• Title/Summary/Keyword: Absorption Mass Transfer Rate

Search Result 85, Processing Time 0.025 seconds

Study on the Prediction of Absorption Performance by the Optimization of a Vertical Absorber (수직형 흡수기 최적화에 따른 흡수 성능 예측에 관한 연구)

  • Kim, Jung-Kuk;Cho, Keum-Nam
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.194-202
    • /
    • 2005
  • The present study was analytically and experimentally carried out to predict the absorption characteristics on combined heat and mass transfer process in a vertical falling film of variable absorbers. Heat and mass transfer enhancements were analytically investigated. Effects of geometric parameters by insert device (spring) and corrugate, flow pattern on absorption performances has been also investigated. Especially, the optimal values of absorber geometry (ID=22.8mm, L=1150m) and kinetic variables (solution flow rate, flow pattern) for maximum absorption performance has been predicted by the numerical analysis. The maximum absorption performance in a numerical analysis and experiment was shown at the wavy-flow by insert device (spring).

An Experimental Study on Falling Film Heat and Mass Transfer for Binary Nanofluids ($H_2O$/LiBr+Nanoparticles) (이성분 나노유체($H_2O$/LiBr+나노입자)를 적용한 유하박막 흡수기의 열 및 물질전달 촉진 실험)

  • Kim, Hyun-Dae;Kim, Sung-Su;Nam, Sang-Chul;Jeong, Jin-Hee;Kang, Yong-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.130-135
    • /
    • 2008
  • The objectives of this study are to investigate the combined heat and mass transfer enhancement using binary nanofluids as the working fluids in a $H_2O$/LiBr absorber. The result of heat and mass transfer experiment with the additives(Arabicgum, 2E1H) showed that the heat and mass transfer performance of binary nanofluid with 2E1H enhanced significantly in comparison with that without additive. In the case of 0.01wt% $Al_2O_3$ binary nanofluids with 2E1H, the vapor absorption rate increased up to 77% in comparison with that without additive. The heat transfer rate of 0.01wt% $Al_2O_3$ binary nanofluids with 2E1H increased up to 19%. Based on the experimental results, it is recommended that the $Al_2O_3$ binary nanofluid be good with 2E1H to improve the heat and mass transfer performance.

  • PDF

Effect of degree of superheat of LiBr aqueous solution on the vapor absorption process for an air-cooled absorption cooling system (공냉형 흡수식 냉방 시스템에서 LiBr 수용액의 과열도가 증기 흡수에 미치는 영향)

  • Kim, S.C.;Oh, M.D.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-133
    • /
    • 1997
  • Numerical analysis using finite volume method has been carried out to examine the effect of degree of superheat of LiBr aqueous solution on heat and mass transfer occurred in absorption process. According to the result of this study, it was found that refrigerant vaper was generated at the entrance region of absorber when LiBr aqueous soltion was superheated. As the degree of superheat increases, heat transfer rate increases and vapor absorption rate decreases. The increase in averaged Nusselt and Sherwood numbers could be found as film Reynolds number increases. The larger the degree of superheat, the greater the averaged Nusselt and Sherwood numbers.

  • PDF

Mass transfer in adiabatic rectifier of ammonia-water absorption system (암모니아-물 흡수식 시스템에서 단열정류기의 물질 전달)

  • 김병주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.414-421
    • /
    • 1999
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and liquid interface. In the present work, the adiabatic rectification process of ammonia-water vapor on the vertical plate was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer in each phases were investigated. The stripping of water in vapor mixture occurred new the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer in falling film.

  • PDF

Mass Transfer in an Adiabatic Rectifier of Ammonia-Water Absorption System

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.69-79
    • /
    • 2000
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and solution film. In the present work, the adiabatic rectification process of ammonia-water vapor by the falling solution film on the vertical plate was investigated. The continuity momentum, energy and diffusion equations for the solution film and the vapor mixture were formulated in integral forms and solved numerically, The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer coefficient in each phases were investigated. The stripping of water in vapor mixture occurred near the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer coefficient in falling film.

  • PDF

Development of a Novel Bioreactor System for the Treatment of Gaseous Benzene

  • Yeom, Sung-Ho;Daugulis, Andrew J.;Yoo, Young-Je
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.73-76
    • /
    • 2000
  • A novel, continuous bioreactor system combining a bubble column (absorption section) and a two-phase bioreactor (degradation section) has been designed to treat a gas stream containing benzene. The bubble column contained hexadecane as an absorbent for benzene, and was systemically chosen considering physical, biological, environmental, operational and economic factors. This solvent has infinite solubility for benzene and very low volatility. After absorbing benzene in the bubble column, the hexadecane served as the organic phase of the two-phase partitioning bioreactor, transferring benzene into the aqueous phase where it was degraded by Alcaligenes xylosoxidans Y234. The hexadecane was then continuously recirculated back to the absorber section for the removal of additional benzene. All mass transfer and biodegradation characteristics in this system were investigated prior to operation of the integrated unit, and these included: the mass transfer rate of benzene in the absorption column, the mass transfer rate of benzene from the organic phase into the aqueous phase in the two-phase bioreactor, the stripping rate of benzene out of the two-phase bioreactor, etc. All of these parameters were incorporated into model equations, which were used to investigate the effects of operating conditions on the performance of the system. Several experiments were conducted to show the feasibility of this system. This process is believed to be very practical for the treatment of high concentrations of gaseous pollutants.

