와 신뢰성계수의 관계를 정립하여 하중저항계수설계를 위한 신뢰성해석방법을 개발하는 것이다. 하중조건으로는 사하중, 연직토압 및 수평토압, 상재하중, 그리고 통행차량에 의한 활하중을 고려하였다. 고려한 하중에 대해 지반의 허용지지력, 전도, 활동 등을 반영하는 한계상태함수를 정의하여 신뢰성 해석을 몬테-카를로 시뮬레이션을 이용하여 수행하였다. 신뢰성 해석 결과 신뢰성지수에 가장 큰 영향을 미치는 인자는 내부마찰각이었으며 민감도해석 결과 신뢰성 지수는 저항계수와 수평토압의 변화에 따라 민감하게 변화하는 것을 알 수 있었다.

The reliability of an easy measuring method for abutment convergence angle with a computer-aided design (CAD) system

  • Seo, Yong-Joon;Kwon, Taek-Ka;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권3호
    • /
    • pp.185-193
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate the intra-rater reliability and inter-rater reliability of three different methods using a drawing protractor, a digital protractor after tracing, and a CAD system. MATERIALS AND METHODS. Twenty-four artificial abutments that had been prepared by dental students were used in this study. Three dental students measured the convergence angles by each method three times. Bland-Altman plots were applied to examine the overall reliability by comparing the traditional tracing method with a new method using the CAD system. Intraclass Correlation Coefficients (ICC) evaluated intra-rater reliability and inter-rater reliability. RESULTS. All three methods exhibited high intra-rater and inter-rater reliability (ICC>0.80, P<.05). Measurements with the CAD system showed the highest intra-rater reliability. In addition, it showed improved inter-rater reliability compared with the traditional tracing methods. CONCLUSION. Based on the results of this study, the CAD system may be an easy and reliable tool for measuring the abutment convergence angle.

Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner

  • Kim, Dong-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.210-217
    • /
    • 2020
  • PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax cast abutment dies were fabricated. Each of the silicone impression was produced using the replicable silicone. Each study die was constructed from the prepared replicable stone used for scans. 3-dimensional data was obtained after scanning the prepared study dies for the repeatability by using the blue light scanner. The prepared 3-dimensional data could have the best fit alignment using 3-dimensional software. For reproducibility, each abutment was used as the first reference study die, and then it was scanned five times per each. 3-dimensional software was used to perform the best fit alignment. The data obtained were analyzed using a nonparametric Kruskal-Wallis H test (α=.05), post hoc Mann-Whitney U test, and Bonferroni correction (α=.017). RESULTS. The repeatability of 0°, 6°, and 10° abutments was 3.9, 4.4 and 4.7 ㎛, respectively. Among them, the 0° abutment had the best value while the 10° abutment showed the worst value. There was a statistically significant difference (P<.05). The reproducibility of 0°, 6°, and 10° abutments was 6.1, 5.5, and 5.3 ㎛, respectively. While the 10° abutment showed the best value, the 0° abutment showed the worst value. However, there was no statistically significant difference (P>.05). CONCLUSION. In repeatability, the 0° abutment showed a positive result. In reproducibility, the 10° abutment achieved a positive result.