• 제목/요약/키워드: Abnormal condition

검색결과 704건 처리시간 0.028초

네온 램프용 전자식 안정기에 관한 연구 (A Study on the Electronic Ballast for Neon Lamp)

  • 강범석;김희준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.314-318
    • /
    • 1998
  • This paper discusses the development of electronic ballast for neon lamp as an application of a zero voltage switching high frequency inverter. Abnormal increase of secondary voltage due to grounded fault or partial damage of serial arranged loads is clarified and the protection circuit for this abnormal voltage increase is proposed. Also stable lighting condition for removing the unstable characteristics due to different load conditions is proposed.

  • PDF

단자(Terminal) 압착조건에 따른 파형의 고찰 (A study on waveforms with press conditions of Harness terminal)

  • 신영록;양윤석;김철한;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.172-175
    • /
    • 2000
  • The crimping connection is a permanent connection that maintains mechanical and electrical property for a long time by crimping two conductors. In this paper, we have done a basic study to decide normal or abnormal condition depending on crimping. Using PZT piezo-sensor, we have analyzed crimping waveforms according to the crimping height. And hence the normal or abnormal condition of crimping connections in real time could be decided by comparison of crimping waveforms in the cases of normal crimping, over crimping, under crimping and core omitting.

  • PDF

지식기반 퍼지 추론을 이용한 디젤기관 연소계통의 고장진단 시스템에 관한 연구 (A Study on the Fault Diagnosis System for Combustion System of Diesel Engines Using Knowledge Based Fuzzy Inference)

  • 유영호;천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권1호
    • /
    • pp.42-48
    • /
    • 2003
  • In general many engineers can diagnose the fault condition using the abnormal ones among data monitored from a diesel engine, but they don't need the system modelling or identification for the work. They check the abnormal data and the relationship and then catch the fault condition of the engine. This paper proposes the construction of a fault diagnosis engine through malfunction data gained from the data fault detection system of neural networks for diesel generator engine, and the rule inference method to induce the rule for fuzzy inference from the malfunction data of diesel engine like a site engineer with a fuzzy system. The proposed fault diagnosis system is constructed in the sense of the Malfunction Diagnosis Engine(MDE) and Hierarchy of Malfunction Hypotheses(HMH). The system is concerned with the rule reduction method of knowledge base for related data among the various interactive data.

Diagnosing the Condition of Air-conditioning Compressors by Analyzing the Waveform of the Raw AE Signal

  • Kim Jeon-Ha;Lee Gam-Gyu;Kang Ik-Soo;Kang Myung-Chang;Kim Jeong-Suk
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권3호
    • /
    • pp.14-17
    • /
    • 2006
  • To diagnosis abnormal compressor conditions in an air-conditioner, the acoustic emission (AE) signal, which is derived from wear condition, compressed air, and assembly error, was analyzed experimentally. Burst and continuous type AE signals resulted from metal contact and compressed air, and the raw AE signal of compressors was acquired in the production line. After extracting samples using waveforms, the Early Life Test (ELT) was conducted and the waveform was classified as normal or abnormal. Efficient parameters in the waveform pattern were investigated in time and frequency domains and a diagnosis algorithm for air-conditioners using Neural Network estimation is suggested.

스핀코터의 진동 평가를 통한 이상 검출 시스템 개발 (Fault Detection System Development for a Spin Coater Through Vibration Assessment)

  • 문준희;이봉구
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.47-54
    • /
    • 2009
  • Spin coaters are the essential instruments in micro-fabrication processes, which apply uniform thin films to flat substrates. In this research, a spin coater diagnosis system is developed to detect the abnormal operation of TFT-LCD process in real time. To facilitate the real-time data acquisition and analysis, the circular-buffered continuous data transfer and the short-time Fourier transform are applied to the fault diagnosis system. To determine whether the system condition is normal or not, a steady-state detection algorithm and a frequency spectrum comparison algorithm using confidence interval are newly devised. Since abnormal condition of a spin coater is rarely encountered, algorithm is tested on a CD-ROM drive and the developed program is verified by a function generator. Actual threshold values for the fault detection are tuned in a spin coater in process.

XLPE 특고압 전력케이블의 절연 진단 (Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable)

  • 변두균;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

삼심방증 치험 2례 (Cor Triatrium; A Classic Type and a Type Combibed with Atrial Septal Defect; Report of Two Cases)

  • 손제문
    • Journal of Chest Surgery
    • /
    • 제26권7호
    • /
    • pp.543-547
    • /
    • 1993
  • Cor triatriatum is a rare entity of congenital heart disease characterized by the presence of a fibrousmuscular diaphragm that subdivides the left atrium into a proximal or "accessory" chamber and a distal or "true" left atrial chamber. In the other hand, cor triatriatum is a variant of abnormal connection between the pulmonary vein and true left atrium which is separated from accessory left atrium receiving pulmonary venous blood flow by fibromuscular diaphragm. We experienced two cases of cor triatriatum. One of them was classical, and the other case was combined with atrial septal defect and all pulmonary veins were drained into the " common pulmonary venous chamber " which connected with right atrium and there was no direct communication between the accessory chamber and true left atrium. The abnormal diaphragms were excised and the atrial septal defect was repaired with pericardial patch in case II. The postoperative courses were not eventful and the patients were discharged with good result, and have been in good condition upto now.n good condition upto now.

