• Title/Summary/Keyword: Abrasion test

Search Result 376, Processing Time 0.027 seconds

A study on properties and synthesis of polyurethane compound formed hard segments by polyether polyol for lamb skin coat (Lamb skin 코팅용 polyether polyol을 이용한 hard segment를 형성하는 polyurethane compound의 합성 및 물성에 관한 연구)

  • Lee, Joo-Youb;Nam, Sang-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.296-304
    • /
    • 2014
  • For this research, prepared polyurethane dispersion of hard segment type and polyethylene emulsion wax. Use these resin, this article has been analyzed about mechanical properties variation by increasing amount of polyethylene emulsion wax on Lam skin leather and dried film. According to measure data for solvent resistance, PUD had good property. As known in the results, increase of polyethylene wax constant did not influence to big variation of hybrid resin properties. As test of tensile strength, PUD had good tensile characteristic($1.235kg_f/mm^2$) and PUD-EW4 had lowest tensile characteristic($1.022kg_f/mm^2$). As same as tensile characteristic, abrasion test determined PUD(52.225 mg.loss) had highest properties. In elongation case, PUD showed 698 % modulus which was best properties in this experiment.

Mechanical properties of zirconia after different surface treatments and repeated firings

  • Subasi, Meryem Gulce;Demir, Necla;Kara, Ozlem;Ozturk, A. Nilgun;Ozel, Faruk
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.462-467
    • /
    • 2014
  • PURPOSE. This study investigated the influence of surface conditioning procedures and repeated firings on monoclinic content and strength of zirconia before cementation. MATERIALS AND METHODS. Sintered bar-shaped zirconia specimens were subjected to no surface treatment (control), air abrasion, or grinding (n=21). Their roughness was evaluated using a profilometer, and microscope analysis was performed on one specimen of each group. Then, 2 or 10 repeated firings (n=10) were executed, the monoclinic content of specimens was analyzed by X-ray diffraction, and a three-point flexural strength test was performed. Surface roughness values were compared using one-way analysis of variance (ANOVA) and Tukey honestly significant difference (HSD) tests, the monoclinic content values were tested using Kruskal-Wallis and Mann-Whitney U tests, and the flexural strength values were tested using two-way ANOVA and Tukey HSD tests (P=.05). Spearman's correlation test was performed to define relationships among measured parameters. RESULTS. Surface-treated specimens were rougher than untreated specimens and had a higher monoclinic content (P<.005), and the relationship between roughness and monoclinic content was significant (P<.000). Neither surface treatment nor firing significantly affected the flexural strength, but Weibull analysis showed that for the air-abraded samples the characteristic strength was significantly lower after the $10^{th}$ firing than after the $2^{nd}$ firing. CONCLUSION. After firing, a negligible amount of monoclinic content remained on the zirconia surfaces, and rougher surfaces had higher monoclinic contents than untreated surfaces. Multiple firings could be performed if necessary, but the fracture probability could increase after multiple firings for rougher surfaces.

A Study of the Purchasing Traits and the Wearing Satisfaction of Ski Wear (스키웨어의 구매와 착용만족도에 관한 조사연구)

  • Kim, Soon-Boon
    • Fashion & Textile Research Journal
    • /
    • v.8 no.3
    • /
    • pp.295-302
    • /
    • 2006
  • The purpose of this study was to research the purchasing traits and the wearing satisfaction of ski wears to provide the data needed to design ski wears to the related industries. This survey was performed during 2003's and 2004's winter with the 157 questionnaires containing 16 items of purchasing traits, 8 of design satisfaction, 12 of purchasing satisfaction and 13 of satisfaction of using convenience. The data were analysed with the frequency, the percentile, $X^2$-test, the average, the standard deviation and t-test through comparing with the groups of general people and experts, and the groups of male and female. The results were:1.The most preferred style was the two pieces style(88.5%), and then the loose style(61.1%), and the shoulder-wireless style(36.9%). 2.The imported brands were more preferred because of the design(44.1%). 3.The main place of purchasing was the ski wear speciality shop(48.4%), the main source of the merchandise information was the surrounding men(43.3%), the most significant consideration aspect when purchasing was the design(35.7%), and the rate of size perception was 51.6%. 4.The wearing satisfaction score(5) of ski wears were; the satisfaction of design was 3.24, the satisfaction of material 3.00, and the satisfaction of using convenience 3.07. 5.In the rate of design satisfaction, the female(3.10) showed higher than the male(3.35) (p<.05). 6.In the satisfaction of material, 'the discoloration'(2.37), 'the abrasion'(2.75), 'the sense of volume'(2.76) and 'the sense of touch' showed dissatisfaction. 7.In the satisfaction of using convenience, 'the pollution by lifting ticket'(2.36)was showed most dissatisfaction.

