• Title/Summary/Keyword: Absorbable

Search Result 259, Processing Time 0.026 seconds

Risk Assessment of Human Exposure to Methidathion during Harvest of Cucumber in Green House

  • Byoun Ji-Youn;Choi Hoon;Moon Joon-Kwan;Park Hee-Won;Liu Kwang-Hyeon;Ihm Yang-Bin;Park Byeoung-Soo;Kim Jeong-Han
    • Toxicological Research
    • /
    • v.21 no.4
    • /
    • pp.297-301
    • /
    • 2005
  • Farmers are generally expressed to pesticides through mixing loding, application activity and harvesting of crop after application of pesticides. The present work investigated the exposure and risk of furathiocarb to workers when harvesting of cucumber was carried out in green house after application of furathiocarb EC. Glove was used for the hand exposure assessment, socks for foot and dermal patches for the other parts of body. Personal air monitor equipped with a XAD-2 resin was used for the respiratory exposure assessment. During the harvest of cucumber in green house, the initial rate of potential dermal exposure (Day 1) for methidathion was 1.3 mg/hr. The major exposure parts were hand $(78\~83\%),\;thigh\;(5\~7\%)$ and arms $(6\~9\%)$ during 3 days' harvest. No exposure was detected from the respiratory monitoring. For risk assessment, the potential dermal exposure (PDE), the absorbable quantity of exposure (AQE) and the margin of safety (MOS) and margin of exposure (MOE) were calculated. In risk assessment of harvester exposure for 7days, all MOS was > 1 and MOE was > 100 indicating that possibility of risk was little.

Removal of Microfat Graft in Lower Eyelid with Transconjunctival Approach (결막절개를 제거통한 아래 눈꺼풀 부위의 미세자가지방이식편의)

  • Shin, Jong-In;Chang, Jung-Woo;Kim, Chang-Yeon;Kim, Youn-Hwan
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.48-52
    • /
    • 2011
  • Purpose: Microfat graft is a common procedure for correcting tear trough deformity and dark circle. Because the tissue in this area is very thin, the grafted fat, sometimes, induces palpable lumps and uneven skin contour. When it happens, the surgical removal of the grafted fat is often needed. The authors made attempt of transconjunctival approach for removal, and this made infraorbital fat repositioning possible at the same time. Methods: 15 female patients with history of microfat graft on lower eyelid, got operation for the grafted fat removal with transconjunctival approach from April of 2009 to July of 2010. The dissection was performed in accordance with infraorbital fat repositioning surgery. Through the transconjunctival incision, knotted fat on orbital septum and orbicularis oculi muscle was removed without damage on skin. After grafted fat removal, subperiosteal space was made 1~2 mm below the inferior orbital rim by elevating periosteum. With preserving orbital septum, infraorbital fat was repositioned and anchored to subperiosteal space. Finally, transconjunctival incision was closed with absorbable suture material. Results: 14 patients in the study showed satisfactory results. The problems like uneven skin contour and knotted fat mass, were all solved. In only one patient, incomplete correction was observed, as bulging on her right lower eyelid still remained. One patient complained of transient numbness on lower eyelid, but there was no specific complication other than this. Conclusion: The authors attempted the method of transconjunctival approach to remove former grafted fat in lower eyelid and reposition infraorbital fat simultaneously. Since the study brought great results, the method would be helpful to patients and surgeons.

Vascularized Bipedicled Pericranial Flaps for Reconstruction of Chronic Scalp Ulcer Occurring after Cranioplasty

  • Yoon, Seok Ho;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.341-347
    • /
    • 2013
  • Background Intractable chronic scalp ulcers with cranial bone exposure can occur along the incision after cranioplasty, posing challenges for clinicians. They occur as a result of severe scarring, poor blood circulation of the scalp, and focal osteomyelitis. We successfully repaired these scalp ulcers using a vascularized bipedicled pericranial flap after complete debridement. Methods Six patients who underwent cranioplasty had chronic ulcers where the cranial bone, with or without the metal plate, was exposed along the incision line. After completely excising the ulcer and the adjacent scar tissue, subgaleal dissection was performed. We removed the osteomyelitic calvarial bone, the exposed metal plate, and granulation tissue. A bipedicled pericranial flap was elevated to cover the defect between the bone graft or prosthesis and the normal cranial bone. It was transposed to the defect site and fixed using an absorbable suture. Scalp flaps were bilaterally advanced after relaxation incisions on the galea, and were closed without tension. Results All the surgical wounds were completely healed with an improved aesthetic outcome, and there were no notable complications during a mean follow-up period of seven months. Conclusions A bipedicled pericranial flap is vascularized, prompting wound healing without donor site morbidity. This may be an effective modality for treating chronic scalp ulcer accompanied by the exposure of the cranial bone after cranioplasty.

