• Title/Summary/Keyword: Absorbable

Search Result 259, Processing Time 0.019 seconds

Vessel Remodeling after Intima-to-Intima Contact Anastomosis

  • Yeo, Hyeonjung;Kim, Hyodong;Son, Daegu;Hong, Changbae;Kwon, Sun Young
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • Background Intima-to-intima microanastomotic vascular remodeling was explored, utilizing a polylactide-caprolactone absorbable vein coupler model (PAVCM), which was designed to simulate a non-absorbable counterpart system with the sole exception of being absorbable. Methods Six New Zealand white rabbits were used. After transection of the jugular vein, 2 PAVCMs were placed, 1 at each transected end. The stumps were slipped through the PAVCMs, and the venous wall was everted $90^{\circ}$ to achieve intima-to-intima contact. Reanastomosis of the transected jugular vein was performed bilaterally in 3 rabbits. In the other 3 rabbits, the jugular vein (20 mm) harvested from one side was interpositionally grafted to the jugular vein on the opposite side to ease the anastomotic tension. Patency testing, ultrasonography, and histologic assessments were conducted postoperatively at weeks 2, 4, 12, 16, 22, and 26. Results All anastomotic sites were patent, without stenosis, occlusion, or dilatation. In the histologic sections, immature endothelial regeneration was observed at week 2, which was completed by week 4. Regeneration of the tunica media was noted at week 12. Between week 22 and week 26, the tunica media fully regenerated and the coupler dissipated entirely. Conclusions Despite the absence of a coupler to act as an anastomotic buttress, the structure and function of all the vessels appeared normal, even histologically. These outcomes are true milestones in the development of an absorbable vein coupler.

Correction of post-traumatic enophthalmos with anatomical absorbable implant and iliac bone graft

  • Choi, Ji Seon;Oh, Se Young;Shim, Hyung-Sup
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.6
    • /
    • pp.361-369
    • /
    • 2019
  • Background: Trauma is one of the most common causes of enophthalmos, and post-traumatic enophthalmos primarily results from an increased volume of the bony orbit. We achieved good long-term results by simultaneously using an anatomical absorbable implant and iliac bone graft to correct post-traumatic enophthalmos. Methods: From January 2012 to December 2016, we performed operations on seven patients with post-traumatic enophthalmos. In all seven cases, reduction surgery for the initial trauma was performed at our hospital. Hertel exophthalmometry, clinical photography, three-dimensional computed tomography (3D-CT), and orbital volume measurements using software to calculate the specific volume captured on 3D-CT (ITK-SNAP, Insight Toolkit-SNAP) were performed preoperatively and postoperatively. Results: Patients were evaluated based on exophthalmometry, clinical photographs, 3D-CT, and orbital volume measured by the ITK-SNAP program at 5 days and 1 year postoperatively, and all factors improved significantly compared with the preoperative baseline. Complications such as hematoma or extraocular muscle limitation were absent, and the corrected orbital volume was well maintained at the 1-year follow-up visit. Conclusion: We present a method to correct enophthalmos by reconstructing the orbital wall using an anatomical absorbable implant and a simultaneous autologous iliac bone graft. All cases showed satisfactory results for enophthalmos correction. We suggest this method as a good option for the correction of post-traumatic enophthalmos.

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF

Comparison of Absorbable Mesh Plate versus Titanium-Dynamic Mesh Plate in Reconstruction of Blow-Out Fracture: An Analysis of Long-Term Outcomes

  • Baek, Woon Il;Kim, Han Koo;Kim, Woo Seob;Bae, Tae Hui
    • Archives of Plastic Surgery
    • /
    • v.41 no.4
    • /
    • pp.355-361
    • /
    • 2014
  • Background A blow-out fracture is one of the most common facial injuries in midface trauma. Orbital wall reconstruction is extremely important because it can cause various functional and aesthetic sequelae. Although many materials are available, there are no uniformly accepted guidelines regarding material selection for orbital wall reconstruction. Methods From January 2007 to August 2012, a total of 78 patients with blow-out fractures were analyzed. 36 patients received absorbable mesh plates, and 42 patients received titanium-dynamic mesh plates. Both groups were retrospectively evaluated for therapeutic efficacy and safety according to the incidence of three different complications: enophthalmos, extraocular movement impairment, and diplopia. Results For all groups (inferior wall fracture group, medial wall fractrue group, and combined inferomedial wall fracture group), there were improvements in the incidence of each complication regardless of implant types. Moreover, a significant improvement of enophthalmos occurred for both types of implants in group 1 (inferior wall fracture group). However, we found no statistically significant differences of efficacy or complication rate in every groups between both implant types. Conclusions Both types of implants showed good results without significant differences in long-term follow up, even though we expected the higher recurrent enophthalmos rate in patients with absorbable plate. In conclusion, both types seem to be equally effective and safe for orbital wall reconstruction. In particular, both implant types significantly improve the incidence of enophthalmos in cases of inferior orbital wall fractures.

