• 제목/요약/키워드: Absorbent biofilter

검색결과 9건 처리시간 0.017초

농업수자원으로서의 흡수성 Biofilter 처리수 재이용 (Reuse of Treated Sewage Water from Absorbent Biofilter System as Agricultural Water Resources)

  • 권순국;김현욱;권용웅;조영현;박상원;임경래
    • 한국농공학회지
    • /
    • 제45권5호
    • /
    • pp.151-159
    • /
    • 2003
  • Absorbent Biofilter Systems (ABS), composed of an anaerobic septic tank, a pump chamber and an absorbent biofilter tank, have been found to economically provide rural on-site wastewater treatment. This study was conducted to assess the potential of ABS effluent as an alternative water resource for agricultural and environmental use, with respect to the removal of pathogenic microorganism and their fertilization effect. A pilot scale ABS was used to compare its removal efficiency of pathogens from effluent water. Overall, more than 95 percent of Salmonella and E. coli were removed. This result demonstrates that a significant reduction in the pathogenic microorganism of effluents can occur in ABS, which implies the feasibility for the use of ABS effluent in agriculture and environment, with the provision of a further simple disinfection step, in order to satisfy the WHO guidelines for the microbiological quality in agriculture. In addition, because of the abundant nutritional content of ABS effluent, the substitution effect of fertilizer (N, P and K) in paddy irrigation, i.e. 2/3 for nitrogen, l/3 for phosphorus and 1/5 for potassium would be expected. Based on the experimental data, the ABS effluent could be used as a new alternative water resource for paddy irrigation, as well as for environmental purposes, such as supplying water to ecological parks in rural villages.

흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능 (Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas)

  • 권순국;윤춘경
    • 한국환경농학회지
    • /
    • 제18권4호
    • /
    • pp.310-315
    • /
    • 1999
  • 본 연구에서는 생물막법의 일종인 흡수성 Biofilter 시스템(ABS)을 설치하여 14개월의 실험기간 동안 건국대 농생대 구내의 염기성 부패조로부터 유입수를 3가지 수리부하율로 처리하여 시험하였다. 모니터링 결과에 의하면 ABS는 평균농도 $BOD_5=6.2mg/l$, TSS=4.4mg/l 이라는 아주 낮은 유기성 유출수를 연속적으로 발생시킬 수 있음이 확인되었다. 이러한 저농도 유출수는 현재 우리나라 오분법의 특정지구(상수원 보호구역)에 대한 방류수 기준($BOD_5=10mg/l$, TSS=10mg/l)에도 훨씬 못 미치는 양호한 농도로서 ABS의 우수한 유기성오수 처리성능이 입증되었다. 특히 유출수내의 TSS 농도가 지극히 낮아서 슬러지의 발생이 거의 없으므로 침전조를 생략할 수 있어 설치비용이 저렴해지고, 유지관리가 단순한 장점을 지니고 있음을 알 수 있었다. 그러나 ABS시설이 농촌에 널리 보급되어 실용적인 시스템이 되기 위해서는 앞으로 T - N과 T- P의 처리효율 향상 방안, 겨울철에 대한 Biofilter탱크내 임계온도 유지문제, 광역모니터링 및 신속보수 유지관리체계 확립에 대한 계속적인 연구가 필요하다. 이러한 문제점만 어느정도 해결된다면 ABS는 우리나라 농촌의 소규모 현장 오수처리시설로서 앞으로 미래가 밝은 차세대형 시스템이 될 것으로 확신한다.

  • PDF

수리부하량 변화에 따른 바이로필터의 처리효율에 관한 연구 (The Effect of Hydraulic Loading on the Performance of Biofilter System)

  • 방천희;김철성;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.789-794
    • /
    • 1999
  • The performance of a small on-site wastewater treatment system consisting of an anaerobic septic tank and upgraded absorbent biofilter was investgted . The anaerobic septic tank was used as a pre-treatment of the absorbent Biofitler instead of the primary clarifier. The treatment capacity of the system was examined by changing the hydraulinc loadings to the Absorbent Biofilter as 2.5㎥/day , 4.5㎥/day, 6.0㎥/day, respective. The effluent from the septic tank was fed into the Absorbent Bilfilter. Based on the experimental results, the quality of treated wastewater satisfied the regulation and the BOD and SS was removed down to approximately 5mg/$\ell$ and 1mg/$\ell$, respectively.

  • PDF

소규모 오수처리 시스템에서의 제올라이트에 의한 질소 제거 (Nitrogen Removal using Zeolite at On-site Wastewater Treatment System)

  • 방천희;권순국
    • 한국농공학회지
    • /
    • 제44권2호
    • /
    • pp.161-173
    • /
    • 2002
  • Recently, absorbent biofilters, which are inexpensive and easy to manacle, have been supplied to the rural areas, but have limitations in removing the nutrients effectively. Accordingly, as an alternative plan. natural zeolites were arranged in front or at the rear of the absorbent biofilters, and their removal efficiency for nitrogen and, ultimately, their applicability to the on-site wastewater treatment system were studied. Furthermore, the same experiments were carried out on artificial zeolites, made from coal ashes at National Honam Agricultural Experiment Station, to compare natural zeolites with artificial ones. Treated wastewater through the Absorbent Biofilter showed 22.6% nitrogen removal efficiency, while 64.6% was attained when natural Zeolites were placed in front of the absorbent biofilters (Zeolite-Aerobic process). As an addition, phosphorus was also efficiently removed. On the other hand, Aerobic-Zeolite process, which arranged natural zeolites at the rear of the biofilters, did not have significantly higher nitrogen removal as compared to the treatment using only the absorbent biofilters. Furthermore, upon regeneration of the natural zeolite, the ion exchange rate was fecund to increase over 10% as compared to before regeneration. Our results show that natural zeolites, applied to the on-site wastewater treatment system through the Zeolite-Aerobic process, not only increase the removal efficiency of nutrients, but, by choosing the appropriate regeneration time, can also be cast-effective. Artificial zeolites, on the other hand, though more efficient in removing nutrients, cannot be regenerated and, therefore, are not cost-effective.

흡수성 바이오필터 시스템의 오수처리 특성 및 효율 (Sewage Treatment Characteristics and Efficiencies of Absorbent Biofilter Systems)

  • 전기설;권순국;김성배
    • 한국농공학회논문집
    • /
    • 제46권5호
    • /
    • pp.131-139
    • /
    • 2004
  • In this study, on-site sewage treatment tests were conducted using the Absorbent Biofilter System (ABS) under different hydraulic loading rates to examine its treatment characteristics and efficiencies and to determine its feasibility as a small on-site sewage treatment system in a rural area. Results showed that the removal rates of BOD and SS were satisfactory at hydraulic loading rates of 100~150 cm/day, meeting the Korean effluent water quality standards for the riparian zone (10 mg/L). In the case of nutrients (N, P), however, the system did not perform well, necessitating further improvement for nutrient removal. A comparative analysis indicated that as a small on-site sewage treatment system, the ABS would be more suitable than other treatment systems in terms of performance stability, maintenance requirement, and cost-effectiveness and could be applied as an alternative treatment system in Korean rural areas.

재순환에 의한 흡수성 바이오필터 시스템의 오수처리효율 향상 (Enhancement of Sewage Treatment Efficiencies by Recirculation in Absorbent Biofilter System)

  • 권순국;전기설;김성배
    • 한국농공학회논문집
    • /
    • 제47권3호
    • /
    • pp.69-76
    • /
    • 2005
  • An Absorbent Biofilter System (ABS) combined with the recirculation process was investigated for the feasible application in additional removing of organics (BOD, SS) as well as nutrients (TN, TP) from small Community wastewater in Korea. Polyurethane biofilter media with high porosity and large surface area were /used for the aerobic system. A part of treated wastewater was recirculated into the anoxic septic tank to promote removal of nutrients. The concentrations of BOD and SS of treated wastewater satisfied the regulations for small on-site wastewater treatment facility (10 mg/L) during the overall experimental period. The effluent concentrations of BOD and SS were decreased with enhancement of removal efficiencies of 95.7 and $96.7\%$. The nitrogen and phosphorus removal efficiencies by the recirculation increased to $52.9\%\;and\;43.2\%$ in average during the overall experimental period, respectively. With the improvement, these values were increased as much as additional 42 and $18\%$ compared with those of non-recirculation. The rates of nitrification and denitrification were enhanced showing $65\~77\%\;and\;42\~92\%$, respectively. The described process modification is a low cost and effective method of enhancing nitrogen and phosphorus removal, especially on existing systems without changing major design components of a treatment facility.

흡수성 Biofilter System에서 동절기 가온이 처리 특성과 성능에 미치는 영향 (Effects of Winter Heating on the Treatment Characteristics and Performance of Absorbent Biofilter System)

  • 권순국;전기설;김성배
    • 한국농공학회논문집
    • /
    • 제47권6호
    • /
    • pp.73-82
    • /
    • 2005
  • This study was performed to evaluate the need for heating wastewater to enhance treatment efficiency of organic matter (BOD, SS) during cold winter in newly developed Absorbent Biofilter System (ABS) which was established in the Suwon Campus of the Seoul National University. Treatments consisted of non-heating (2000 year) and heating(2001, 2002 year), and sampled data were analyzed during cold winter period as well as post winter period to investigate the influence of heating after winter season. Even the average air temperature showed only $0.4^{\circ}C$ difference between two experimental years, the difference in the average effluent temperature during cold winter period between heating and non-heating experiment was approximately $11^{\circ}C$. The average effluent concentration of organic matter in non-heating treatment exceeded the Korean standards for water quality of discharged effluent in riparian area (BOD and SS 10 mg/L); however, the standards were met in case of heating treatment during both winter and post winter period. Therefore, the need fur heating wastewater during cold winter season in ABS was justified. On the other hand, there was no improvement of treatment efficiency in T-N and T-p, but we observed the more activated nitrification as increasing the wastewater temperature. Because the average underground temperature was $5^{\circ}C$ higher than the average air temperature during cold winter period, we recommend that the ABS can be established in the underground rather than on-ground for saving the heating cost.

생물막법에서 여재의 종류에 따른 유기성 오수의 처리 특성에 관한 연구 (A study on the characteristic of organic wastewater treatment in biofilm reactor with five types of media)

  • 주욱종;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.508-512
    • /
    • 1998
  • Recently, biofilm reactors are considered as efficient wastewater treatment system in rural areas, because of characteristics of easy operation and economic feasibility. In order to select the most efficient media, an experimental apparatus with five different media was designed, installed and examined. The media used in this study were zeolite, artificial sponge gourd, absorbent biofilter, non-woven fabric and charcoal. With only one month investigation, all five media showed high removal efficiencies of BOD.

  • PDF

소규모 오수처리시스템에서의 제올라이트에 의한 암모니아성 질소 제거(지역환경 \circled3) (Ammonia Removal by Use of Zeolite at Small Wastewater Treatment System)

  • 방천희;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.643-648
    • /
    • 2000
  • The purpose of this study is to remove the ammonia by using the ion exchange effect of natural zeolite (clinoptilolite in this system) and artificial zeolite and remove the organic material by using the Absorbent Biofilter. On the removal of ammonia, natural zeolite is the more effective than artificial zeolite But on the simultaneous removal of ammonia and phosphorus, artificial zeolite is the more effective than natural zeolite.

  • PDF