• 제목/요약/키워드: Absorption Function

검색결과 621건 처리시간 0.032초

CFD 시뮬레이션을 이용한 시설원예단지 여름철 외부 열환경 특성 및 개선방안 (A Characteristics and Improvement of Thermal Environment in Summer of Protected Horticulture Complex Using CFD Simulation)

  • 손진관;공민재;최덕규;강동현;박민정;윤성욱;이승철;이시영
    • 농촌계획
    • /
    • 제24권3호
    • /
    • pp.73-86
    • /
    • 2018
  • Agricultural or rural landscape provides various ecosystem services. However, the ecosystem services function is declining due to various environmental problems such as climate change, land use change, stream intensification, non-point pollution and garbage. The A1B scenario predicts that the mean air temperature of South Korea will rise $3.8^{\circ}C$ degrees celsius in 2100. Agricultural sector is very vulnerable to climate change, so it must be thoroughly predicted and managed. In Korea, the facility horticulture complex is 54,051ha in 2016 and is the 3rd largest in the world(MAFRA, 2014). Facilities of horticultural complexes are reported to cause problems such as groundwater decrease, vegetation and insects diversity reduction, landscapes damage and garbage increase, compared with the existing land use paddy fields. Heat island phenomenon associated with climate change is also accelerated by the high heat absorption of horticultural sites. Therefore, we analyzed the heat island phenomenon occurring in the facility of horticultural complex in Korea. As an improvement measurement, I examined how much air temperature is reduced by putting the channel and the open space. In the case of the Buyeo area, the Computational Fluid Dynamics (CFD) simulation was analyzed for the average summer temperature distribution in the current land use mode at $38.9^{\circ}C$. As an improvement measurement, CFD simulation after 10% of 6m water channel was found to have an effect of lowering the summer temperature of about $2.7^{\circ}C$ compared with the present average of $36.2^{\circ}C$. In addition, CFD simulations after analyzing 10% of the open space were analyzed at $34.7^{\circ}C$, which is $4.2^{\circ}C$ lower than the present. For the Jinju area, CFD simulations were analyzed for the average temperature of summer at $37.8^{\circ}C$ in the present land use pattern. As an improvement measure, CFD simulations after 10% of 6m water channel were found to have an effect of lowering the summer temperature of about $2.6^{\circ}C$ compared to the current average of $35.2^{\circ}C$. In addition, CFD simulations after analyzing 10% of the open space were analyzed at $33.9^{\circ}C$, which is $3.9^{\circ}C$ lower than the present. It can be said that the effect of summer temperature drop in open space and waterway has been proven. The results of this study are expected to be reflected in sustainable agriculture land use and used as basic data for government - level policy in land use planning for climate change.

순환식 막 모듈 여과장치를 이용한 산성용액의 수처리 공정 시 발생하는 한외여과막 오염에 관한 연구 (A Study on the Fouling of Ultrafiltration Membranes Used in the Treatment of an Acidic Solution in a Circular Cross-flow Filtration Bench)

  • 김남준;최창민;최용훈;이준호;김환진;박병재;주영길;강진석;백윤기
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.252-260
    • /
    • 2009
  • 산성 용액의 수처리가 폴리아크릴로니트릴계 중공사형 한외여과막에 미치는 영향을 십자흐름 방식의 순환식 막 모듈 여과 장치를 이용하여 연구하였다. 막 모듈 여과장치를 이용하여 pH 2인 강산성 용액의 수처리를 시작한 지 약 80시간이 경과되었을 때 막 투과량(permeate flux)이 급격히 감소하는 것을 관측하였다. 또한, 수처리 시간 별로 막 모듈 여과장치의 공급조에서 채취한 샘플 용액의 자외선/가시광선 흡수 스펙트럼과 기체 크로마토그래피/질량분석(gas chromatography/mass spectrometry, GC/MS) 스펙트럼을 분석한 결과 수처리 시간이 경과함에 따라 막 모듈을 통과한 농축액 속에 새로운 유기 화합물이 생성된다는 사실을 알아내었다. 질량스펙트럼 분석을 통해 이 화합물을 1,6-dioxacyclododecane-7,12-dione이라고 예측하였으며, 각종 플라스틱 특히 폴리우레탄 제조 시 사용되는 첨가제 중 하나라는 사실도 알아내었다. 수처리에 사용된 막에 대한 전자주사 현미경 사진 및 고체 NMR 분석 등의 추가 실험을 통해 산성 용액 수처리 과정에서 발생한 막 투과량의 감소는 산성 용액 하에서 일어나는 UF막의 변형에 의한 것이 아니라 막 모듈 여과장치에 사용된 폴리우레탄 튜브에서 산과의 반응에 의해 용출된 저 분자량의 유기화합물이 막 오염 현상을 일으켰기 때문인 것으로 결론지었다. 이번 연구 결과는 산성 용액의 수처리 공정 시 UF막 자체의 산에 대한 반응성 뿐 아니라 막 모듈을 포함한 수처리 장치 자체의 산에 대한 반응성 역시 산 용액의 수처리 효율은 물론, 산을 이용한 막의 화학 세정 효율 및 수처리 막의 pH 사용 한계를 결정하는 데 매우 중요한 요소 중 하나라는 것을 보여준다.