Flexor Tenorrhaphy Using Absorbable Suture Materials

  • Kang, Hyung Joo;Lee, Dong Chul;Kim, Jin Soo;Ki, Sae Hwi;Roh, Si Young;Yang, Jae Won
    • Archives of Plastic Surgery
    • /
    • v.39 no.4
    • /
    • pp.397-403
    • /
    • 2012
  • Background Nonabsorbable sutures are favorable for repairing flexor tendons. However, absorbable sutures have performed favorably in an animal model. Methods Two-strand sutures using the interlocking modified Kessler method with polydioxanone absorbable sutures 4-0 were used to repair completely ruptured flexor tendons in 55 fingers from 41 consecutive patients. The medical records of average 42 follow up weeks were analyzed retrospectively. The data analyzed using the chi-squared test, and Fisher's exact test was used for postoperative complications. The results were compared with those of other studies. Results Among the index, middle, ring, and little fingers were injured in 9, 17, 16, and 13 fingers, respectively. The injury levels varied from zone 1 to 5. Of the 55 digits in our study, there were 26 (47%) isolated flexor digitorum profundus (FDP) injuries and 29 (53%) combined FDP and with flexor digitorum superficialis injuries. Pulley repair was also conducted. Concomitant injuries of blood vessels and nerves were found in 17 patients (23 fingers); nerve injuries occurred in 5 patients (10 fingers). Two patients had ruptures (3.6%), and one patient had two adhesions (3.6%). Using the original Strickland criteria, all the patients were assessed to be excellent or good. Also, fibrosis and long-term foreign body tissue reactions such as stitch granuloma were less likely occurred in our study. Compared to the Cullen's report that used nonabsorbable sutures, there was no significant difference in the rupture or adhesion rates. Conclusions Therefore, this study suggests that appropriate absorbable core sutures can be used safely for flexor tendon repairs.

Clinical Results of Arthroscopic Bankart Repair with Absorbable Knot-tying and Absorbable Knotless Suture Anchors (견관절 전방 불안정증에서 관절경적 방카트르 봉합술 시 흡수성 매듭 봉합 나사못과 흡수성 비 매듭 봉합 나사못을 이용한 임상적 치료결과 비교)

  • Kim, Seong-Jun;Lu, Yao-Jia;Oh, Kyung-Soo;Bahng, Seung-Chul;Park, Jin-Young
    • Journal of the Korean Arthroscopy Society
    • /
    • v.17 no.1
    • /
    • pp.50-55
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the clinical results of absorbable knot-tying and absorbable knotless suture anchors in arthroscopic Bankart repair. Materials and Methods: This study compared the patients who underwent arthroscopic Bankart repairs using absorbable knottying suture anchors (59 patients: KT Group), and absorbable knotless suture anchors (52 patients: KL Group). Preoperative and postoperative evaluations were performed by Rowe scores, patient satisfaction score, visual analogue scale (VAS), American shoulder and elbow surgeons (ASES) score, range of motion (ROM), and re-dislocation rate. Results: Postoperative VAS, Rowe scores, ASES score were significantly not different between the 2 groups (VAS: p=0.250, Rowe score: p=0.412, ASES: p=0.052). Mean postoperative VAS was 0.5 in KT Group and 0.8 in KL Group (p=0.250), and limited ROM was noted only in one patient in KL Group. Mean Rowe score was 94.3 in KT Group and 96.3 in KL Group (p=0.412), and mean ASES score was 97.3 in KT Group and 94.0 in KL Group (p=0.052). Re-dislocation rate were no different between the 2 groups. Conclusion: There were no differences in clinical outcomes and re-dislocation rate between Knot-Tying and Knotless repairs.

