• Title/Summary/Keyword: Abnormal condition

Search Result 709, Processing Time 0.036 seconds

Transient analysis of marine propulsion motor and shaft under abnormal conditions (이상상태 발생 시 선박용 추진전동기 및 추진축의 과도상태 해석)

  • Oh, Sae-Gin;Kim, Jong-Su;Kim, Seung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.34-38
    • /
    • 2016
  • Recently, electric propulsion systems are been increasingly used in large cruise ships and merchant vessels. When abnormal electrical conditions occur in the motor of an electric propulsion ship, they can cause serious damage to the motor and propeller shaft. Research on abnormal conditions of propulsion motors used in electric propulsion vessels and electric ships difficult to find. In this study, a mathematical model of the electric propulsion system is proposed to analyze transient phenomena that occur in the case of electric propulsion motor or propeller shaft malfunction. A synchronous motor was used in the MATLAB computer simulation of this study. In the event of electrical malfunction of the electric propulsion motor at rated operation, over current occurs in the condition of 1 phase ground, over torque occurs at 3 and 2 phases ground and over current and torque occur when exciting power fails at rated operation.

Development of algorithms for the home care of postpartum mothers and infants (산욕기 산모와 신생아의 가정간호 알고리즘 개발)

  • Bang, Kyung-Sook
    • Journal of Home Health Care Nursing
    • /
    • v.4
    • /
    • pp.65-75
    • /
    • 1997
  • The needs for the home care of postpartum mothers and their infants are increasing, but the quality control of home care nurses is not developed yet. The objective of this study is to develop assessment - intervention algorithms for the home care of postpartum mothers and their infants. We can use these algorithms when we assess the client's condition, and find appropriate nursing interventions. Also, these algorithms can offer guidelines for home care nurses, so that standardization of home care can be attained. Common problems for postpartum mothers are postpartum hemorrhage, abnormal vaginal discharge(endometritis), episiotomy pain, breast problems, breastfeeding difficulty, edema, urinary dysfunction and defecation difficulties. Also, commom problems for infants are abnormal body temperature, tarchycardia, respiratory problem, neonatal jaundice, cord problem, abnormal stool, breast feeding, and bathing. These algorithms can be used as a basis for the development of computerized infomation system for the home health care.

  • PDF

2 Cases of Pneumosinus Dilatans (기부비동 확장증(Pneumosinus dilatans) 2례)

  • Na, Young Cheon
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.1
    • /
    • pp.35-37
    • /
    • 2008
  • Pneumosinus Dilatans consists of an abnormal dilatation of the paranasal sinuses which contain air only and lined by normal mucosa. It is a rare condition, the etiology of which is unclear. A 16 year old male complained frontal bossing which developed slowly. Simple X-ray and CT showed abnormal distension of frontal sinus. Another 19 year old male complained slowly growing left cheek mass. Simple X-ray and CT showed abnormal distension of anteromedial wall of maxillary sinus. In view of the cosmetic appearance, operations were performed. Distended sinuses walls were removed and reconstructed using $Medpore^{(R)}$. I report 2 cases of pneumosinus dilatans which developed in frontal and maxillary sinuses and the literature reviewed.

Study of ZVS-PWM Series Resonant Converter with Active-Clamp Technique (액티브 클램프 기법을 이용한 영전압 스위칭 직렬 공진형 컨버터에 관한 연구)

  • Jeon, Hee-Cheol;Kim, Yong;Jung, Kye-Cheon;Kim, Pil-Soo;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2674-2677
    • /
    • 1999
  • Resonant converters have several salient features such as high efficiency and low noise. Therefore, ZVS-PWM controlled series resonant converter with active-clamp technique is presented. The combination of an active-clamp technique and resonant circuit makes it possible to control the output voltage of the resonant converter with PWM. This new resonant converter was implemented and has achieved a good controllability. In this paper, the normal load characteristics and abnormal voltage increase in the case of the light load are analyzed. As a result, it is clarified that the stray capacitance of the transformer is a cause of the abnormal voltage increase. Then, it is confirmed that the abnormal voltage increase is suppressed by decreasing the duty ratio. ZVS condition is analyzed. The maximum efficiency of 89% is obtained for the output of 10V and 5A.

  • PDF

The Fault Diagnosis Method of Diesel Engines Using a Statistical Analysis Method (통계적 분석기법을 이용한 디젤기관의 고장진단 방법에 관한 연구)

  • Kim, Young-Il;Oh, Hyun-Kyung;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.247-252
    • /
    • 2006
  • Almost ship monitoring systems are event driven alarm system which warn only when the measurement value is over or under set point. These kinds of system cannot warn until signal is growing to abnormal state that the signal is over or under the set point. therefore cannot play a role for preventive maintenance system. This paper proposes fault diagnosis method which is able to diagnose and forecast the fault from present operating condition by analyzing monitored signals with present ship monitoring system without any additional sensors. By analyzing the data with high correlation coefficient(CC), correlation level of interactive data can be defined. Knowledge base of abnormal detection can be built by referring level of CC(Fault Detection CC. FDCC) to detect abnormal data among monitored data from monitoring system and knowledge base of diagnosis built by referring CC among interactive data for related machine each other to diagnose fault part.