국립생태원 캠퍼스 내 주요 식생의 탄소수지 (Carbon Budget in Campus of the National Institute of Ecology)

  • 김경순;임윤경;안지홍;이재석;이창석
    • 생태와환경
    • /
    • 제47권3호
    • /
    • pp.167-175
    • /
    • 2014
  • 본 연구는 국립생태원 캠퍼스의 탄소수지를 정량화하기 위하여 수행하였다. 현장조사는 국립생태원 캠퍼스의 기존 식생 중 침엽수림과 활엽수림에서 가장 넓은 면적을 차지하고 있는 곰솔군락과 밤나무군락을 대상으로 수행하였다. 순생산량(NPP)은 상대생장법을 적용하여 측정하였고, 토양호흡량은 EGM-4를 적용하여 측정하였다. 곰솔군락과 밤나무군락의 순생산량은 각각 $4.9ton\;C\;ha^{-1}yr^{-1}$$5.3ton\;C\;ha^{-1}yr^{-1}$으로 나타났고, 종속영양생물 호흡량은 각각 $2.4ton\;C\;ha^{-1}yr^{-1}$$3.5ton\;C\;ha^{-1}yr^{-1}$으로 나타났다. 순생산량과 종속영양생물 호흡량을 차감 계산하여 얻은 순생태계생산량(NEP)은 곰솔군락과 밤나무군락에서 각각 $2.5ton\;C\;ha^{-1}yr^{-1}$$1.8ton\;C\;ha^{-1}yr^{-1}$로 나타났다. 본 연구로부터 얻은 곰솔군락과 밤나무군락의 생태계순생산량 지수를 기존 식생에 적용하고 다른 연구로부터 얻은 여러 식생유형의 생태계순생산량 지수를 도입 식생에 대입하여 평가된 국립생태원에 성립된 전 식생의 탄소흡수능은 $147.6ton\;C\;ha^{-1}yr^{-1}$로 나타났고, 이를 이산화탄소로 환산하면 $541.2ton\;CO_2ha^{-1}yr^{-1}$이었다. 이러한 탄소흡수능은 에코리움으로 알려진 유리온실을 비롯하여 국립생태원 내 여러 시설을 운용하며 배출하는 탄소량의 62%에 해당한다. 이러한 탄소상쇄능은 대한민국 국토 전체 및 전형적인 농촌지역인 서천군의 탄소상쇄능의 약 5배에 해당한다. 현재 진행 중인 기후변화가 지구적 차원의 탄소수지 불균형에 기원했음을 고려하면, 본 연구에서 시도한 토지이용 유형을 반영한 공간차원의 탄소수지 평가는 기후변화 문제를 근본적으로 해결하기 위해 요구되는 기초정보를 제공할 수 있을 것으로 판단된다.

수온과 개체크기에 따른 양식산 미더덕, 흰멍게, 진주담치의 여수율 (Filtering Rate with Effect of Water Temperature and Size of Two Farming Ascidians Styela clava and S. plicata, and a Farming Mussel Mytilus edulis)