The Merits of Mannitol in the Repair of Orbital Blowout Fracture

  • Shin, Kyung Jin;Lee, Dong Geun;Park, Hyun Min;Choi, Mi Young;Bae, Jin Ho;Lee, Eui Tae
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.721-727
    • /
    • 2013
  • Background One of the main concerns in orbital blowout fracture repair is a narrow operation field, due mainly to the innate complex three dimensions of the orbit; however, a deep location and extensive area of the fracture and soft tissue edema can also cause concern. Swelling of the orbital contents progresses as the operation continues. Mannitol has been used empirically in glaucoma, cerebral hemorrhage, and orbital compartment syndrome for decompression. The authors adopted mannitol for the control of intraorbital edema and pressure in orbital blowout fracture repair. Methods This prospective study included 108 consecutive patients who were treated for a pure blowout fracture from January 2007 to October 2012. For group I, mannitol was administered during the operation. Under general anesthesia, all patients underwent surgery by open reduction and insertion of an absorbable mesh implant. The authors compared postoperative complications, the reoperation rate, operation time, and surgical field improvement between the two groups. Results In patients who received intraoperative administration of mannitol, the reoperation rate and operation time were decreased; however, the difference was not statistically significant. The total postoperative complication rates did not differ. Panel assessment for the intraoperative surgical field video recordings showed significantly improved vision in group I. Conclusions For six years, mannitol proved itself an effective, reliable, and safe adjunctive drug in the repair of orbital blowout fractures. With its rapid onset and short duration of action, mannitol could be one of the best methods for obtaining a wider surgical field in blowout fracture defects.

A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

  • Bektas, Cem Inan;Kankaya, Yuksel;Ozer, Kadri;Baris, Ruser;Aslan, Ozlem Colak;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.711-714
    • /
    • 2013
  • Background The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds. Methods Between March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm). First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion. Results The mean follow-up was 7 months (range, 2-10 months) in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent. Conclusions In our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

Comparative study of wound healing in canine stomach with CO2 laser and scalpel incisions (CO2 레이저와 scalpel을 이용한 위 절개 시 개에서의 창상 치유 평가)

  • Lee, Jae-Yeon;Hwang, You-Sun;Kim, Han-Kyul;Choi, Hyun-Suk;Jeong, Seong-Mok;Cho, Sung-Whan;Park, Chang-Sik;Kim, Myung-Cheol
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • The objective of this study was to compare wound healing in stomach with $CO_{2}$ laser and scalpel incision by measuring the extent of bleeding, the ease of gastric incision, incision time, degree of adhesion and wound healing degree in dogs. Sixteen healthy dogs were used. Two symmetrical incisions were made in ventral aspect of the stomach between the greater and lesser curvatures were made with scalpel and 0.2 mm spot diameter $CO_{2}$ laser (8W, continuous wave) in sixteen dogs. And then each wound was closed with absorbable suture in a two-layer inverting seromuscular pattern. At 3, 7, 14 and 21 days after initial wounding, each wound was taken for histological observation. On surgery, the extent of bleeding, the ease of incision and incision time showed significant differences between the groups. The $CO_{2}$ laser provided better hemostasis (p < 0.05) and smaller postoperative adhesion compared with the scalpel. However, the scalpel produced faster speed of incision and was easier to handle than the $CO_{2}$ laser (p < 0.05). Although there was no considerable difference between the two groups in histological observation, necrosis and calcium deposit tended to be larger in the $CO_{2}$ laser than in the scalpel.

Stepwise verification of bone regeneration using recombinant human bone morphogenetic protein-2 in rat fibula model

  • Nam, Jung-Woo;Kim, Hyung-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.6
    • /
    • pp.373-387
    • /
    • 2017
  • Objectives: The purpose of this study was to introduce our three experiments on bone morphogenetic protein (BMP) and its carriers performed using the critical sized segmental defect (CSD) model in rat fibula and to investigate development of animal models and carriers for more effective bone regeneration. Materials and Methods: For the experiments, 14, 16, and 24 rats with CSDs on both fibulae were used in Experiments 1, 2, and 3, respectively. BMP-2 with absorbable collagen sponge (ACS) (Experiments 1 and 2), autoclaved autogenous bone (AAB) and fibrin glue (FG) (Experiment 3), and xenogenic bone (Experiment 2) were used in the experimental groups. Radiographic and histomorphological evaluations were performed during the follow-up period of each experiment. Results: Significant new bone formation was commonly observed in all experimental groups using BMP-2 compared to control and xenograft (porcine bone) groups. Although there was some difference based on BMP carrier, regenerated bone volume was typically reduced by remodeling after initially forming excessive bone. Conclusion: BMP-2 demonstrates excellent ability for bone regeneration because of its osteoinductivity, but efficacy can be significantly different depending on its delivery system. ACS and FG showed relatively good bone regeneration capacity, satisfying the essential conditions of localization and release-control when used as BMP carriers. AAB could not provide release-control as a BMP carrier, but its space-maintenance role was remarkable. Carriers and scaffolds that can provide sufficient support to the BMP/carrier complex are necessary for large bone defects, and AAB is thought to be able to act as an effective scaffold. The CSD model of rat fibula is simple and useful for initial estimate of bone regeneration by agents including BMPs.

