• 제목/요약/키워드: Absorption power

검색결과 849건 처리시간 0.032초

설정 음압 및 스펙트럼 재현을 위한 음향 환경 시험 챔버의 기본 설계 변수 선정 (Design of High Intensity Acoustic Test Facility to Generate Required Sound Pressure Level and Spectrum)

  • 김영기;우성현;김홍배;문상무;이상설
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.867-872
    • /
    • 2002
  • A high intensity acoustic test facility is constructed at Korea Aerospace Research Institute (KARI) by 2003. The reverberant chamber of the facility has a volume of 1,228 cubic meters and shall provide an acoustic environment of 152 dB over the frequency range of 25 Hz to 10,000 Hz. The facility consists of a large scaled reverberant chamber, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of a chamber and power generation systems are controlled to meet the requirement of the test. The volume of a reverberant chamber is controlled by the size of test objects and the reverberant characteristics of a chamber. The capacity of acoustic power generation systems is determined by the energy absorption of a chamber and the efficiency of acoustic modulators. Simple math is employed to calculate the required power of acoustic modulators. Moreover, the paper explains how the distribution of sound pressure level at low frequency is checked by analytical and numerical methods.

  • PDF

콘크리트 구조물에서의 열전모듈 거동에 관한 기초연구 (Fundamental Study of the Behavior of Thermoelectric Module on Concrete Structure)

  • 임치수;이재준
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.33-38
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to investigate the application of thermoelectric technology to concrete structures for harvesting solar energy that would otherwise be wasted. In various fields of research, thermoelectric technology using a thermoelectric module is being investigated for utilizing solar energy. METHODS: In our experiment, a halogen lamp was used to produce heat energy instead of the solar heat. A data logger was used to record the generated voltage over time from the thermoelectric module mounted on a concrete specimen. In order to increase the efficiency of energy harvesting, various factors such as color, architecture, and the ability to prevent heat absorption by the concrete surface were investigated for the placement of the thermoelectric module. RESULTS : The thermoelectric module produced a voltage using the temperature difference between the lower and upper sides of the module. When the concrete specimen was coated with an aluminum foil, a high electric power was measured. In addition, for the power generated at low temperatures, it was confirmed that the voltage was generated steadily. CONCLUSIONS: Thermoelectric technology for energy harvesting can be applied to concrete structures for generating electric power. The generated electricity can be used to power sensors used in structure monitoring in the future.

PCM을 적용한 자연대류형 수냉식 방열기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of the Liquid Cooling Radiator of the Natural Convection Type by Using the PCM)

  • 성대훈;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.324-329
    • /
    • 2008
  • The liquid cooling effect of a natural convection type radiator by using the PCM has been investigated experimentally. The radiator size is $423{\times}295{\times}83$ mm and PCM container size is $398{\times}270{\times}26$ mm. The objective is elapsed time higher than maximum time to reach for maximum operating temperature of a general liquid cooling radiator. This study, in order to study on the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, ambient and melting point of three type PCM. For the above experimental parameter, the melting time was performed about 180/250/560 min at input power 150 W and ambient $30^{\circ}C$ from using the three type PCM(PCM_S1/S2/S3) respectively. Furthermore, the effects of the thermal dissipation was decreased higher input power than lower input power at heating block and melting time of PCM. However, the effects of mass flow rate did not nearly affect of the thermal performance especially.

  • PDF

연소 후 $CO_{2}$ 포집공정이 적용된 500MWe 석탄화력발전소의 성능 및 경제성평가 (Performance and Economic Analysis of 500 MWe Coal-Fired Power Plant with Post-Combustion $CO_{2}$ Capture Process)

  • 이지현;김준한;이인영;장경룡;심재구
    • Korean Chemical Engineering Research
    • /
    • 제49권2호
    • /
    • pp.244-249
    • /
    • 2011
  • 연소 후 $CO_{2}$ 포집기술이 적용된 500 MWe 석탄화력발전소의 경제성평가를 수행하고 $CO_{2}$ 저감비용(Cost of $CO_{2}$ avoided)을 산출하였다. 본 연구에서 고려된 $CO_{2}$ 포집기술은 이미 상업적으로 적용이 가능하고, 기존의 화력발전에 적용이 용이한 화학 흡수법을 기초로 하였으며 투자비용 산출을 위해 IEA Greenhouse Gas R&D Programme에서 제시하는 데이터를 활용하였다. 또한 $CO_{2}$ 포집공정 중 가장 많은 발전효율 저하를 가져오는 재열기(리보일러)에 투입되는 열에너지(재생에너지)를 대상으로 민감도분석을 수행하고 각각의 경우에서의 $CO_{2}$ 저감비용을 산출하였다. 분석결과 $CO_{2}$ 포집공정에 적용될 흡수제로 MEA(모노에탄올아민)가 사용되고 재생탑에서 필요한 재생에너지가 3.31 GJ/ton$CO_{2}$ 인 경우 발전효율은 $CO_{2}$ 포집설비 설치 전의 41.0에서 31.6%로 9.4% 감소하고 이때의 $CO_{2}$ 저감비용은 43.3 $/ton$CO_{2}$ 로 산출되었다. 그러나, 흡수제 재생에너지를 변수로 한 민감도분석에서 재생에너지가 2.0 GJ/ton$CO_{2}$로 낮아질 경우 $CO_{2}$ 저감비용은 36.7 $/ton$CO_{2}$까지 낮아질 것으로 분석되었다.