  • PDF

Effect of elasticity of aqueous xanthan gum solution with 2-amino-methyl-1-propanol on chemical absorption of carbon dioxide

  • Park, Sang-Wook;Choi, Byoung-Sik;Song, Ki-Won;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Absorption rate of carbon dioxide was measured in the aqueous xanthan gum (XG) solution in the range of 0-0.15 wt% containing 2-amino-2-methyl-1-propanol (AMP) of $0-2\;kmol/m^3$ in a flat-stirred vessel with an impeller of 0.05m and agitation speed of 50rpm at $25^{\circ}C$ and 0.101 MPa. The volumetric liquid-side mass transfer coefficient ($k_La$) of $CO_2$, which was correlated with the viscosity and the elastic behavior of XG solution containing Deborah number as an empirical formula, was used to estimate the chemical absorption rate of $CO_2\;(R_A)$. $R_A$, which was estimated by mass transfer mechanism based on the film theory using the physicochemical properties and the kinetics of reaction between $CO_2$ and AMP, was compared with the measured rate. The aqueous XG solution with elastic property of non-Newtonian liquid made $R_A$ increased compared with Newtonian liquid based on the same viscosity of the solution.

Chemical Absorption of Carbon Dioxide into Non-Newtonian Polyacrylamide Solution (Polyacrylamide 비뉴튼액체에서의 이산화탄소의 화학흡수)

  • Hwang, Byung-Jin;Park, Sang-Wook
    • Clean Technology
    • /
    • v.14 no.4
    • /
    • pp.281-286
    • /
    • 2008
  • Absorption rate of carbon dioxide was measured in the aqueous polyacrylamide (PAA) solution containing triethanolamine (TEA) of $0{\sim}2.0\;kg\;mol/m^3$ in a flat-stirred vessel with an impeller of 0.05 m and agitation speed of 50 rpm at $25^{\circ}C$ and 101.3 kPa. The chemical absorption rate of $CO_2$ was estimated by mass transfer mechanism based on the film theory using the physicochemical properties containing the liquid-side mass transfer coefficient of $CO_2$ and the kinetics of reaction between $CO_2$ and TEA to compare with the measured rate. The aqueous PAA solution acted as a reducing agent by viscoelastic property of non-Newtonian liquid based on the same viscosity of the solution.

  • PDF

Performance Analysis of Micro-turbine CHP System with Absorption Chiller (흡수식 칠러를 장착한 마이크로터빈 구동 열병합시스템의 성능 해석)

  • Yun, Rin;Han, Seung-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.540-545
    • /
    • 2007
  • The performance of microturbine CHP system equipped with an absorption chiller was analyzed by modelling of a microturbine and an absorption chiller. The microturbine having recuperator was simulated by the Brayton cycle model. The mass flow rate and available heat energy of the exhaust gas from the microtubune were simulated, and this results were utilized as input values for the generator of the absorption chiller. The absorption chiller is a single-effect air cooled type having solution heat exchanger. When heat input to the generator increased, the heat transfer rate and UA of the heat exchangers of the absorption chiller proportionally increased. Besides, the COP of the absorption chiller increased with increase of the heat input to the generator under the sufficient size of the evaporator condition. When the capacity of the CHP system increased from 30 to 60 kW, the mass flow rate of the LiBr for the absorption chiller increased by two times, and UA values for evaporator and condenser were increased by 3.9 and 3.4 times, respectively, under the same COP condition.

  • PDF

On the Mass Transfer Behaviors in Hollcw-Fiber Membrane Modules for $CO_2$ Separation (이산화탄소 분리를 위한 중공사막 모듈에서의 물질전달 거동)

  • 전명석;김영목;이규호
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.04a
    • /
    • pp.51-52
    • /
    • 1994
  • High permeability, selectivity and stability are the basic properties also required for membrane gas separations. The $CO_2$ separation by liquid membranes has been developed as a new technique to improve the permeability and selectivity of polymeric membranes. Sirkar et al.(1) have atlempted the hollow-fiber contained liquid membrane technique under four different operational modes, and permeation models have been proposed for all modes. Compared to a conventional liquid membrane, the diffusional resistance decreased by the work of Teramoto et al.(2), who referred to a moving liquid membrane. Recently, Shelekhin and Beckman (3) considered the possibility of combining absorption and membrane separation processes in one integrated system called a membrane absorber. Their analysis could be predicted effectively the performance of flat sheet membrane, however, there are restrictions for considering a flow effect. The gas absorption rate is determined by both an interfacial area and a mass transfer coefficient. It can be easily understood that although the mass transfer coefficients in hollow fiber modules are smaller than in conventional contactors, the substantial increase of the interfacial area can result in a more efficient absorber (4). In order to predict a performance in the general system of hollow-fiber membrane absorber, a gas-liquid mass transfor should be investigated inevitably. The influence of liquid velocity on both a mass transfer and a performance will be described, and then compared with experimental results. A present study is attempted to provide the fundamentals for understanding aspects of promising a hollow-fiber membrane absorber.

  • PDF