Measurement and Control of Abnormal Sound for Refrigerator (냉장고의 이상소음에 관한 사례연구)

  • 주재만;김중래;이동현
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.380-384
    • /
    • 2001
  • The household reftigerator's noise which is closely related with resident environment can hardly be evaluated its sound quality using the Korean Standards. Radiation characteristics of compressor noise consist of tonal noise in low frequency range and, or narrow band noise in high frequency range. In this study, measuring method for detecting the abnormal and low-level noise in high frequency band is presented, and control method for its reduction is proposed. After installing wall which is similar to living condition, we determined a major concerning frequency band of noise. It can be found the directivity of high frequency noise radiated from compressor by using experiment and analysis. According to isolation of noise transfer path, remarkable noise reduction is achieved.

  • PDF

The Fault Diagnosis Method of Diesel Engines Using a Statistical Analysis Method (통계적분석기법을 이용한 디젤기관의 고장진단 방법에 관한 연구)

  • Kim, Young-Il;Oh, Hyun-Gyeong;Cheon, Hang-Chun;Yu, Yung-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.281-286
    • /
    • 2005
  • Almost ship monitoring systems are event driven alarm system which warn only when the measurement value is over or under set point. These kinds of system cannot warn while signal is growing to abnormal state until the signal is over or under the set point and cannot play a role for preventive maintenance system. This paper proposes fault diagnosis method which is able to diagnose and forecast the fault from present operating condition by analyzing monitored signals with present ship monitoring system without additional sensors. By analyzing this data having high correlation coefficient(CC), correlation level of interactive data can be understood. Knowledge base of abnormal detection can be built by referring level of CC(Fault Detection CC, FDCC) to detect abnormal data among monitored data from monitoring system and knowledge base of diagnosis built by referring CC among interactive data for related machine each other to diagnose fault part.

  • PDF

A Study on the Detection and Diagnosis of the Abnormal Machining Process Using Current Signal (전류신호를 이용한 이상가공상태 검출ㆍ진단에 관한 연구)

  • 서한원;유기현;정진용;서남섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.212-216
    • /
    • 1996
  • Recently, with the development of NC and CNC machine tools and the high labor wage, the cutting process requires the high speed and automatic system which uses industrial robots and the flexible manufacturing system(FMS) that combines several machine tools. In this system, the whole system can be influenced by just one of the machin tools. So it needs to detect a problem and to solve it immediately In in-process state. The monitoring system through measuring the motor current with current sensor has been attracting the attention of lots of researchers view of its low cost and flexibility. By using the pattern discriminant with the detected three-phase-current signal, that is, $I_{RMS}$, a system which can monitor and analyze abnormal machining process condition of the workpiece during the machining will be able to be developed in this research.h.

  • PDF

Fouling Mitigation for Pressurized Membrane of Side-Stream MBR Process at Abnormal Operation Condition (가압식 분리막을 이용한 Side-Stream MBR 공정의 비정상 운전조건에서 막 오염 저감)

  • Ko, Byeong-Gon;Na, Ji-Hun;Nam, Duck-Hyun;Kang, Ki-Hoon;Lee, Chae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.323-328
    • /
    • 2016
  • Pressurized membrane used for side-stream MBR process requires fouling control strategy both for normal and abnormal operation conditions for stable operation of the facilities. In this study, $85m^3/day$ of pilot-scale side-stream MBR process was constructed for the evaluation of fouling mitigation by air bubble injection into the membrane module. In addition, fouling phenomena at abnormal operation conditions of low influent and/or loading rate were also investigated. Injection of air bubble was found to be effective in delaying transmembrane pressure (TMP) increase mainly due to scouring effect on the membrane surface, resulting in expanded filtration cycle at a high flux of $40L/m^2{\cdot}h$ (LMH). At abnormal operation condition, injection of PACl (53 mg/L as Al) into the bioreactor showed 19% reduction of TMP increase. However, inhibition of nitrifying bacteria by continuous PACl injection was observed from batch experiments. In contrast, injection of powdered activated carbon (PAC, 0.6 g/L) was able to maintain the initial TMP of $0.2kg/cm^2$ for 5 days at the abnormal conditions. It may have been caused from the adsorption of extracellular polymeric substances (EPS), which was known to be excessively released during growth inhibition condition and act as the major foulants in MBR operations.

A Study on the Wear Characteristics of Austempered Ductile Iron (오스템퍼링한 구상흑연주철의 마모특성에 미치는 기지조직의 영향에 관한 연구)

  • Kim, Yun-Bog;Kim, Chang-Gyu;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.10 no.3
    • /
    • pp.235-246
    • /
    • 1990
  • This study has been carried out to investigate into the rolling wear characteristics of austempered ductile iron under unlubricated dry rolling condition by Amsler type test with 9.09% sliding ratio. Wear amount is increased with increasing of ferrite and retained austenite and it has been found that the amount of rolling wear is decreased when the hardness of matrix are higher. The rolling life up to generation of abnormal condition is conspicusly increased and amount of rolling wear is increased asrolling revolutionis increased and wear of austempered ductile ironunder dry rolling condition. Matrix has been obtained to upper bainite, low bainite at heat treatment, obtained to bull`s eye structure at as cast. It has been found that the amount of rolling wear is decreased when the tensile strength of the casting are increased and then the rolling life up to generation of abnormal wear in conspicuously increased and amount of wear was intend to graphite content.

  • PDF