• 제목/요약/키워드: Absorption air condition

검색결과 118건 처리시간 0.028초

Effects of Air-Dried Leaves of Evergreen Broad-Leaved Trees on Sound Absorption Property

  • JUNG, Su-Young;KONG, Ree-Keun;LEE, Kwang-Soo;BYEON, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권5호
    • /
    • pp.482-490
    • /
    • 2021
  • This research was conducted to analyze the sound absorption effect of air-dried leaves from two evergreen tree species found in Korea's warm-temperate and subtropical regions. As eco-friendly sound absorption materials, Dendropanax morbiferusa, and Fatsia japonica leaves were prepared in three specimen units sizes 0.5 × 0.5 cm2, 1.0 × 1.0 cm2, and 2.0 × 2.0 cm2, and each of them was formed at a thickness of 1.00 cm, 1.75 cm, and 2.50 cm. The measured sound absorption coefficients (SAC) for 18 conditions were comparatively analyzed in this study. The SAC of both tree species was significantly improved by increasing the dried leaf layer thickness. These results showed a more consistent and distinct trend for both tree species under the condition of 0.5 cm2 in dried leaf size compared to other leaf specimen sizes. However, as the thickness increased, the difference in sound absorption effect according to the leaf size tends to decrease overall. In the case of D. morbiferus, there was no significant difference in SAC based on leaf size under the condition of 2.5 cm thickness (p < 0.05). The highest mean SAC was found in a 2.5 cm thick condition with a leaf size of 0.5 × 0.5 cm2, 0.549 for D. morbiferusa, and 0.594 for F. japonica, respectively.

증기흡수시(蒸氣吸收時) 계면활성제액적간(界面活性劑液滴間)에 발생(發生)하는 마랑고니대류거동(對流擧動)의 가시화(可視化) (Visualization of Marangoni Convection Behavior between Two Surfactant Dropwises in the Process of Steam Absorption)

  • 이동호;최국광;백목효부;서정윤
    • 설비공학논문집
    • /
    • 제4권2호
    • /
    • pp.65-71
    • /
    • 1992
  • In most absorption machines, absorption enhancement has been achieved by adding small amount of surfactant additive, which introduced the surface tension difference between absorbent and surfactant droplets in the vapor absorption. The aim of this study is to understand a basic mechanism of Marangoni convection and its effectiveness in the vapor absorption enhancement. In this study, nonflowing aqueous solution of LiBr 60 mass% was exposed to saturated water vapor under the condition that two dropwises surfactant were fixed on the absorbent surface. Our experiments achieved to visualize the enhanced heat and mass transfer phenomena by the effect of Marangoni convection through the laser holographic interferometry. Also, Marangoni convection behavior was obtained by using tracer method.

  • PDF

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향 (Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator)

  • 김선창;김영률;백종현;박승상
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.

Thermal and Absorbing Performance in a Vertical Absorber

  • Cho, Keum-Nam;Kim, Jung-Kuk
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.51-59
    • /
    • 2000
  • The purpose of the present study is to investigate the absorbing characteristics in a vertical falling film type absorber using LiBr-H$H_2O$ solution as working fluids with the concentration of 60 wt%. The experimental apparatus consists of an absorber with the diameter of 17.2 mm and the length of 1150 mm, a generator, an evaporator (condenser), a weak solution tank and a sampling trap device and so on. The parameters were the solution temperatures of 45 and 50$^{\circ}$C, coolant temperatures of 30 and 35$^{\circ}$C, and the film Reynolds numbers from 50 to 150. The pressure drop in the absorber increased as the solution and coolant temperatures decreased. The pressure drop in the absorber increased up to the film Reynolds number of 90, however, decreased at the film Reynolds number above 90. The maximum absorption mass flux was observed at the film Reynolds number of 90. Absorption mass fluxes increased as the coolant temperature decreased. Accordingly, absorption mass fluxes and heat transfer coefficients under the subcooled condition increased more than those under the superheated condition. It is claimed that heat transfer coefficients are deeply affected by the solution temperature more than the coolant temperature within the experimental range.

  • PDF

항공교통관제사의 감정통제가 직무몰입과 조직충성도에 미치는 영향 (An Effect of Air Traffic Controllers' Emotional Regulation to Their Job Involvement and Organizational Loyalty)

  • 김상수;김기웅;최진영;이명우;최연철
    • 한국항공운항학회지
    • /
    • 제24권4호
    • /
    • pp.53-61
    • /
    • 2016
  • Air Traffic Controllers (ATC) are also essential to the efficiency of airports and the airline industry. With the increasing volume of traffic, managing flights is a complex and sometimes very stressful job. ATC is using radar and other technology to track planes 'en route' between airports and keep in touch with pilots. Alternatively, ATCs are liaising with the planes on approach. However, ATC's working condition is getting more stressful, as the volume of air traffic increases. Thus this paper tried to research cognitive emotional regulation, job satisfaction, and job involvement and organizational committment of ATCs under the stressful work condition, taking care of safety of a couple of hundreds passengers per plane. Using CERQ survey sheet (Cognitive Emotional Regulation Questionnaire), it was found out that positive thinking and acceptance of self-blame have a significant impact on job satisfaction, work absorption and organizational Loyalty.