방전에 의한 프라즈마에서의 마이크로파 전파특성 (The Properties of Microwave Propagation in Discharging Plasma)

  • 양인응;노방현;김봉열
    • 대한전자공학회논문지
    • /
    • 제5권3호
    • /
    • pp.31-39
    • /
    • 1968
  • 외부자계가 가해진 냉프라즈마에서의 마이크로파 전파 특성을 측정하였다. 직류방전프라즈마는 두 전극판을 구형도파관에 삽입한것과, 또한 유리시설관을 구형도파관에 삽입한 것에서 이루어졌다. 마이크로파 전파방향, 방전관축, 외부자계는 각각 수직이고, 자속밀도, 방전유기, 기체압등이 증가할때 프라즈마를 전파하는 마이크로파의 감쇠 및 흡수는 증가함을 보았다.

  • PDF

Characterization of Ultra Low-k SiOC(H) Film Deposited by Plasma-Enhanced Chemical Vapor Deposition (PECVD)

  • Kim, Sang-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권2호
    • /
    • pp.69-72
    • /
    • 2012
  • In this study, deposition of low-dielectric constant SiOC(H) films by conventional plasma-enhanced chemical vapor deposition (PECVD) were investigated through various characterization techniques. The results show that, with an increase in the plasma power density, the relative dielectric constant (k) of the deposited films decreases whereas the refractive index increases. This is mainly due to the incorporation of organic molecules with $CH_3$ group into the Si-O-Si cage structure. It is as confirmed by FT-IR measurements in which the absorption peak at 1,129 $cm^{-1}$ corresponding to Si-O-Si cage structure increases with power plasma density. Electrical characterization reveals that even after fast thermal annealing process, the leakage current density of the deposited films is in the order of $10^{-11}$ A/cm at 1.5 MV/cm. The reliability of the SiOC(H) film is also further characterized by using BTS test.

Optically Detected Magnetic Resonance with Nitrogen-Vacancy Spin Ensemble in Diamond

  • Lee, Hyun Joon;Shim, Jeong Hyun
    • 한국자기공명학회논문지
    • /
    • 제22권2호
    • /
    • pp.40-45
    • /
    • 2018
  • We report Optically-Detected Magnetic Resonance (ODMR) study on Nitrogen-Vacancy (NV) centers in diamond. The experiment can easily be conducted with basic optics and microwave components. A diamond crystal having a high-density NV center is suitable for the ODMR study. The magnetic field dependence of ODMR spectrum allowed us to determine the orientation of the diamond crystal. In addition, we measured the variation of the ODMR spectrum as a function of the excitation laser power. Thermal heating induced by optical absorption caused the monotonic decrease of zero field splitting. The contrast of the ODMR peak, however, increased and, then, began to decrease, indicating the optimal laser power for recording the ODMR spectrum.

소형 승용차량의 SEA 모델링 및 내부 소음 연구 (A SEA Modeling of a compact car and Interior Noise Analysis)

  • 김상수;김관주;임효석;김영호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.824-828
    • /
    • 2007
  • In this paper Statistical Energy Analysis has been considered to predict middle, high frequency air borne interior noise. PIM method is used for verification. Damping loss factor and coupling loss factor have been derived from the response(SPL) of sub systems when the power is applied. The airborne SEA model of vehicle is modeled through AutoSea2. Insulation material's absorption coefficient and transmission loss are acquired from closed form solution and experiment.

  • PDF

FDTD를 이용한 인체 두부모델의 SAR 분포특성 해석 (Analysis of SAR Distribution Characteristics in a Head Model using FDTD)

  • 홍동욱;김두현;강동규
    • 한국안전학회지
    • /
    • 제19권2호
    • /
    • pp.34-40
    • /
    • 2004
  • This paper presents an analysis of SAR(Specific Absorption Rate) distribution characteristics in a head model using FDTD(Finite Difference Time Domain). In this study human head was modelled in four elements-layered structure, consisting of skin, fat, skull and brain. To calculate the electromagnetic fields wihtin the head model, FDTD method was used. In the FDTD method, the electromagnetic wave is analyzed by solving a Maxwell's equations repeatedly. For the calculation, distance between power source and head model increased by 10[m]. Power density and incident electric field intensity were calculated. Based on the incident electric field, the program which calaculated internal electric fields intensity and SAR calculation of the head model were developed. The results of developed program using FDTD were compared with those of a commericial programs, which showed the availability and usefulness of the suggested scheme in this paper.

방사선투과영상의 기하학적 왜곡 보정에 관한 연구 (The Study on image correction of geometric distortion in digital radiography image)

  • 박상기;안연식;길두송
    • 동력기계공학회지
    • /
    • 제15권4호
    • /
    • pp.25-30
    • /
    • 2011
  • This study is made to provide with a method for correcting the geometric distortion of the digital radiography image by analytical approach based upon the inverse square law and Beer's law. This study is aimed to find out and improve a mathematic model of nonlinear type. Variations in the alignment of the X-ray source, the object, and imaging plate affect digital radiography images. A model which is expressed in parameter values; e.g, angle, position, absorption coefficient, length, width and pixel account of radiography source, is developed so as to match the sample image. For the best correction of the digital image that is the most similar to the model image, a correction technique based upon tangent is developed; then applied to the digital radiography images of steel tubes. As a result, the image correction is confirmed to be made successfully.