  • PDF

POSTOPERATIVE STABILITY OF FIXATION WITH ABSORBABLES IN SIMULTANEOUS MAXILLOMANDIBULAR ORTHOGNATHIC SURGERY (상하악 동시 악교정수술에서 흡수성 고정판을 이용한 골편고정시 술후 안정성에 대한 연구)

  • Park, Jung-Min;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.126-131
    • /
    • 2010
  • Objectives: This study is aimed to determine any differences in the postoperative stability between absorbable and titanium plate systems for fixation in orthognathic surgery with simultaneous maxillomandibular procedures especially including maxillary posterior impaction and advancement. Study Design: Forty patients with dentofacial deformities were randomly assigned into titanium (4 males and 6 females) and absorbable (17 males and 13 females) fixation group. All patients had undergone surgical alterations of maxilla with posterior impaction and advancement. A comparison study of the change in the maxillary position after the simultaneous surgery was performed with 1-day, 6-months postoperative lateral cephalograms compared to preoperative lateral cephalogram by tracing. Wilcoxon rank sum test was used for statistical analysis. Result: The position of the maxilla was stable after surgery and was not changed significantly from 1 day to 6 month after the simultaneous maxillomandibular surgery both in the experimental (absorbable plates) and control (titanium plates). Conclusion: This study suggests that application of absorable plating system in the fixation of maxillary segment in the simultaneous maxillomandibular procedures, leads to a predictable short-term postoperative skeletal stability comparable to the titanium plating system. Long term follow-up and further studies will be needed.

Pretibial Cyst after Anterior Cruciate Ligament Reconstruction Using bio-absorbable interference screw fixation - A Case Report - (생체분해성간섭나사를 이용한 전방십자인대 재건술 후 발생한 경골 근위부 낭종-증례 보고-)

  • Chun, Keun Churl;Kim, Jung Woo;Kim, Tae Kuyn;Chun, Churl Hong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Pretibial cyst formation is a rare complication after anterior cruciate ligament (ACL) reconstruction and there are only few cases reported. Pretibial cyst can be caused by variable reasons. Foreign body reaction due to breakdown of bio-absorbable screw for fixation, graft necrosis at tibial site, joint fluid leakage to tunnel and incomplete incorporation of graft to bony tunnel. The authors experienced one case of massive pretibial cyst after arthroscopic ACL reconstruction using bio-absorbable interference screw in 38-year-old male patient. Thus, authors report this rare case with literature view.

  • PDF

Radioopacity of Absorbable Plate containing Hydroxyapatite and Gold(Au); A Preliminary Report (Hydroxyapatite와 금(Au)이 혼합된 흡수성 고정판의 방사선비투과성; 예비 실험)

  • Kim, Yong Ha;Nam, Hyun Jae;Lee, Joon Ho;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.419-422
    • /
    • 2008
  • Purpose: Absorbable bone fixation materials for operation of facial bone fracture are composed of poly- lactic acid(PLA) & poly-glycolic acid(PGA). These materials are absorbed after facial bone healing period. Therefore, these materials are harmless in human body. But because of it's radioopacity, the number and the location of the materials are not checked in follow-up X-ray examination. We studied absorbable bone fixation materials checked radiological examination. So, we made the absorbable plate composed of PLA, Hydroxyapatite (HA) and Gold(Au). Methods: Plate 1 was consisted of pure PLA. Plate 2 was consisted of PLA(50%) and HA(50%). Plate 3 - 7 were consisted of PLA(50%), and variable composition of HA & Au. The ratio of Au was as following. From the plate 3 to plate 7, the Au ratio was 1%, 5%, 10%, 17%, and 25%, respectively. Total 3 examinations were used-naked eye examination, simple X-ray examination, and Haunsfield unit of plate in CT examination. Results: Naked eye examination found out that the color of plate 1 was most white. As the Au ratio increases, the color of plate was getting close to khaki color. the radioopacity of plate 2 was similar cortical bone of face in simple X-ray. The Haunsfield unit of cortical bone of face was 1000 HU. Haunsfield unit of titanium plate was 2900 HU. Haunsfield unit of plate 1 through plate 7 were -242, 1489, 1776, 3052, 3092, 3095, and 3095, respectively. Conclusion: Radioopacity of plate 2 was similar to cortical bone of face. In CT examination, Hanusfield unit of plate 2 was similar to Hanusfield unit of cortical bone of face. Hanusfield unit of plate 4 - 7 were similar to Hanusfield unit of titanium plate. So to trace bone fixation materials after facial bone surgery, the best ratio of Au is about 1 - 5%. If this study is applied to facial bone surgery, radiologic follow up would be easy after facial bone surgery.