진공중에서의 알루미나 세라믹스의 Tribology 특성

  • 진동규;이충엽;전태옥;박홍식
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.66-75
    • /
    • 1997
  • This study was undertaken to investigate tribology characteristics of the alumina ceramics($Al_2O_3$) of the various purity for the variation of ambient condition such as air and vacuum. The wear test was carried out under different experimental condition using the wear test device, which was designed for this study, and in which the annular surface of wear testing specimens as well as mate specimen made of STB2 steel, were subjected to sliding speed, applied load and the sliding distance. The results obtained were as follows. As the ambient pressure decreases, the friction coefficient increases because the protective layer made of absorption due to decrease of the amount of ambient gas can not be formed. As the friction coefficient paticularly for 85% alumina lower than 95% and 99.7% in the alumina purity increases by an influence of heat accumulation caused by small elastic modulus and thermal conductivity. The friction surface of ceramics can be protected in the air by the influence of the oxides transfered from STB2. However, in the vacuum, the protective layer made of the absorption substance can not be formed due to the decrease of ambient gas.

  • PDF

침지처리법에(浸漬處理法)있어서 목재함수량(木材含水量)이 염화아연 흡수율(吸收率)에 미치는 영향(影響) (A Study on the Effect of Moisture Content of Wood upon the Absorption on Zinc Chloride Solution)

  • 심종섭;신동소
    • Journal of the Korean Wood Science and Technology
    • /
    • 제10권3호
    • /
    • pp.133-134
    • /
    • 1982
  • This experiment has been made to investigate the absorption of watersoluble zinc chloride by Pinus densiflora S. et Z. at different moisture content, under soaking process, to decide the optimum content condition for the maximum absorption of zinc chloride by the wood tested and to investigate the concentration of zinc chloride affecting each moisture content of wood. Material was cut in the Dept. of Forest, College of Agr. S.N.U. Suwon, Korea. Sample was divided into sap and heartwood group and cut $2{\times}2{\times}2\;cm$ in size, having exact three dimensions, using the part of D.B.H. The numbers of sample were 20 pieces for each moisture content condition for both sap and heartwood. Especially, the samples were protected from exposure to keep moisture content in green condition. The ranges of moisture content tested were as the table 3 and 4. The conclusions were as follows: 1. With 3% zinc chloride solution, the rate of absorption decreased with the time increased, if the air seasoned Korean red pine (Pinus densiflora S. et Z.) was treated in steeping process. Initial absorption for 30 minutes was more than 50% of total absorpon for 24 hours. 2. Rate of absorption was same under the green condition, while rate of absorption under the moisture content 7 to 30% varied. 3. Although it was not quite proportional change in the absorption with the difference of moisture content, the great change in the absorption occured by seasoning. With exception sap green condition, sapwood twice more permeable than the heartwood in the oven dried condition and it has been observed the nearly same amount of absorption at the moisture content of 7%, 10% and 15% respectively in heartwood. 4. It was better from water in wood from view-point of absorption of zinc chloride solution, but it was difficult practically to obtain the smallest moisture content, and then it was decided that values of allowable moisture content, on the basis of mean absorption, were 15% to 20% in the sapwood, and in the heartwood, 10% to 15%. The mean absorption for each moisture content in the sap and the heartwood were as following. 5. In general, the concentration of zinc chloride after steeping was nearly same between moisture content and sap and heartwood respectively.

  • PDF

리튬브로마이드 수용액 유하액막의 흡수과정에 대한 근사 해법 : 증기 유동의 영향 (Approximate solutions on the absorption process of an aqueous LiBr falling film : effects of vapor flow)

  • 김병주;이찬우
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.144-152
    • /
    • 1997
  • Film absorption involves simultaneous heat and mass transfer in the vapor-liquid system. In the present work, the absorption process of water vapor by an aqueous soluton of LiBr flowing inside of the vertical tube was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the heat and mass transfer rate. Particularly the effects of vapor flow conditions on the absorption process were investigated in terms of the vapor Reynolds number. As the vapor Reynolds number increased, the shear stress at the vapor-solution interface also increased. Consequently solution film became thinner at higher vapor flowrate under the co-currentflow condition. Thinner film was capable of higher heat transfer to the wall and leaded to higher absorption rate of the water vapor into the solution film.

  • PDF

원자흡수분광법에 의한 다원소 동시분석시 조건의 최적화 (Optimization of Parameters for Simultaneous Multielemental Analysis by Atomic Absorption Spectrometry)

  • 김효진;강종성
    • 분석과학
    • /
    • 제6권4호
    • /
    • pp.359-362
    • /
    • 1993
  • 원자흡수분광법으로 여러 원소를 동시분석시 최적 조건을 위하여 연료의 종류, 연료의 양 및 버너 높이의 변화에 대해 10가지 원소의 흡광도를 측정하였다. Air-$C_2H_2$를 연료로 과량을 사용하고, 버너 높이가 2mm일 때 최적 흡광도를 나타내었고, 이때 10가지 원소의 상대흡광도의 평균은 73%였다.

  • PDF