• 제목/요약/키워드: Absorption chiller$NH_3/H_2O$

검색결과 5건 처리시간 0.018초

태양열 구동 $NH_3/H_2O$ 흡수식 냉동기 리모델링 연구 (A Study on Remodeling for Solar driven $NH_3/H_2O$ absorption chiller)

  • 신유수;맹주성;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.37-43
    • /
    • 2003
  • The aim of this research is to study the feasibility of the solar(hot fluid) driven $NH_3/H_2O$ absorption chiller, made by re-manufacturing of Gas fired $NH_3/H_2O$ absorption chiller. This experimental study is performed with the temperature of the inlet hot fluid of generator. In order to determine the inlet temperature of the generator, which gives maximum COP, the experimental data are obtained with various hot fluid supply temperature in range of $130\sim170^{\circ}C$. Remodeled chiller is operated with periodical cooling effect, which due to mixture subcooled pool boiling, then the COP is evaluated in average. The maximum COP$(\sim0.36)$ is at $160^{\circ}C$. The temperature is stable operation temperature range of typical vacuum collector. It offers a feasibility of solar driven $NH_3/H_2O$ absorption chiller.

5 RT 공랭형 $NH_3-H_2O$ 흡수식 냉동기의 발생기 입력 열량과 외기온도 변화에 따른 성능분석 (Performance Analysis of a 5 RT Air-Cooled $NH_3-H_2O$ Absorption Chiller with the Variations of Heat Input and Ambient Temperature)

  • 윤희정;김성수;강용태
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.438-443
    • /
    • 2004
  • The objective of this paper is to study the effects of the input gas flow rate and the ambient temperature variation on the absorption cycle performance. An air-cooled NH$_3$-$H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect maching is 17.6 ㎾ (5.0 USRT). The cooling capacity, coefficient of performance, burner efficiency, and each state point are measured with the variations of the heat input and the ambient temperature. It is found that the COP and cooling capacity increase with increasing the generator exit temperature up to a certain temperature and then decrease. It is also found that the COP and the cooling capacity decrease with increasing the ambient temperature. The maximum COP of 0.51 is obtained from the present experiment.

공랭형 $NH_3/H_2O$ 흡수식 냉동기의 모사 및 실험적 연구 (Simulation and Experimental Study on an Air-Cooled $NH_3/H_2O$ Absorption Chiller)

  • 오민규;김현준;김성수;강용태
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1028-1034
    • /
    • 2005
  • The objective of this paper is to study the effects of the cooling air mass flow rate and the heat input variation by the simulation and the experiment. An air-cooled $NH_3/H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect machine is 17.6 kW (5.0 USRT). The overall conductance (UA) of each component, the cooling capacity, coefficient of performance and each state point are measured with the variation of the cooling air mass flow rate and the heat input. It is found that the COP and cooling capacity increase and then decreases with increasing the heat input. It is also found that the COP and the cooling capacity increase and keep constant with increasing the cooling air mass flow rate. The maximum COP is estimated as 0.51 and the optimum cooling air mass flow rate is $217\;m^3/min$ from the present experiment.

7RT급 암모니아 흡수식 냉온수기의 냉방성능 특성 (The Characteristics of Cooling Performance on 7RT Ammonia Absorption System)

  • 이호생;진병주;윤정인;황준현;진심원;경익수
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.433-438
    • /
    • 2009
  • Experimental results for performance characteristics of small $NH_3$ absorption chiller/ heater are presented. The apparatus consists of 7RT water-cooled absorption system, solution pump, boiler, cooling tower and peripheral devices. The effect of experimental parameters, such as refrigerant mass flow rate, solution mass flow rate and cooling water temperature have been investigated in view of the system performance. The capacity of each heat exchanger increased as refrigerant mass flow rate increased in cooling mode. Also, a cooling capacity increased as a strong solution mass flow rate increased. The cooling and heating COP show 0.5, 1.5 regardless of refrigerant mass flow rate, respectively. The results focus on the evaluation for performance characteristics of system with respect to variation of refrigerant mass flow rate under standard design conditions.