• 제목/요약/키워드: Absorption test

검색결과 1,433건 처리시간 0.027초

발전기 고정자 권선의 정전용량 측정을 통한 흡습 진단 방법에 관한 연구 (A Study on the Water Absorption Diagnosis Method through Capacitance Measurement for Generator Stator Windings)

  • 김희수;배용채;기창두
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.50-57
    • /
    • 2006
  • The water leak in water-cooled generator stator windings can generate the serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them for the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. The developed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

낙하충격실험을 통한 고무의 충격흡수성능과 전단계수 평가 (Determination of Shock Absorption Performance and Shear Modulus of Rubbers by Drop Impact Test)

  • 강동환;서무열;김학인;김태원
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.321-328
    • /
    • 2009
  • Shock absorption performances of various rubbers were investigated by using drop impact test. Several types of rubber such as NR, NBR, EPDM, SR and PUR with three respective levels of shore hardness were used for the test. As in the cases, the absorbed impact energies in rubbers were measured under seven different loads against impact energy between 5-80J. The impact absorption efficiencies of the rubbers then were evaluated by means of both single impact energy condition and summation of all impact energy applied condition. As shown in the results, PUR and EPDM have better shock absorption performances than other rubbers. Further analysis was extended to determine a shear modulus of SR through the finite element implementation with Blatz-Ko model. As can be seen, relatively higher level of absorption energy results in a decreasing shear modulus.

여러 가지 확률분포를 이용한 발전기 고정자 권선의 흡습 시험에 관한 연구 (A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions)

  • 김희수;배용채;김희정;나명환
    • 응용통계연구
    • /
    • 제22권5호
    • /
    • pp.961-969
    • /
    • 2009
  • 발전기 고정자 권선의 냉각수 누수는 발전기 운전 중 절연 파괴를 발생시켜 발전소 불시정지를 발생시킬 뿐만 아니라 권선 손상에 따른 정비 기간 및 비용이 매우 많이 소요된다. 따라서 발전기 고정자 권선의 냉각수 누수가 발생하였을 때 재앙이 일어나기 전에 고정자 권선 절연물의 흡습 상태를 진단하는 것은 예방 정비 측면에서 매우 효과적인 정비 방안이라고 할 수 있겠다. 본 논문에서는 발전기 고정자 권선에 흡습여부를 알아보기 위하여 여러 가지 확률분포를 이용하여 판정기준값을 유도하였다. 또한, 유도된 판정기준값을 바탕으로 실제 관측된 자료를 이용하여 흡습여부를 판단하였다.

승용차(乘用車) 재활용(再活用) 범퍼의 충격흡수(衝擊吸收) 성능(性能)에 관(關)한 연구(硏究) (A study on Shock Absorption Performance of Reused Bumper for Passenger Cars)

  • 김지원;이창식
    • 자원리싸이클링
    • /
    • 제18권1호
    • /
    • pp.44-51
    • /
    • 2009
  • 이 연구는 신개발 범퍼의 충격흡수성능 시험기준을 적용하여 재활용 범퍼의 충격흡수성능을 실험하고, 재활용 범퍼의 성능 특성을 비교한 것이다. 본 연구에서 적용된 범퍼는 유형이 다른 두 종류의 승용차 외장 범퍼를 선정하여 2종류의 재활용 범퍼를 자동차 안전 기준에 따라 충격흡수성능을 시험하였다. 재활용 범퍼의 충격 흡수성능 실험 결과 2.5마일 범퍼 충격 성능 특성은 동일한 차종의 신품 범퍼의 충격 성능 및 흡수 성능 특성과 거의 동등수준의 충격 성능 특성을 나타내었다.

탄성형 에폭시의 흡습에 따른 전기적인 특성 (Electrical Properties according to Moisture Absorption of Elastomer Epoxy Resin)

  • 박재열;박성희;이강원;강성화;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1155-1158
    • /
    • 2003
  • In this paper, we studied on the electrical characteristics of insulation material of elastomer epoxy. As the results of test, properties of epoxy represent differently according to elastomer contents. Also, its permittivity, tan ${\delta}$ and BDV(Break-Down Voltage) strength show big difference when those compare before moisture absorption test and after moisture absorption test. From this test we find results that mush elastomer contents can cause insulation properties to degrade.

  • PDF

보도용 연성 샌드 아스팔트 포장의 충격흡수 특성 평가 (Evaluation of Impact Energy Absorption Characteristics of Flexible Sand Asphalt Pavement for Pedestrian Way)

  • 최창정;동배선;김광우;김성운
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.31-41
    • /
    • 2019
  • More than 90% of roadway in the world are paved as asphalt concrete pavement due to its excellent properties compared with other paving materials; excellent riding quality, flexibility, anti-icing property and easy maintenance-ability. In this study, to make best use of the softer property of the asphalt mixture, the flexible sand asphalt mixture (FSAM) was developed for pedestrian ways. The mix design was conducted to prepare FSAM using PG64-22 asphalt, screenings (sand) less than 5mm, crumb rubber, hydrated lime and limestone powder without coarse aggregate. The deformation strength ($S_D$), indirect tensile strength (ITS) and tensile strength ratio (TSR) tests were conducted to make sure durability of FSAM performance. The impact energy absorption and flexibility were measured by drop-boll test and the resilient modulus ($M_R$) test. The impact energy absorption of FSAM was compared with normal asphalt pavement, concrete pavement, stone and concrete block for pedestrian way. As a result of drop-boll test, FSAM showed higher impact energy absorption compared with other paving materials with the range of 18% to 43%. Impact energy absorption of FSAM increased with increasing test temperature from 5 to $40^{\circ}C$. The results of $M_R$ test at $5^{\circ}C$ showed that the flexibility of FSPA was increased further, because the $M_R$ value of the sand asphalt was measured to be 38% lower than normal dense-graded asphalt mixture (WC-1). Therefore, it was concluded that the FSAM could provide a high impact absorbing characteristics, which would improve walking quality of the pedestrian ways.

FE 해석을 통한 충격흡수시설의 개발 (Development for Shock Absorption System by Using FE Analysis)

  • 강영호;김홍주;박동화;김계수;강범수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.224-229
    • /
    • 2000
  • This paper describe a (mite element computer simulation of a absorption system using full scale car crash test. The full scale test selected for this study is a 80kmh frontal, side and 25% offset impact of a 1993 Ford Taurus vehicle into a absorption system. This absorption system has external rubber and internal steel pannel. This simulation has completed for decision of these components energy absorption performance. Dynamical performance of this system and movement are obtained from this simulation. and then We can appreciate the safety of passenger from measure the vehicle C.G's acceleration.

  • PDF

Analysis of Leak and Water Absorption Test Results for Water-Cooled Generator Stator Windings

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Wook-Ryun;Lee, Doo-Young;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권2호
    • /
    • pp.230-235
    • /
    • 2012
  • Cases of insulation breakdown damage of water-cooled generator stator windings occur frequently due to coolant leakage and water absorption worldwide. Such serious accidents may cause not only enormous economic loss but also very serious grid accidents in terms of stable supply of electric power. More than 50 % of domestic generators have been operated for more than 15 years, and leak and water absorption problem of windings are often found during the planned preventive maintenance period. Since 2005, leak and water absorption tests have been performed for total watercooled stator windings after fully drying the inside of the windings. The results are then comprehensively analyzed. The result of the test performed by GE, a foreign manufacturer, for 141 generators showed failures in 80 of them (failure rate: 57 %), whereas in the tests carried out in Korean domestic power plants, only 14 out of 50 generators showed failures (failure rate: 28 %).