  • 김용술;문태석
    • 한국수산과학회지
    • /
    • 제31권2호
    • /
    • pp.272-277
    • /
    • 1998
  • 근년에 내만성 굴양식장의 생산성이 저하함에 따라 대체종으로 미더덕과 횐멍게가 주목되면서 이 종들의 생태적 지위가 기존의 양식굴과 상충되는지 여부를 알아보기 위한 일련의 조사계획의 하나로서 여수율을 조사하였으며, 조사결과와 Kim (1995)의 양식굴의 여수율 ($\ast$)을 비교 검토하였다. 1. 폐쇄계에서 해수수온 $10^{\circ}C,\;15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C,\;29^{\circ}C$일때 시간에 따른 현탁색소의 제거율을 측정하고, Kim (1995)의 계산식을 사용하여 여수율을 계산하였다. 현탁색소는 neutral red를 사용하였으며, 22mm 흡수셀을 사용하여 440nm에서 초기흡광도 $0.25\~0.30$을 나타내는 농도를 사용하였다. 2. 여수율은 한시간동안 실험생물 1개체가 여수하는 양을 그 개체의 건조중량으로 나누어서 단위시간당 단위건조육중량당 여수량 (${\ell}/gDW/hr$)으로 산출하고, 이것이 개체 건조육중량과 수온에 의하여 받는 영향을 회귀경향식으로 해석하여, 종별 개체여수율 ($F,\;{\ell}/hr/animal$) 모형으로 다음과 같은 결과를 얻었다. 4. 종별로 수확시의 수온과 개체 평균중량 자료를 사용하여 연승 1대 (100m)당 집단 여수율을 계산한 결과는 다음과 같았다.

  • PDF

새로운 신경전달물질 H2S 발생 효소, cystathionine γ-lyase의 대량발현 조건과 활성측정 (Overexpression and Activity Analysis of Cystathionine γ-Lyase Responsible for the Biogenesis of H2S Neurotransmitter)

  • 김경란;변혜정;조현남;김정현;양선아;지광환
    • 생명과학회지
    • /
    • 제21권1호
    • /
    • pp.119-126
    • /
    • 2011
  • 질병과 밀접한 관계가 있는 hCGL 단백질의 경우 대량 배양 시 유도체를 사용하지 않아도 발현이 되는 점과 유전자 측면에서 조작이 쉬운 E.coli를 이용하여도 발현이 된다는 점에 있어서 중요한 이점을 가지고 있다. 본 연구에서는 배양되는 온도와 발현에 관련 있는 유도체의 농도, 600 nm에서의 균 성장 정도에 따른 유도체의 첨가 그리고 배지의 양을 조절하면서 유입되는 aeration의 조건으로 hCGL 단백질 발현의 최적의 조건 확립을 목적으로 하였다. 또 각 발생되는 inclusion body의 양을 측정하면서 보다 많은 가용성 단백질을 발현시키는 조건을 확립하고자 하였다. hCGL 단백질은 저온에서 보다 많은 양의 단백질이 발현되며 inhibitor의 억제를 담당하는 유도체의 농도와는 상관없이 발현이 되었다. 또한 균의 성장 정도에 따라 유도체의 첨가시기를 달리 하였을 때, 발현 비율에 차이는 있었으나 전체적인 단백질 양과 비교해 보면, 이는 hCGL 발현에 큰 영향을 미치지 않는다. 배지의 양을 달리하여 살펴본 aeration에 따른 hCGL 발현 정도는 배지의 부피가 15%일 때 높은 aeration으로 균의 양은 많았으나 목적 단백질인 hCGL의 발현은 aeration이 되지 않는 조건에서 더 잘되는 것을 확인하였다. 그리고 His-TEV-hCGL의 활성은 야생형 hCGL의 활성을 기준으로 하였을 때, L-cystathionine을 기질로 하였을 경우 76%, L-cysteine을 기질로 하였을 경우 88% 수준으로 유사한 활성을 나타내었고, 이는 손쉽게 정제 가능한 His-TEV-hCGL을 야생형을 대신하여 사용할 수 있음을 시사한다. 또한 His-TEV-hCGL이 야생형 hCGL과 같이, 427 nm에서 흡광을 가지는 것으로 보아 보효소PLP를 포함하고 있음을 알 수 있었다. 이로써 homocysteine 대사연구에 필수적인 hCGL 효소를 다량 얻는 방법을 확립하고, 관련 연구에 기여하리라 사료된다.

