• Title/Summary/Keyword: Absorption power

Search Result 852, Processing Time 0.027 seconds

Prediction of Output Power for PV Module with Tilted Angle and Structural Design (태양광 모듈의 구조디자인과 설치각도에 따른 출력예측)

  • Ko, Jae-Woo;Yun, Na-Ri;Min, Yong-Ki;Jung, Tae-Hee;Won, Chang-Sub;Ahn, Hyung-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.371-375
    • /
    • 2013
  • A new model about output power prediction of PV module with various tilted angles and cell to cell distances has been proposed in this paper. Light intensity arrived on a solar cell could be changed by characteristics of PV module materials. Refractive indices, thickness and absorption coefficients of glass, EVA, solar cell and Backsheet are used to predict output. Also, the incident angle of light is changed 0 to 90[$^{\circ}$] and cell to cell distances are 5, 10 15[mm]. Two types of light incident on a solar cell are considered which are direct to a solar cell and reflected from Backsheet. The intensity of the incident light directly into the solar cell is reduced through glass and EVA about 17.5[%] in theoretical way. It has an error of 2.26[%] compared with experimental result. The results for compare theoretical with experimental data is validated within the error of 6.3[%]. This paper would be a research material to predict output power when the PV module is installed outdoor or a building.

Performance Improvement Using Real-Time Detection of Time-Variant Load Impedance of the Receiver in Wireless Power Transfer System (시간에 따라 변하는 수신단 부하 임피던스의 실시간 검출을 통한 무선 전력 전송시스템의 성능 개선)

  • Jang, Hyeong-Seok;Tae, Hyun-Sung;Kim, Kwang-Seok;Yeo, Tae-Dong;Oh, Kyoung-Sub;Yu, Jong-Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.6
    • /
    • pp.679-689
    • /
    • 2014
  • In this paper, an analysis of the effect of time-variant reflected impedance and its detection method on wireless power transfer(WPT) systems are presented. The reflected resistance at WPT systems is very important parameter as it indicates how well matched antenna is and will exhibit high efficiency. Proposed detection method is based on transmitter current variation analysis with respect to frequency sweep. Using the proposed design method, a wireless power transfer system operating at the frequency of 125 kHz, is design and detect reflected impedance variation. The proposed design method provides good agreements between measured and simulated results. Therefore, The proposed detecting method provides a nonintrusive method to detect harmful object in WPT system.

Performance of a Refrigerant Heating Type Heat Pump by Changing of Driving Devices and Heat Exchangers (구동장치 및 열교환기 변경에 따른 냉매가열식 열펌프의 성능특성)

  • Park, Youn-Cheol;Kim, Sang-Hyuk;Kim, Ji-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.49-56
    • /
    • 2008
  • When the outdoor air temperature decreased less than the freezing temperature, frost forms at the surface of heat exchangers and it makes the performance degradation of a heat pump system. In this study, a heat pump system has been developed which has a refrigerant heating device as an auxiliarly heating equipment. To reduce power consumptions of the system, a liquid pump, rather than a compressor, was used to drive refrigerant in the heat pump cycle. Ratio of refrigerant mass flow between a refrigerant heating heat exchanger(GHX) and a outdoor plate heat exchanger(PHX) was varied and the system performance was measured and analyzed. As results, when the refrigerant flow rate to the GHX was decreased, the system performance is decreased due to heat absorption capability restriction of the GHX and small variation of the power consumption in the compressor. The effect on the evaporating and condensing pressure by the distribution ratio of the refrigerant to the each heat exchanger is small compare to the effect by the frequency change in the compressor. When the compressor was replaced by the liquid pump, the capacity of the system decreased a little, however the power consumption decrease approximately 80% compare with the power used in the compressor.

Seismic Fragility Analysis Considering the Inelastic Behavior of Equipment Anchorages for High-Frequency Earthquakes (고진동수 지진에 대한 기기 정착부의 비탄성 거동을 고려한 지진취약도 평가)

  • Eem, Seunghyun;Kwag, Shinyoung;Choi, In-Kil;Jung, Jae-Wook;Kim, Seokchul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.261-266
    • /
    • 2021
  • Nuclear power plants in Korea were designed and evaluated based on the NRC's Regulatory Guide 1.60, a design response spectrum for nuclear power plants. However, it can be seen that the seismic motion characteristics are different when analyzing the Gyeongju earthquake and the Pohang earthquake that has recently occurred in Korea. Compared to the design response spectrum, seismic motion characteristics in Korea have a larger spectral acceleration in the high-frequency region. Therefore, in the case of equipment with a high natural frequency installed in a nuclear power plant, seismic performance may be reduced by reflecting the characteristics of domestic seismic motions. The failure modes of the equipment are typically structural failure and functional failure, with an anchorage failure being a representative type of structural failure. In this study, comparative analyses were performed to decide whether to consider the inelastic behavior of the anchorage or not. As a result, it was confirmed that the seismic performance of the anchorages could be increased by considering the inelastic behavior of an anchorage.

Microwave Radiation-Assisted Chitin Deacetylation: Optimization by Response Surface Methodology (RSM)

  • Iqmal Tahir;Karna Wijaya;Mudasir;Dita Krismayanti;Aldino Javier Saviola;Roswanira Abdul Wahab;Amalia Kurnia Amin;Wahyu Dita Saputri;Remi Ayu Pratika
    • Korean Journal of Materials Research
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2024
  • The optimization of deacetylation process parameters for producing chitosan from isolated chitin shrimp shell waste was investigated using response surface methodology with central composite design (RSM-CCD). Three independent variables viz, NaOH concentration (X1), radiation power (X2), and reaction time (X3) were examined to determine their respective effects on the degree of deacetylation (DD). The DD of chitosan was also calculated using the baseline approach of the Fourier Transform Infrared (FTIR) spectra of the yields. RSM-CCD analysis showed that the optimal chitosan DD value of 96.45 % was obtained at an optimized condition of 63.41 % (w/v) NaOH concentration, 227.28 W radiation power, and 3.34 min deacetylation reaction. The DD was strongly controlled by NaOH concentration, irradiation power, and reaction duration. The coefficients of correlation were 0.257, 0.680, and 0.390, respectively. Because the procedure used microwave radiation absorption, radiation power had a substantial correlation of 0.600~0.800 compared to the two low variables, which were 0.200~0.400. This independently predicted robust quadratic model interaction has been validated for predicting the DD of chitin.