Experimental Investigation on the Non-linearity of Nitrile Butadiene Rubber (Nitrile Butadiene Rubber의 비선형성에 대한 실험적 연구)

  • Yoo, Myung-Ho;Lee, Taek-Sung;Do, Je-Sung;Kwon, Jong-Ho
    • Elastomers and Composites
    • /
    • v.42 no.3
    • /
    • pp.159-167
    • /
    • 2007
  • Hydraulic actuators are used widely for industrial machinery. The seal made from elastomer is used as a core part of the actuator, NBR(nitrile butadiene rubber) materials with high quality of oil resistance and abrasion resistance is used widely, requiring excellent characteristic of sealing. According to applied circumstances, the actuators for industrial machinery are used under different temperature situations. In this study, three different kinds of NBR, which is Hs70, 80, 90 are determined as one of hydraulic materials. An experimental investigation is performed to confirm the non-linearity under different temperature ($-10^{\circ}C,\;20^{\circ}C,\;80^{\circ}C,\;100^{\circ}C$) situation, material constants for finite element analysis and plastic deformation in accordance with Load-unload.

Effect of Nickel Content on Corrosion Resistance and Machinability of Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V-xNi Cast Iron (Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V-xNi 주철의 내식성 및 피삭성에 미치는 Ni의 영향)

  • Kim, Ki-Bin;Jung, Sung-Sik;Baek, Min-Sook;Yoon, Dong Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.576-584
    • /
    • 2020
  • The extruder screw material is mainly SKD11, but the recent development of synthetic resins have increased the occurrence of chemical corrosion and wear. To solve this issue, high chromium cast iron is needed because of its good abrasion resistance and corrosion resistance, but its use is avoided because of its poor machinability. In this study, to improve the machinability of high chrome cast iron, 0, 0.5, 1.0, 1.5% of nickel, which has excellent workability, was added to high chromium cast iron with a composition of Fe-23Cr-2.5C-1.2Si-1.08Mn-0.48Mo-0.3V, and annealed after casting. Subsequently, the effect of nickel on the machinability and corrosion resistance was analyzed using a turning test and coin polarization test, and compared with SKD11. After casting using a high-frequency vacuum induction furnace, the annealing treatment was performed at 750 ℃ for five hours and then reheated at 1100 ℃ for five hours. A turning test after annealing at 750 ℃ showed that the machinability was improved remarkably when the nickel content was over 1.0%. In the potentiodynamic polarization test in a 5% NaCl solution, the corrosion resistance decreased with increasing nickel content in the as-cast and annealing treatment. On the other hand, after reheating, the corrosion resistance was best with a 1.5% nickel content.

Effect of mechanical surface treatment on the fracture resistance and interfacial bonding failure of Y-TZP zirconia (Y-TZP zirconia의 기계적 표면처리가 파절저항과 접착계면 실패에 미치는 영향)

  • Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2014
  • Purpose: Surface damage and bonding strength difference after micromechanical treatment of zirconia surface are to be studied yet. The aim of this study was to evaluate the difference of fracture resistance and bonding strength between more surface-damaged group from higher air-blasting particle size and pressure, and less damaged group. Materials and Methods: Disk shape zirconia ($LAVA^{TM}$) was sintered and air-blasted with $30{\mu}m$ particle size (Cojet), under 2.8 bar for 15 seconds, $110{\mu}m$ particle size (Rocatec), under 2.8 bar for 15 seconds, and $110{\mu}m$ particle size (Rocatec), under 3.8 bar for 30 seconds respectively. Biaxial flexure test and bonding failure load test were performed serially (n = 10 per group). For bonding test, specimens were bonded on the base material having similar modulus of elasticity of dentin with $200{\mu}m$-thick resin cement for tension of surface damage. Failure load of bonding was detected with acoustic emission (AE) sensor. Results: There were no significant differences both in the biaxial flexure test and bonding failure load test between groups (P > 0.05). Sub-surface cracks were all radial cracks except for two specimens. Conclusion: Within the limitations of no aging under monotonic load test, surface damage from higher air-blasting particle size and pressure was not significant. Evaluations of failure load with bonded zirconia disks was clinically relevant modality for surface damage and bonding strength, simultaneously.

Evaluation of shear-bond strength between different self-adhesive resin cements with phosphate monomer and zirconia ceramic before and after thermocycling (인산염계 기능성 단량체가 첨가된 수종의 자가 접착 레진시멘트와 지르코니아 세라믹 사이 열순환 전후 전단결합강도 비교)

  • Lee, Ji-Hun;Kim, Min-Kyung;Lee, Jung-Jin;Ahn, Seung-Geun;Park, Ju-Mi;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.318-324
    • /
    • 2015
  • Purpose: This study compared shear bond strengths of five self-adhesive cements with phosphate monomer to zirconium oxide ceramic with and without airborn particle abrasion. Materials and methods: One hundred zirconia samples were air-abraded ($50{\mu}mAl_2O_3$). One hundred composite resin cylinders were fabricated. Composite cylinders were bonded to the zirconia samples with either Permacem 2.0 (P), $Clearfil^{TM}$ SA Luting (C), $Multilink^{(R)}$ Speed (M), $RelyX^{TM}$ U200 Automix (R), G-Cem $LinkAce^{TM}$ (G). All bonded specimens were stored in distilled water ($37^{\circ}C$) for 24 h and half of them were additionally aged by thermocycling ($5^{\circ}C$, $55^{\circ}C$, 5,000 times). The bonded specimens were loaded in shear force until fracture (1 mm/min) by using Universal Testing Machine (Model 4201, Instron Co, Canton, MA, USA). The failure sites were inspected under field-emission scanning electron microscopy. The data was analyzed with ANOVA, Tukey HSD post-hoc test and paired samples t-test ($\alpha$=.05). Results: Before and after thermocycling, $Multilink^{(R)}$ Speed (M) revealed higher shear-bond strength than the other cements. G-Cem $LinkAce^{TM}$ (G) showed significantly lower bond strengths after thermocycling than before treatment (P<.05), but the other groups were not significantly different (P>.05). Conclusion: Most self-adhesive cements with phosphate monomer showed high shear bond strength with zirconia ceramic and weren't influenced by thermocycling, so they seem to valuable to zirconia ceramic bonding.