중합조건에 따른 dual cured resin cement의 열분석적 연구 (THERMAL ANALYSIS OF THE DUAL CURED RESIN CEMENTS ACCORDING TO CURING CONDITION)

  • 이인복;정관희;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.265-285
    • /
    • 1999
  • The purposes of this investigation were to observe the reaction kinetics of five commercial dual cured resin cements (Bistite, Dual, Scotchbond, Duolink and Duo) when cured under varying thicknesses of porcelain inlays by chemical or light activation and to evaluate the effect of the porcelain disc on the rate of polymerization of dual cured resin cement during light exposure by using thermal analysis. Thermogravimetric analysis(TGA) was used to evaluate the weight change as a function of temperature during a thermal program from $25{\sim}800^{\circ}C$ at rate of $10^{\circ}C$/min and to measure inorganic filler weight %. Differential scanning calorimetry(DSC) was used to evaluate the heat of cure(${\Delta}H$), maximum rate of heat output and peak heat flow time in dual cured resin cement systems when the polymerization reaction occured by chemical cure only or by light exposure through 0mm, 1mm, 2mm and 4mm thickness of porcelain discs. In 4mm thickness of porcelain disc, the exposure time was varied from 40s to 60s to investigate the effect of the exposure time on polymerization reaction. To investigate the effect on the setting of dual cured resin cements of absorption of polymerizing light by porcelain materials used as inlays and onlays, the change of the intensity of the light attenuated by 1mm, 2mm and 4mm thickness of porcelain discs was measured using curing radiometer. The results were as follows 1. The heat of cure of resin cements was 34~60J/gm and significant differences were observed between brands (P<0.001). Inverse relationship was present between the heat of reaction and filler weight % the heat of cure decreased with increasing filler content (R=-0.967). The heat of reaction by light cure was greater than by chemical cure in Bistite, Scotchbond and Duolink(P<0.05), but there was no statistically significant difference in Dual and Duo(P>0.05). 2. The polymerization rate of chemical cure and light cure of five commercially available dual cured resin cements was found to vary greatly with brand. Setting time based on peak heat flow time was shortest in Duo during chemical cure, and shortest in Dual during light cure. Cure speed by light exposure was 5~20 times faster than by chemical cure in dual cured resin cements. The dual cured resin cements differed markedly in the ratio of light and chemical activated catalysts. 3. The peak heat flow time increased by 1.51, 1.87, and 3.24 times as light cure was done through 1mm, 2mm and 4mm thick porcelain discs. Exposure times recommended by the manufacturers were insufficient to compensate for the attenuation of light by the 4mm thick porcelain disc. 4. A strong inverse relationship was observed between peak heat flow and peak time in chemical cure(R=0.951), and a strong positive correlations hip was observed between peak heat flow and the heat of cure in light cure(R=0.928). There was no correlationship present between filler weight % or heat of cure and peak time. 5. The thermal decomposition of resin cements occured primarily between $300^{\circ}C$ and $480^{\circ}C$ with maximum decomposition rates at $335^{\circ}C$ and $440^{\circ}C$.

  • PDF

A research on the introducing the waterproof corrugated cardboard box for the efficient shipment of chinese cabbages and radishes: Focusing on Garak-dong wholesale market as the center

  • Lee, Rae-Hyup;Sun, Il-Suck
    • Asian Journal of Business Environment
    • /
    • 제2권1호
    • /
    • pp.25-34
    • /
    • 2012
  • It is possible to use pallet for forwarding as chinese cabbages and radishes are general large-scale trading items at the agricultural wholesale market though, however, most of these are forwarded as it have packed in net bags or in P·E bags. Thus, it is still hard for palletizing. The type of packing the product in the net bag makes it difficult for palletizing. It is not a stable shape enough and easily collapsed for pallet loading. Because of this collapsibility, the corrugated cardboard box is being used to enhance forwarding efficiency, but the existing corrugated cardboard box could be crushed easily by moist what is from the agricultural product's property and it also could be squashed by the mass of the loaded box layers on itself. In contrary, the functional waterproof corrugated cardboard box is not collapsed through palletizing and it is efficient for product management with it's ventilation function in respond to pre-cooling effect. Furthermore, because it has various functional shapes as the open type, the partition type and so on, it is effective for maintaining freshness of the product and standardizing the distribution of agricultural product. It is well-known that it is possible to introduce this box to cargo-works of agricultural product. Consequently, the recognition of main distributors about the pallet distribution of the chinese cabbage and the radish was apprehended in this study for activating mechanization of loading and unloading. The survey was conducted to the main distributors such as the forwarder, the auction dealer and the commission merchant with Garak-dong wholesale market as the center. The appropriate packing materials and problems of the existing method for loading and unloading were derived through the survey. Especially, it was focused on analyzing the difference of recognition between the subject groups for the way of using waterproof cardboard corrugated box to deal with the difficult product for packing in normal corrugated box because of the box's absorption of moist from the agricultural product like a chinese cabbage and a radish. Total In the cases of the forwarders and the commission merchants, the net was highly responded as 45%, 74% from each groups for the best packing material for mechanization of distribution and the waterproof corrugated cardboard box was responded as 20%, 22% from each groups as much preferable than multi-stage wooden box. However, for the radish, the waterproof corrugated cardboard box was the best material as 56%, and the auction trader group supported it for 80%. So, the using the waterproof corrugated cardboard box for mechanization of distribution was negative for the chinese cabbage, but it was positive for the radish. The average was 2.42, the standard deviation was 1.24. The negative response(about 55%) was prevailing more than positive response(about 23%). It could be analyzed that even there was the positive recognition for using the waterproof corrugated cardboard box for the radish though the preference for low price of net bag in the chinese cabbage forwarding procedure. Still now, it seems that is a burden for using the waterproof corrugated cardboard box with high price. In the analysis on the recognition differences about using the waterproof corrugated cardboard box for the chinese cabbages and the radish between the forwarders and the commission merchants, generally the negative recognition was prevailing, but the forwarders(2.696) were more positive for using the waterproof corrugated cardboard box than the commission merchants(2.145).