  • PDF

Endoscopic features aiding the diagnosis of gastric mucosa-associated lymphoid tissue lymphoma

  • Park, Byung Sam;Lee, Si Hyung
    • Journal of Yeungnam Medical Science
    • /
    • 제36권2호
    • /
    • pp.85-91
    • /
    • 2019
  • The incidence of gastric mucosa-associated lymphoid tissue (MALT) lymphoma is increasing worldwide, but the diagnosis is difficult. Most patients are asymptomatic or complain of nonspecific gastrointestinal symptoms. As the endoscopic features of gastric MALT lymphoma are variable and nonspecific, the possibility of this condition may be overlooked during esophagogastroduodenoscopy, and it remain undiagnosed. Therefore, this condition needs to be considered when an abnormal mucosa is observed during this procedure. Biopsy performed during endoscopy is the primary diagnostic test, but false negative results are possible; large numbers of samples should be collected from both normal and abnormal mucosae. Endoscopic ultrasonography is useful to assess the depth of invasion and to predict the treatment response. After treatment, follow-up tests are required every 3 months until complete remission is achieved, and annually thereafter. Early diagnosis of gastric MALT lymphoma is difficult, and its diagnosis and follow-up require wide experience and competent endoscopic technique.

부정기적 발생 신체이상 모니터링 블랙박스 프로그램 구현 (Implementation of a Black-Box Program Monitoring Abnormal Body Reactions)

  • 김원진;윤광렬
    • 한국전자통신학회논문지
    • /
    • 제7권3호
    • /
    • pp.671-677
    • /
    • 2012
  • 수면 중에 부정기적으로 발생하는 인체 이상유형을 모니터링하기 위한 블랙박스 프로그램을 구현하였다. 인체 블랙박스 시스템은 생체 신호를 계측하는 센서와 알람, 전등, 네트워크 카메라와 같은 보조 장치 및 신호를 모니터링 하는 컴퓨터로 구성되어 있다. 신체 이상 증상의 원인을 정확하게 규명하기 위하여 PPG, EOG, EEG, 호흡센서, 온도센서, G-센서 및 마이크로폰과 같은 다양한 센서를 이용하였다. 이상 증상이 발생하면 시스템은 치료에 활용할 수 있는 정보를 제공하기 위해서 환자의 상태를 기록한다. 신체 이상유형을 감지하게 위하여 적절한 센서 위치를 선정한다. 측정 데이터의 유형별 정상 범위에 근거하여, 신체 이상유형을 구별하기 위한 신호 수준을 선정하였다. 이상 신호가 계측되면 전등 및 알람, 네트워크 카메라가 동시에 작동하고, 센서 신호 및 비디오 데이터가 저장된다.

개인별 이상신호 검출과 QRS 패턴 변화에 따른 조기심실수축 분류 (PVC Classification by Personalized Abnormal Signal Detection and QRS Pattern Variability)

  • 조익성;윤정오;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제18권7호
    • /
    • pp.1531-1539
    • /
    • 2014
  • 조기심실수축(PVC)은 가장 보편적인 부정맥으로 심실세동, 심실빈맥 등과 같은 위험한 상황을 유발할 수 있는 가능성을 가지고 있기 때문에 이의 조기 검출은 매우 중요하다. 하지만 ECG 신호의 개인 차이가 있음에도 불구하고, 일반적인 신호의 판단 규칙에 따라 진단을 수행함으로써 성능하락이 나타날 수 밖에 없다. 이러한 문제점을 극복하기 위해서는 개인에 따른 이상 신호를 검출한 후 다양한 QRS 패턴을 고려하여 PVC를 분류할 수 있는 알고리즘이 필요하다. 본 연구에서는 개인별 이상신호 검출과 QRS 패턴 변화에 따른 PVC 분류 기법을 제안한다. 이를 위해 전 처리 과정과 차감기법을 통해 R파를 검출하였으며, 개인별 이상신호를 검출하였다. 이후 QRS 패턴에 따른 QS 간격과 R파의 진폭 변화율에 따라 PVC를 분류하였다. 제안한 알고리즘의 이상 신호 검출 및 PVC 분류 성능을 평가하기 위해서 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, 이상 신호 검출률은 98.33%, PVC는 각각 94.46%의 평균 분류율을 나타내었다.