Comparison of shear bond strength according to various surface treatment methods of zirconia and resin cement types (지르코니아의 다양한 표면처리 방법과 레진시멘트 종류에 따른 전단결합강도 비교)

  • Bae, Ji-Hyeon;Bae, Gang-Ho;Park, Taeseok;Huh, Jung-Bo;Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.153-163
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the effects of four surface treatment methods to improve zirconia roughness and three types of resin cement on the shear bond strength (SBS). Materials and methods: A total of 120 zirconia blocks were randomly divided into four surface treatments: non-treatment (Control), airborne-particle abrasion (APA) with 50 ㎛ Al2O3 (APA50), APA with 125 ㎛ Al2O3 (APA125), and ZrO2 slurry (ZA). Three resin cements (Panavia F 2.0, Superbond C&B, and Variolink N) were applied to the surface-treated zirconia specimens. All specimens were subjected to SBS testing using a universal testing machine. The surface of the representative specimens of each group was observed by scanning electron microscope (SEM). SBS data were analyzed with oneway ANOVA, two-way ANOVA test and post-hoc Tukey HSD Test (α=.05). Results: In the surface treatment method, APA125, APA50, ZA, and Control showed high shear bond strength in order, but there was no significant difference between APA125 and APA50 (P>.05). Also, ZA showed significantly higher shear bond strength than Control (P<.05). In the resin cement type, Panavia F 2.0, Superbond C&B, and Variolink N showed significantly higher shear bond strength in order (P<.05). In SEM images, the zirconia surfaces of the APA50 and APA125 showed quite rough and irregular shapes, and the zirconia surface of the ZA was observed small irregular porosity and rough surfaces. Conclusion: APA and ZrO2 slurry were enhanced the surface roughness of zirconia, and Panavia F 2.0 containing MDP showed the highest shear bond strength with zirconia.

Loess(Yellow Soil) Finishing Materials Using Water-based Adhesive for Wooden Construction Indoor Wall (수성접착제를 이용한 목조주택 내벽용 황토 마감재의 물성 및 친환경성)

  • An, Jae-Yoon;Kim, Ki-Wook;Kim, Sumin;Oh, Jin-Kyoung;Kim, Hyun-Joong;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.100-107
    • /
    • 2007
  • People have spent lots of time inside building about 90% of these day. Industry has been developed rapidly after I960. Construction materials had changed from natural materials to chemical materials and confidentiality of building has been more higher than before by policy of saving energy. These have caused sick-building syndrome (SBS) for us. So people want environmental construction materials for their house. We designed a environmental loess (yellow soil) finishing material which was composed of loess, water, water-soluble resin, hardener and filler. The purposes of this study were that making an environmental loess finishing material with optimum ratio, evaluating the usability of loess finishing material for wall. Furthermore it was suitable for wall to evaluate mechanical properties that are impact test, cracking test, abrasion test and de-bonding test, environmental properties that were emission of VOCs, formaldehyde and far infrared radiation.

Evaluation of physical properties of polycarbonate temporary restoration materials (폴리카보네이트 임시수복재료의 물성 평가)

  • Kim, Gwang-Yun;Kwak, Young-Hun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.168-175
    • /
    • 2020
  • Purpose: The purpose is to test and evaluate the physical properties of commonly used temporary restoration materials and newly emerged materials. Materials and Methods: Four groups of polymer materials were evaluated: Polymethyl methacrylate (PMMA) 2 groups, Polyetheretherketone (PEEK), Polycarbonate. Four physical properties were tested: surface hardness, bending strength, abrasion resistance during wear, wear behavior. The 3-axis bending strength and Vickers hardness test were measured using a universal testing machines respectively. The microstructure was observed with a scanning electron microscope and weight comparison was evaluated after 100,000 chewing tests using a chewing simulator. Kruskal wallis test was performed to evaluate statistical significance. Results: The four groups showed the highest flexural strength and Vickers hardness of PEEK, followed by PC, PMMA-H, PMMA-T. Microstructure observation also showed the least surface roughness in the PEEK group, followed by PC, PMMA-H, PMMA-T. Conclusion: PC is considered to have sufficient mechanical properties that can be applied to the manufacture of temporary teeth. However, further studies, such as biocompatibility, are considered to be necessary for practical clinical applications.