The Study of DEP Degradation Properties by Combination US and UV Lamp of Different Wavelength (초음파 (US)와 다양한 파장범위의 자외선 (UV) 조사에 따른 DEP 분해특성에 관한 연구)

  • Na, Seung-Min;Cai, Jinhua;Shin, Dong-Hoon;Cui, Mingcan;Khim, Jee-Hyeong
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.845-853
    • /
    • 2012
  • Diethyl phthalate (DEP) is widely spread in the natural environment as an endocrine disruption chemicals (EDs). Therefore, in this study, ultrasound (US) and ultraviolet (UVC), including various applied power density (10-40 W/L), UV wavelengths (365 nm, 254 nm and 185 nm) and frequencies (283 kHz, 935 kHz) were applied to a DEP contaminated solution. The pseudo-first order degradation rate constants were in the order of $10^{-1}$ to $10^{-4}\;min^{-1}$ depending on the processes. Photolytic and sonophotolytic DEP degradation rate also were high at shortest UV wavelength (VUV) due to the higher energy of photons, higher molar absorption coefficient of DEP and increased hydroxyl radical generation from homolysis of water. Sonolytic DEP degradation rate increased with increase of applied input power and the dominant reaction mechanism of DEP in sonolysis was estimated as hydroxyl radical reaction by the addition of t-BuOH, which is a common hydroxyl radical scavenger. Moreover, synergistic effect of were also observed for sonophotolytic degradation with various UV irradiation.

Cladding of Cu and Bronze/Al Alloy by $CO_2$ Laser (고출력 $CO_2$레이저빔에 의한 구리, 청동/알루미늄 합금 클래딩)

  • 강영주;김재도
    • Journal of Welding and Joining
    • /
    • v.15 no.4
    • /
    • pp.109-115
    • /
    • 1997
  • Laser cladding is a technique for modification of metal surface. In this laser cladding experiment a metal powder feeding system was developed for more efficient laser cladding. This system can reduce processing time and be used simpler than the conventional method. The feeding of metal powder has given a rise to the process for sequential buildup of bulk rapidly solidified materials in the form of fine powder stream to the laser cladding process. The parameters of laser cladding have been investigated using this experimental equipment. Bronze on aluminum alloy and copper on aluminum alloy were experimented by using defocused beam, powder feeding system, and gas shielding. Good cladding was achieved in the range of beam travel speed of 2.25m/min. In the case of copper/aluminum and bronze/aluminum substrate, the absorption of laser beam was too high to produce low diluted clad. In the case of copper/1050 aluminum, the optimal laser cladding condition was of laser power of 2.8kW, powder feed rate of 0.31g/s and beam travel speed of 2.25m/min. In the case of bronze/aluminum the optimal condition is of laser power of 2.5kW, powder feed rate of 0.31g/s, and beam travel speed of 2.36m/min.

  • PDF

Failure Analysis and Weibull Statistical Analysis according to Impact Test of the Angular Pin for Injection Molding Machines (사출금형기계용 앵귤러핀의 충격시험에 따른 파손분석과 와이블 통계 해석)

  • Kim, Cheol-Su;Nam, Ki-Woo;Ahn, Seok-Hwan
    • Journal of Power System Engineering
    • /
    • v.21 no.3
    • /
    • pp.37-44
    • /
    • 2017
  • In this study, failure analysis of the angular pin for molding machines to aluminum component molding was carried out. SM45C steel was used for the angular pin, it was surface hardened by the induction surface hardening heat treatment. The cross section of damaged angular pin was observed, and micro Vickers hardness value from the fractured part was measured. Brittle fracture was occurred from the fracture surface of angular pin, therefore, impact toughness value was evaluated by V-notch Charpy impact test. It was confirmed that the impact absorption energy was high when was tempered at a high temperature for a long time, and the toughness was slightly increased. Also, 2-parameter Weibull statistical analysis was investigated in order to evaluate the reliability of the measured micro Vickers hardness values and absorbed energy. The micro Vickers hardness and absorbed energy well followed a two-parameter Weibull probability distribution, respectively. The reverse design against angular pin was proposed as possible by using test results.

UV Sensor using Evanescent Field Coupling of Prism and Fiber-to-Planar Waveguide Coupler (프리즘과 광섬유-평면도파로의 소산장 결합을 이용한 자외선 센서)

  • Cho, Kang-Min;Yun, Jung-Hyun;Kim, Eung-Soo;Lee, Seung-Ha;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.350-355
    • /
    • 2004
  • A novel UV sensor was manufactured and characterized using the evanescentfield coupling between fiber-planar waveguide (PWG) coupler and prism. A spiroxazine dye was chosen as planar waveguide because its photochromic isomerization induced by UV irradiation. A novel UV sensor was proposed to measure the variation of refractive index and absorption coefficient simultaneously. The wavelength responses of these sensors by UV exposure times were measured 0.48 nm/sec, 0.757 nm/sec, and ATR output power variations were measured $-0.424{\mu}W$/sec and $-0.62{\mu}W$/sec when UV exposure power were 3 mW and 5 mW, respectively.

Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings (마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF