• 제목/요약/키워드: Absorbed Spectrum

검색결과 64건 처리시간 0.02초

A Study on Electric Properties of Polyamide Film due to Temperature Change

  • Lee, Sung Ill
    • Elastomers and Composites
    • /
    • 제54권1호
    • /
    • pp.1-6
    • /
    • 2019
  • In this study, we measured the leakage current at $30{\sim}80^{\circ}C$ and $90{\sim}170^{\circ}C$ under a voltage of 200~980 V applied to samples (ordinary temperature) and polyamide film specimens degraded at $170^{\circ}C$ for 20 minute respectively. After the specimen was degraded at $130^{\circ}C$ and $50^{\circ}C$, a voltage of 200 to 800 V was applied for 10 to 60 minutes. The measurement of the leakage current resulted in the following conclusions. In the case of using Al and Cu as the main electrode, it was confirmed that the leakage current also increased in high temperatures as the voltage increased. Regardless of the type of main electrode, when the temperature was constant at $130^{\circ}C$ and $50^{\circ}C$, the leakage current increased as the voltage increased, and gradually decreased with time. As a result of the FTIR measurement, the main absorption of the infrared absorption spectrum was C=O at about $1650cm^{-1}$ and N-H diagonal vibration occurred at around $1550cm^{-1}$. There was no change in the material, so no effect of temperature was observed. By the results of SEM measurements, as the temperature of degradation increases, cracks in the specimen disappear. This may be because the amide bond (-CO-NH-) is absorbed by the material.

Adsorption Characteristics of Al (III), Ni (II), Sm (III) Ions on Resin with Styrene Hazardous Material in Reinforcement Water Fire Extinguishing Agent

  • Kim, Joon-Tae
    • 통합자연과학논문집
    • /
    • 제6권3호
    • /
    • pp.151-157
    • /
    • 2013
  • The ion exchange resins were synthesized from 1-aza-18-crown-6 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous material) divinylbenzene (DVB) copolymer with crosslinks of 1%, 6%, and 15% by substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, surface area, and IR-spectrum. The object of this study was to seperate the metal ion absorbed in reinforcement water fire extinguishing agent. As the results of the effects of pH, equilibrium arrival time, and crosslink of synthetic resin on metal ion adsorption for resin adsorbent, the metal ions were showed high adsorption at pH 3 or over and adsorption equilibrium of metal ions was about 2 hours. In addition, adsorption selectivity for the resin in water was the order of Al (III) > Ni (II) > Sm (III) ions, adsorbability of the metal ions was in the crosslinks order of 1%, 6%, and 15%.

함수의 천일증발촉진성 색소에 관한 시험 (Study on the dyestuff for acceration solar evaporation)

  • 장판섭
    • 약학회지
    • /
    • 제3권1호
    • /
    • pp.26-34
    • /
    • 1957
  • The solar evaporation method is one of the most important and popular salt manufecturing method in Korea. The rate of evaporation of sea water depends on a complex climate factors. Of these factors, the most important is solar radiation and in particular the extent to which it is absorbed in the brine. By the addition of suitable dyestuff, a further increase in absorption is obtained and can result in all the radiation entering the brine being made available as heat. "Solivap Green", one of several dyestuffs which have been suggested for accelerating solar evaporation, was tested in this experiment. The results of the experiment. 1. Increase the evaporation rate of brine up to 20-25%. 2. Elevate the temperature of brine 2-$4^{\circ}C$. higher than that of brine adding no dyestuff. 3. Optimum dyestuff concentration is 25-30 mg/L and allowable maximum concentration can not exceeded 1000 mg/$m^2$ (50 mg/L). 4. Addition of dyestuff does not cause the degradation of salt produced. 5. A conversion table which indicates the concentrations for various depths of brine was prepared for engineering purpose. 6. Absorption spectrum of the dyestuff was studies, but toxicological and structural studies for the dyestuff have not been done in this experiment.

  • PDF

산업설비의 전자파 장해환경 분석 (Analysis of Electromagnetic Wave Interference Environment to Industrial Machinery)

  • 홍용규;김태현;김덕근;임장섭;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1835-1837
    • /
    • 2001
  • The interference of electromagnetic waves in factory is increasing according with development of industrial society and many use of electrical machinery. Electromagnetic wave is defined as the electrical and magnetic field formed by electrical and electronic equipment used in daily lives, which indiscriminatingly affects the human health and operation of machinery. The electromagnetic spectrum ranges from the shorter wavelengths(including gamma and x-rays) to the longer wavelengths(including microwaves and broadcast radio waves). Radiation that is not absorbed or scattered in the atmosphere can reach and affect on the operation of machine. In this study, electromagnetic wave that is interfered to the machine and human is detected in factory, and decrease method of electromagnetic wave interference is studied.

  • PDF

APPLICATION OF WHOLE BODY COUNTER TO NEUTRON DOSE ASSESSMENT IN CRITICALITY ACCIDENTS

  • Kurihara, O.;Tsujimura, N.;Takasaki, K.;Momose, T.;Maruo, Y.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.249-253
    • /
    • 2001
  • Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of $^{24}Na$ in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of $^{24}Na$ is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 $[(Bq^{24}Na/g^{23}Na)/mGy]$.

  • PDF

조직 등가 섬광체를 이용한 계수형 선량계의 개발과 특성 평가 (Development and Characterization of a Dosimeter Using Tissue-Equivalent Scintillator by Photon-Counting Method)

  • 천종규;김성환;김홍주
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2014
  • A dosimeter using tissue-equivalent scintillator by photon-counting method was developed and evaluated in its performance. The dosimeter is portable and can be operated by low power from lap-top computer. A data-acquisition software of the dosimeter system was developed by Labwindows/CVI based on Windows. The energy to channel ratio for energy calibration was 0.839 keV/ch. obtained from pulse height spectrum of $^{137}Cs$ and $^{60}Co$ gamma-ray. Using the dosimeter system, the absorbed dose of environmental radiation in Gyungju was 0.18 ${\mu}Sv/h$.