  • PDF

여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향 (Effect of polishing methods on color change by water absorption in several composite resins)

  • 김혜진;김미연;송병철;김선호;김정희
    • 구강회복응용과학지
    • /
    • 제35권1호
    • /
    • pp.1-10
    • /
    • 2019
  • 목적: 복합레진의 색조안정성에 있어서 연마가 영향을 주는지 알아보았다. 연구 재료 및 방법: 2 개의 벌크필 레진과 4개의 복합레진을 6 mm 너비, 4 mm 높이로 제작하여 광중합한 후 $34^{\circ}C$ 멸균 증류수에 24 시간 보관하고 분광광도계를 이용하여 CIE $L^*a^*b^*$ 값을 측정하였다. 시편을 연마 방법에 따라 대조군(Mylar strip 그룹), PoGo로 연마한 그룹, Sof-Lex Spiral wheels로 연마한 그룹으로 나누었다(n = 5). 색측정은 4 주 동안 매주 시행하였고 실험 기간 동안 시편은 $34^{\circ}C$ 멸균증류수에 보관하였다. 실험결과는 일반최소자승법으로 통계분석하였다(P < 0.05). 결과: 일반최소자승법 분석에 따르면 Sof-Lex Spiral wheels로 연마한 그룹의 ${\Delta}E$ 값이 PoGo로 연마한 그룹과 대조군의 ${\Delta}E$ 값보다 낮게 나타났다(P < 0.05). 복합레진을 연마한 그룹의 ${\Delta}E$ 값은 연마하지 않은 대조군의 ${\Delta}E$ 값보다 낮게 나타났다(P < 0.05). 복합레진 비교시 Filtek Z250과 Filtek Z350 XT Universal restorative는 모든 기간에서 통계적 차이가 나타나지 않았으며 Tetric N-Ceram Bulk Fill은 1, 2, 3주에서 통계적으로 낮은 ${\Delta}E$ 값을 나타냈다(P < 0.05). 결론: 이번 연구의 한계점을 감안하면 연마 방법은 복합레진의 색조안정성에 영향을 미친다. Sof-Lex Spiral wheels로 연마한 그룹이 PoGo로 연마한 그룹보다 변색에 더 큰 저항을 보여주었다.

가리(加里)와 온도주기성(溫度週期性)이 고구마 생육(生育) 및 인(燐)-32, 가리(加里)-42 동태(動態)에 미치는 영향(影響) (The Behaviors of Phosphorus-32 and Ptoassium-42 under the Control of Thermoperiod and Potassium Level)

