• 제목/요약/키워드: Absorbable suture

검색결과 67건 처리시간 0.031초

골막하 박리와 흡수성 봉합사에 의한 눈썹과 광대지방층의 거상술 (Eyebrow Lift and Malar Fat Lift by Absorbable Suture Fixation with Subperiosteal Dissection)

  • 정재훈;이윤호;장충현
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.262-266
    • /
    • 2005
  • In some blepharochalasis patients, upper blepharoplasty alone is not satisfactory because of narrow distance between eyebrow and eyelash. On that occasion, eyebrow lift is advisable. There are many methods of classical eyebrow lift, such as direct excision, transblepharoplasty approach, anterior hairline technique, and so on. But they are not so effective, have a tendency to recur and also give rise to side effects; unacceptable scar, facial nerve palsy, sensory loss and hematoma, etc. Some patients who have prominent nasolabial folds, are reluctant to perform face lift procedure due to psychologic or economic burden. The authors performed the eyebrow lift procedure separately or simultaneously with face lift or forehead lift. After making 2 or 3 slit incisions, we passed absorbable suture material, 3-0 vicryl, through suborbicularis oculi fat layer. Then it was passed through subperiosteal plane and fixated to the temporalis fascia. When patients complain prominent nasolabial folds, malar fat pad was elevated also in the same manner. This methods is effective and has minimal complication such as facial nerve palsy, scar, sensory loss. Recurrent tendency was rarely observed during follow-up. Dimples were observed at slit incision sites but they disappeared within 2 or 3 weeks. Eyebrow lift and malar fat lift by absorbable suture elevation with subperiosteal dissection is a simple and less morbid. Because of its effectiveness and little side effect or complication, this procedure can be a useful method.

Importance of various skin sutures in cheiloplasty of cleft lip

  • Kim, Soung Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권6호
    • /
    • pp.374-376
    • /
    • 2019
  • Last week, after our receiving online journal regarding Journal of the Korean Association of Oral and Maxillofacial Surgeons, we found a recently published original article by Alawode et al., entitled "A comparative study of immediate wound healing complications following cleft lip repair using either absorbable or non-absorbable skin sutures". Although this clinical article was well written and provided a great deal of information regarding the suture materials in the cleft lip repair, I would like to add a few additional comments based on the importance of skin suture during cheiloplasties in the primary cleft lip or secondary revision patients with representative figures.

봉합결찰법을 이용한 골절된 상악동 전벽의 정복과 고정 (Reduction and Fixation Methods for Fractured Anterior Maxillary Sinus Wall Using Suture Tie)

  • 정현교;강재경;송정국;신명수;윤병민
    • 대한두개안면성형외과학회지
    • /
    • 제14권2호
    • /
    • pp.111-114
    • /
    • 2013
  • The anterior maxillary sinus walls are the most frequently injured sites in midfacial fractures. The maxillary sinus is a difficult surgical site for reduction and fixation due to its narrow surgical field, and has a chance of developing sinusitis when sufficient treatment is not given. In this study, the methods developed by the authors for managing such are introduced. Two small openings were made on both sides of the fracture line, then a suture knot was tied instead of wiring for reduction and fixation. Then an absorbable mesh was applied on top of the fracture site, with a suture knot for additional fixation. This method was applied on an actual patient, and it was a convenient method despite the narrow surgical field that was provided. The authors believe that using suture knots to fixate fractured segments and absorbable mesh is relatively convenient and economically efficient when it comes to the reduction and fixation of the maxillary sinus wall fracture with several fragments.