Valerian의 구성성분 및 이소발레르아미드에 관한 연구 (Studies on the Components of Valerian and Isovaleramide)

  • 박현정;이상협
    • 약학회지
    • /
    • 제54권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Valerian (Valeriana officinalis L.) is a perennial that has been used for medicinal purposes from the ancient times and valerian preparations including root and rhizome extracts are known to possess a variety of biological activities such as anticonvulsant, antidepressant, sleep aid, tranquilizer, and anti-HIV activities. Main components of the extracts were classified according to the structural features. Importantly, one of the main components, isovaleramide, has drawn our attention due to the concise structure, broad spectrum, and low toxicities. The general aspects including generation of this interesting molecule, a variety of activities, pharmacokinetic properties, derivatization, and fusion with other known drugs were described. Isovaleramide has been isolated from valerian probably as an isolation artifact after treatment of ammonia to prepare ammoniated tincture, and is known to exhibit anticonvulsant, anxiolytic, sedative, and sleep aid activities without distinct side effects such as excessive sedation and decreasing muscle tone. It was also found to be well absorbed into the circulation system without specific cytotoxicity and genotoxicity. The derivatives of isovaleramide, valpromide, valrocemide and valnoctamide were also briefly discussed.

전자스핀공명법(ESR)을 이용한 방사선조사 조제유류의 판별 (Detection of Irradiated Milk Formulas using Electron Spin Resonance)

  • 운재호;박병룡;최병국;김나영;정홍점;정기수;김희선;김창섭
    • Journal of Dairy Science and Biotechnology
    • /
    • 제28권2호
    • /
    • pp.13-18
    • /
    • 2010
  • 방사선 조사된 완제품 조제분유를 포함한 시료 4종의 ESR 스펙트럼 특성을 측정하였다. 조제분유와 전지분유의 비조사 시료는 g=2.0050의 아주 약한 singlet 형태의 스펙트럼을 나타내었다. 조사 시료에서 전지분유는 g=2.0050의 singlet 형태의 스펙트럼, 조제분유는 전지분유와 같은 중심 피크 옆에 g=2.0006의 작은 피크를 가진 비대칭 형태의 스펙트럼을 나타내었고, 두 시료 모두 비조사 시료와 조사 시료의 신호 세기 차이가 명확하여 조사유무 판별이 가능하였다. 포도당과 유당의 비조사 시료는 아무런 시그널을 나타내지 않았으며, 조사 시료는 이미 알려져 있는 결정형 당 유래의 다형 피크를 가진 스펙트럼을 나타내었다. 선량이 증가함에 따라 신호 세기도 증가하였고, 회귀방정식의 상관계수는 0.95 이상의 높은 값을 나타내었다. 감마선과 전자선 조사에 의한 ESR 스팩트럼 간의 유의성 있는 차이는 없는 것으로 확인되었다. 결론적으로 본 실험을 통하여 ESR 분석은 방사선 조사된 조제분유 및 원료의 판별에 유용한 방법으로 적용될 수 있는 것으로 판단되었으며, 온도, 습도 및 전처리 조건 등의 요인에 의한 변화 가능성과 식품 생산 및 장기유통 기간 등을 고려할 때 이에 대한 지속적인 연구와 자료 축적이 요구된다고 할 것이다.

  • PDF

감마선 조사가 마늘(Allium sativum) 단백질 Allivin의 구조적 변화에 미치는 영향 (Effect of Gamma Irradiation on the Conformational Changes of Garlic (Allium sativum) Protein, Allivin)

  • 김미리;이주운;변명우;서지현;육홍선;김미정
    • 한국식품영양과학회지
    • /
    • 제31권5호
    • /
    • pp.723-727
    • /
    • 2002
  • 감마선 조사에 의 한 마늘의 주요 알러젠 단백질인 allivin의 구조적 변화를 관찰하였다. Allivin 용액 (3.0 mg/mL in 0.01 M PBS, UH 7.4)과 생 마늘에 2.5, 5.0, 7.5, 10.0 kGy의 흡수선량을 갖도록 감마선을 조사하였다. 조사 후 용액의 절반을 0.22$\mu\textrm{m}$ filter로 여과하여 준비하였다. 감마선 조사에 의한 allivin의 변화는 UV spectrum과 SDS-PAGE를 사용하여 관찰하였다. 가시적으로 관찰하였을 때, 조사선량이 증가할수록 allivin 용액의 혼탁도가 증가하였으며 ,660 nm 파장에서의 흡광도의 증가로 확인할 수 있었다. 조사 후 여과한 allivin 용액의 UV spectrum 측정에서 혼탁도의 변화가 크게 감소되었으며, 선량이 증가할수록 용해된 단백질의 농도가 소하였다. SDS-PAGE시험에서 감마선 조사된 allivin의 큰 변화는 관찰되지 않았으나, 분자간 응집이 관찰되었다 그러나, 조사 후 여과한 시료에서 는 allivin의 감소가 관찰되었으며, 분자간 응집으로 발생된 끌림도 감소하였다. 생마늘에 대한 전기영동 결과는 차이가 없었다. 이 결과들은 감마선 조사가 수용액 상태에서 allivin의 알러지성을 감소시킬 수 있음을 시사한다.

디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구 (Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography)

  • 김호경;조민국
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.