Iron Nutritional Status of Female Students in Kangnung National University (강릉대 일부 여대생의 철분영양상태에 관한 연구)

  • 이규희;김은경;김미경
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.1
    • /
    • pp.23-32
    • /
    • 1997
  • To evaluate iron nutritional status of female college students, fasting blood samples were taken from 76 female students of Kangnung National University. Hemoglobin(Hb), hematocrit(Hct), serum iron(Fe), total iron binding capacity(TIBC) and serum ferritin concentrations were measured and transferrin saturation was calculated. Mean values for Hb, Hct, Fe, TIBC, TS and serum freeitin were 13.64$\pm$1.42g/dl, 40.99$\pm$4.31%, 103.0$\pm$33.3$\mu\textrm{g}$/이, 395.3$\pm$9.07$\mu\textrm{g}$/dl, 26.58$\pm$9.07$\%$and 26.76$\pm$17.5ng/ml, respectively. Prevalence of iron deficiency greatly varied by indices from 6.8% when judged by Hct to 26.0$\%$ by serum ferritin concentration. The Hb concentration was positively correlated with hematocrit (r=0.5402), serum iron(r=0.2819) and transferrin saturation(r=0.2777)(p<0.05). on the other hand, serum ferritin concentration showed significantly negative correlation with TIBC(r=-0.3196). Two-day dietary intake records were collected from subjects to estimate mean daily iron intake and bioavailability of dietary iron. Mean daily intake of iron was 13.15mg and heme iron intake was 0.83mg which was 6.4% of total iron intake. Total absorbable iron calculated by the method of Monsen was 1.27mg and bioavailability of dietary iron was 9.6%. In the light of high prevalence of iron deficiency based of serum ferritin concentration and low bioavailability of iron in the diet, guidelines about diet should be made to increase the content and bioavailability of iron in the diet if female college students.

  • PDF

The Effect of a Shock-Absorbable Polymer(Chitosan) on the Initial Stability and Dynamic Behavior of Dental Implant (충격흡수용 고분자재료의 이용이 Implant 초기안정성과 동적거동에 미치는 영향)

  • Joo, W.;Choi, K.;Kwon, I.C.;Choi, J.B.;Moon, H.J.;Shin, J.W.;Lee, Y.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.337-342
    • /
    • 1997
  • Dental implant has been increasingly used to recover the masticatory unction of tooth. It has been well known that the success of dental implant is heavily dependent on initial stability and long-term osseointegration due to optimal stress distribution in the surrounding bones. The role of periodontal ligament, removed during operation, is to absorb impact force and to distribute them to alveolar bone. or this reason, the study for artificial periodontal ligament has become an important issue in this field. In this study, chitosan was coated on dental implant or the purpose of replacing the role of intact periodontal ligament. The results by experiment and FEM analysis showed : I) Initial stability of dental implant was significantly increased(35%) when the implant was coated with chitosan. II) The coated implant showed higher impact absorption, more even stress distribution and lower stress magnitude under impact force than uncoated implant. Accordingly, the micro-fracture of the surrounding bones due to impact force would be lessened by chitosan coating on dental implant.

  • PDF

Forehead Reconstruction with Hydroxyapatite Cement(MimixTM) and the Check Framework (Hydroxyapatite Cement(MimixTM)와 격자틀을 이용한 전두부 재건술)

  • Cho, Hyun Woo;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.219-222
    • /
    • 2008
  • Purpose: The purpose of this study is to develop hydroxyapatite cement simplified procedures for reconstruction of craniofacial deformities. Due to its expense and characteristics of quick hardening time, it may be inappropriate for forehead reconstruction or augmentation. Therefore we hear by introduce a more precise, easy and cheap method. The authors report forehead reconstruction with hydroxyapatite cement for a patient who suffered from craniofacial deformity. Methods: Case report and literature review. Results: A 35 year old man came to us with forehead and temporal area depression. He had a history of brain operations due to traumatic epidural hematoma. A physical exam showed an evidence of right side forehead weakness sign. Authors made RP model of his skull and applied check framework with Kirschner's wires for measuring accurate volume and contour on the depressed right side forehead area on the RP model. After complete exposure of defect area by bicoronary insicion, absorbable plate which applied on skull area was removed. Using three Kirschner's wires, authors made check framework on the right forehead lively and fixed with 2-hole miniplates on the boundary of the defect. After checking asymmetry, hydroxyapatite was applied on check shape framework just above Kirschner's wire. After removing Kirschner's wire, we corrected minimal unbalance and contour with bur. Conclusion: Check framework with Kirschner's wire was very convenient and cost saving methods for forehead reconstruction with hydroxyapatite cement.