The effect of suture by absorbable material on corneal astigmatism after phacoemulsification

  • Yoo, Jae Ho;Lee, Sang Joon
    • 고신대학교 의과대학 학술지
    • /
    • 제33권3호
    • /
    • pp.318-327
    • /
    • 2018
  • Objectives: To investigate the effect of absorbable suture on surgically-induced corneal astigmatism in 3.0-mm sclera tunnel cataract surgeries. Methods: Medical records of patients who underwent phacoemulsification cataract surgery using a 3.0-mm sclera tunnel incision made by a single surgeon were reviewed. Uncorrected distant visual acuity, corneal astigmatism and surgically-induced astigmatism were measured in 56 patients' eyes that underwent sclera tunnel cataract surgery with absorbable sutures (sutured group) and in 23 patients' eyes without sutures (unsutured group). Uncorrected visual acuity, intraocular pressure, slit lamp examination, and automated keratometry were evaluated preoperatively and at 3 days, 2 weeks, 4 weeks, and 8 weeks after cataract operation. Results: There were no significant differences in preoperative average uncorrected distant visual acuity of the two groups (sutured group: $0.79{\pm}0.64$, unsutured group: $0.68{\pm}0.72$, P = 0.145). Corneal astigmatism measured using keratometry in the sutured and unsutured group at postoperative day 3 were $2.27{\pm}2.12D$ versus $0.83{\pm}0.55D$ at (P < 0.001), a difference which had disappeared after 4 weeks. Surgically induced astigmatism using the Holladay and Vector methods showed similar outcomes, suggesting that the sutured group exhibited higher astigmatism compared with the unsutured group until 2 weeks post-surgery. Conclusions: TPatients undergoing scleral tunnel cataract surgery with absorbable sutures have greater surgically induced astigmatism, especially in the early postoperative period, compared with those without sutures. However, this surgically induced astigmatism due to absorbable sutures in scleral tunnel cataract surgery is temporary and disappears at 4 weeks post-surgery.

Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응 (TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS)

  • 서민정;이재훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권3호
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

가토에서 Ethicon과 AILEE사 Coated Vicryl의 상호비교 (Comparative Study of Coated Vicryl Made by Ethicon and AILEE in Rabbits)

  • 유원민;박상현;노태석;박철;탁관철
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권1호
    • /
    • pp.49-54
    • /
    • 2001
  • Sutures support wound healing during the initial phase. As the tensile strength of a wound increases, the need for the presence of sutures becomes less important. For this reason, absorbable suture materials have been sought. Nowadays, commonly used suture materials are Chromic Catgut, Coated Vicryl, and PDS. Among these materials, Coated Vicryl is the most popular. Studies were conducted to compare the handling properties, reliability of knots, wound healing, and tissue reactivity(Inflammation, Fibroblast proliferation, Collagen deposition, Giant cell reaction, Absorption) between AILEE vicryl and ETHICON vicryl. We used twelve purebred New Zealand white rabbits, and biopsied the tissue at three, seven, fourteen, and thirty days post implantation. The results showed that both were supple and easy to handle and tie, and gross and histologic differences were not apparent.

  • PDF

Evaluation of tensile strength of surgical synthetic absorbable suture materials: an in vitro study

  • Khiste, Sujeet Vinayak;Ranganath, V.;Nichani, Ashish Sham
    • Journal of Periodontal and Implant Science
    • /
    • 제43권3호
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the tensile strength of surgical synthetic absorbable sutures over a period of 14 days under simulated oral conditions. Methods: Three suture materials (polyglycolic acid [PGA], polyglactin [PG] 910, and poly (glycolide-co-${\epsilon}$-caprolactone) [PGC]) were used in 4-0 and 5-0 gauges. 210 suture samples (35 of each material and gauge) were used. All of the samples were tested preimmersion and 1 hour and 1, 3, 7, 10, and 14 days postimmersion. The tensile strength of each suture material and gauge was assessed. The point of breakage and the resorption pattern of the sutures were also assessed. Results: During the first 24 hours of immersion, all 4-0 and 5-0 samples of PGA, PG 910, and PGC maintained their initial tensile strength. At baseline (preimmersion), there was a statistically significant (P<0.001) difference in the tensile strengths between the 4-0 and 5-0 gauge of PGA, PG 910, and PGC. PGA 4-0 showed the highest tensile strength until day 10. At 7 days, all the 4-0 sutures of the three materials had maintained their tensile strength with PGA 4-0 having significantly greater (P=0.003) tensile strength compared to PG. Conclusions: 4-0 sutures are stronger and have greater tensile strength than 5-0 sutures. The PGA 4-0 suture showed the highest tensile strength at the end of day 10.