  • 김용철
    • 한국토양비료학회지
    • /
    • 제1권1호
    • /
    • pp.89-115
    • /
    • 1968
  • 영양조건(營養條件)으로서 가리(加里)가 대사과정(代謝過程)의 활성화(活性化) 내지조정자(乃至調整者)라는 견지(見地)에서 가리공급수준과(加里供給水準) 생태적조정조건(生態的調整條件)이라고 볼 수 있는 온도주기성(溫度週期性)이 고구마 생육(生育)과 몇 가지 동위원소(同位元素) 동태(動態)에 미치는 영향(影響)을 살피었다. 역경배양하(礫耕培養下) 저수준가리구(低水準加里區)(3m.e/l)는 생장(生長)을 현저(顯著)히 억제(抑制)할 뿐 아니라 말기(末期)에는 대리(待異)한 생장점(生長點) 위조현상(萎凋現象) 등을 나타나게 하였다. 고수준가리구(高水準加里區)(14m.e/l) 특히 암기저온구(暗期低溫區)는 현저(顯著)한 초장(草丈), 마디수(數), 생체중증대(生體重增大)를 가져오고 질소효과와 비슷한 영양생장촉진생육상(營養生長促進生育相)을 나타냈으나 함유질소(含有窒素)를 분석(分析)한 결과 저수준가리구(低水準加里區)가 평균(平均) 2.86~3.23% 고수준가리구(高水準加里區)가 2.91~3.41%로서 큰 차이(差異)를 나타낸 것으로 볼 수 없다. 따라서 고수준가리구(高水準加里區)의 영양생장촉진형(營養生長促進型) 유도(誘導) 특히 초장촉진(草丈促進)은 가리(加里)가 질소흡수(窒素吸收)를 촉진(促進)한데 연유(然由)한 것이 아니라 가리자체(加里自體)의 효과로 보인다. 저수준가리구(低水準加里區)에서는 괴근형성(塊根形成)이 불능(不能)하였지만 고수준가리구(高水準加里區)에서는 영양생장촉진생육상(營養生長促進生育相)에 수반하며 질소효과와는 달리 후기(後期)에는 괴근형성(塊根形成)도 왕성(旺盛)하였다. 고수준가리구중(高水準加里區中)에서도 암기저온구(暗期低溫區)에서는 더욱 영양생장촉진경향(營養生長促進傾向)이 원저(願著)하고 암기고온구(暗期高溫區)에서는 지상부대지하부비(地上部對地下部比), 또는 괴근비(塊根比)가 월등(越等)하여 원래(元來)의 온도주기성(溫度週期性)의 효과가 고수준가리(高水準加里)에 의(依)하며 변화(變化)된 것으로 보인다. 인(燐)-32 가리(加里)-42의 개체당(個體當) 흡수(吸收) 및 흡수율(吸收率)은 고수준(高水準) 가리구(加里區)에서 현저(顯著)하고 특(特)히 괴근형성기(塊根形成期) 및 괴근생성(塊根生成)이 가장 왕성(旺盛)한 구(區)에서 증대(增大)되고 있나 p-32보다 k-42동태(動態)가 이점(點)에 관하여 더 활발(活潑)한 것을 볼 수 있다. 저수준가리구(低水準加里區)에서는 P-32, K-42의 지상부(地上部)로의 이동(移動)이 억제(抑制)되고 고수준가리구(高水準加里區)에서는 촉진(促進)되고 있다. 즉 가리(加里)가 인(燐)-32와 가리(加里)-42의 지상부전이(地上部轉移) 특(特)히 생장점(生長點)으로의 전이(轉移)에 밀접(密接)한 관계(關係)를 가지고 있다. 가리함량(加里含量)은 고수준가리구(高水準加里區)에서 높고 근신장기(根伸長期)보다 괴근형성기(塊根形成期)에 감에 따라 증가(增加)되고 있지만 인산함량(燐酸含量)은 별차이(別差異)가 없고 나토리움함량(含量)은 가리(加里)와 대조적(對照的)으로 정반대(正反對)의 경향(傾向)을 나타내고 있다. 가리(加里)는 온도주기성(溫度週期性)의 관여하(關與下) 고구마생장(生長)에 지리(持異)한 효과를 나타내고 또 P-32, K-42이동(移動)등 기본적(基本的) 대사과정(代謝過程)에 관여(關與)하기 때문에 공급량(供給量)이나 조건(條件)에 따라서 다양적효과를 가질 수 있는 영양요소(營養要素)라고 본다. 본연구(本硏究)를 지도(指導)하신 조백현원자력위원(趙伯顯原子力委員)과 협조(協調)하여주신 국제원자력기구(國際原子力機構) 및 가리연구회(加里硏究會)에 심사(深謝)한다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF