• Title/Summary/Keyword: Ablative technique

Search Result 14, Processing Time 0.017 seconds

Evaluation of Structural Performance for Filament Wound Composite Ablative Tubes (필라멘트와인딩된 복합재 내열튜브의 구조 성능 평가)

  • 윤성호;황태경;윤남균;문순일
    • Composites Research
    • /
    • v.15 no.1
    • /
    • pp.53-60
    • /
    • 2002
  • Composite ablative tubes required capabilities of ablative and structural characteristics were fabricated through filament winding technique and several experiments were conducted to evaluate the structural performance of composite ablative tubes. For this purpose, manufacturing procedures were briefly described and then resin digestion method was applied to measure the fiber volume fraction and the void content of composite ablative tubes. The configuration of tensile specimen fur composite ablative tubes with not losing the continuity of reinforced fibers was suggested by evaluating mechanical properties of several types of the specimen with different widths. Also, suitable processing variables for composite ablative tubes were determined by evaluating mechanical properties of several types of the specimen with different processing variables. In addition, acoustic emission signals were obtained during the proof test and could be applicable to study the crack initiation and the damage mode of composite ablative tubes. Finally, the structural reliability of composite ablative tubes could be verified to satisfy design requirements through the proof and burst tests.

Current Research Status of Irreversible Electroporation for Hollow Viscus Organ of Gastrointestinal Tract (위장관 비가역적 전기천공법의 연구 현황)

  • Keum, Bora;Choi, Hyuk Soon;Jeon, Han Jo
    • Journal of Digestive Cancer Research
    • /
    • v.8 no.1
    • /
    • pp.61-64
    • /
    • 2020
  • Ablative therapy has drawn attention for cancer treatment as minimally invasive therapy. Recently, irreversible electroporation which has a different concept from the existing ablation method has emerged. Although gastrointestinal tract cancer is commonly managed by ablation such as liver, pancreas cancer, hollow viscus cancer is extremely challenging for applying ablative therapy because of its high perforation risk. Therefore, several studies about hollow viscus irreversible electroporation will be introduced in this review regarding its pre-clinical relevance.

Mandibular Reconstruction with Free Fibular Flap and Dental Implant after Ablative Oral Cancer Surgery Using 3D RP Model: A Case Report

  • Kim, Duck-Hoon;Cha, Hyun-Suk;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.90-94
    • /
    • 2014
  • Reconstruction of the mandible after ablative oral cancer surgery requires esthetic and functional rehabilitation. Restoring facial symmetry and dentition need accurate preoperative surgical planning and meticulous surgical technique. Free fibular flap is most useful tools to reconstruct mandible because of its adequate length and height, simultaneous harvest of soft and hard tissues and placing dental implants. In this case report, recurred squamous cell carcinoma in the right mandible had been resected and free fibular flap was utilized for mandible reconstruction using 3D rapid prototype. Simulation surgery before dental implant placement has been performed for esthetic and functional prosthodontics.

Predictive factors of symptomatic radiation pneumonitis in primary and metastatic lung tumors treated with stereotactic ablative body radiotherapy

  • Kim, Kangpyo;Lee, Jeongshim;Cho, Yeona;Chung, Seung Yeun;Lee, Jason Joon Bock;Lee, Chang Geol;Cho, Jaeho
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.163-171
    • /
    • 2017
  • Purpose: Although stereotactic ablative body radiotherapy (SABR) is widely used therapeutic technique, predictive factors of radiation pneumonitis (RP) after SABR remain undefined. We aimed to investigate the predictive factors affecting RP in patients with primary or metastatic lung tumors who received SABR. Materials and Methods: From 2012 to 2015, we reviewed 59 patients with 72 primary or metastatic lung tumors treated with SABR, and performed analyses of clinical and dosimetric variables related to symptomatic RP. SABR was delivered as 45-60 Gy in 3-4 fractions, which were over 100 Gy in BED when the ${\alpha}/{\beta}$ value was assumed to be 10. Tumor volume and other various dose volume factors were analyzed using median value as a cutoff value. RP was graded per the Common Terminology Criteria for Adverse Events v4.03. Results: At the median follow-up period of 11 months, symptomatic RP was observed in 13 lesions (12 patients, 18.1%), including grade 2 RP in 11 lesions and grade 3 in 2 lesions. Patients with planning target volume (PTV) of ${\leq}14.35mL$ had significantly lower rates of symptomatic RP when compared to others (8.6% vs. 27%; p = 0.048). Rates of symptomatic RP in patients with internal gross tumor volume (iGTV) >4.21 mL were higher than with ${\leq}4.21mL$ (29.7% vs. 6.1%; p = 0.017). Conclusions: The incidence of symptomatic RP following treatment with SABR was acceptable with grade 2 RP being observed in most patients. iGTV over 4.21 mL and PTV of over 14.35 mL were significant predictive factors related to symptomatic RP.

APPLICATION OF RECONSTRUCTION PLATE USING SIMPLE CONDYLAR REPOSITIONING MINIPLATE AFTER SEGMENTAL RESECTION OF MANDIBLE (하악골 절제술후 간단한 과두재위치 소형금속판을 이용한 재건 금속판의 적용: 증례보고)

  • Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.3
    • /
    • pp.231-233
    • /
    • 2002
  • Temporary reconstruction of the mandibular continuity defect resulting from the ablative tumor surgery with a reconstruction plate can be used for the preservation of normal facial contour and oral function and for periodic follow up of recurrence. Reconstruction plates are adapted to the bone before the resection and provisionally fixated with some screws. Accurate contouring and adaptation are very important for the prevention of displacement of bony stumps and decubituous skin ulcer. However, if there is large expanding buccal tumor mass in mandible, it is very difficult or even impossible to contour the plate before resection. I, therefore, introduce the reconstruction plate application technique using a simple condylar repositioning miniplate after segmental mandibular resection.

A CLINICAL STUDY ON SUPERIORLY BASED PLATYSMA MYOCUTANEOUS CERVICAL FLAP FOR RECONSTRUCTION FOLLOWING INTRAORAL SOFT TISSUE CANCER SURGERY (구강내 연조직 암 절제후 상부기조 광경근 근피부 경부 피판을 이용한 구강내 재건에 관한 임상적 연구)

  • Park, Bong-Wook;Byun, June-Ho;Shin, Hee-Suk;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.83-91
    • /
    • 2008
  • The goal of reconstruction following ablative therapy for intraoral cancer is the restoration of form and function to permit a return to activities of daily life. Traditional reconstruction includes split thickness skin grafts, myocutaneous flaps and, more recently, various free flaps. Free flaps provide higher level of functional recovery relative to that seen with other techniques but require the complexity of the technique and microvascular anastomosis and thus, extended surgical time and occasionally a second team for harvesting. The platysma myocutaneous cervical flap is a possible alternative for intraoral reconstruction. It is thin and pliable like the tissue provided by the radial forearm free flap. It can be harvested with enough tissue to close most head and neck ablative defects. There is virtually no donor site morbidity involved. This study evaluated 7 patients affected by intraoral squamous cell carcinoma (SCC). All patients underwent the resection of intraoral SCC with neck dissection and subsequent intraoral reconstruction with the superiorly based platysma myocutaneous cervical flap. Flap-related complications occurred in 3 patients. Adjuvant radiation therapy was performed in 3 patients. Average follow-up was 24.1 months after surgery, with a range of 8 to 42 months. All patients presented self assessment of discomfort associated with intraoral recipient sites and cervical donor sites. However, the neck function measured by two-inclinometer technique was within the normal range during relatively long term follow-up period. Our study concluded that superiorly based platysma myocutaneous cervical flap is good alternative to free flaps, especially for relatively smaller defects and for the defects appropriate for the rotation arc of the flap.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

Improving the Residual Stress Characteristics of the Metal Surface by Nd:YAG Laser Shock Peening (Nd:YAG 레이저 충격 피닝에 의한 금속표면의 잔류응력 특성 개선)

  • Yang, Se-Young;Choi, Seong-Dae;Jun, Jea-Mok;Gong, Byeong-Chae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.4
    • /
    • pp.539-547
    • /
    • 2010
  • Laser shock peening is useful to improve fatigue characteristic of multiple number of metals and alloys. This process induces a compressive residual stress on the metal surface, and when tensile load is applied, growth of crack is delayed and which changes the characteristic of the metal surface. It is an innovative surface treatment technique for strengthening metals. Specimens of SM45C are used in this study. The effect of an inertial tamping layer on the residual stress field using laser shock peening setup and Nd:YAG laser power is evaluated. Residual stress distribution measured by X-ray diffraction. As a result of this study it can be presented that following condition of Nd:YAG laser power and inertial tamping layer parameters, compressive residual stress is generated on the surface of the SM45C. Results to experimental data indicate that laser shock peening has great potential as a means of improving the mechanical performance of the metal surface.

Magnetic Resonance-Guided Focused Ultrasound in Neurosurgery: Taking Lessons from the Past to Inform the Future

  • Jung, Na Young;Chang, Jin Woo
    • Journal of Korean Medical Science
    • /
    • v.33 no.44
    • /
    • pp.279.1-279.16
    • /
    • 2018
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is a new emerging neurosurgical procedure applied in a wide range of clinical fields. It can generate high-intensity energy at the focal zone in deep body areas without requiring incision of soft tissues. Although the effectiveness of the focused ultrasound technique had not been recognized because of the skull being a main barrier in the transmission of acoustic energy, the development of hemispheric distribution of ultrasound transducer phased arrays has solved this issue and enabled the performance of true transcranial procedures. Advanced imaging technologies such as magnetic resonance thermometry could enhance the safety of MRgFUS. The current clinical applications of MRgFUS in neurosurgery involve stereotactic ablative treatments for patients with essential tremor, Parkinson's disease, obsessive-compulsive disorder, major depressive disorder, or neuropathic pain. Other potential treatment candidates being examined in ongoing clinical trials include brain tumors, Alzheimer's disease, and epilepsy, based on MRgFUS abilities of thermal ablation and opening the blood-brain barrier. With the development of ultrasound technology to overcome the limitations, MRgFUS is gradually expanding the therapeutic field for intractable neurological disorders and serving as a trail for a promising future in noninvasive and safe neurosurgical care.

Endoscopic ultrasound-guided intervention for inaccessible papilla in advanced malignant hilar biliary obstruction

  • Partha Pal;Sundeep Lakhtakia
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.143-154
    • /
    • 2023
  • Advanced malignant hilar biliary obstruction (MHBO) with inaccessible papilla poses a significant challenge to endoscopists, as drainage of multiple liver segments may be warranted. Transpapillary drainage may not be feasible in patients with surgically altered anatomy, duodenal stenosis, prior duodenal self-expanding metal stent, and after initial transpapillary drainage, but require re-intervention for draining separated liver segments. Endoscopic ultrasound-guided biliary drainage (EUS-BD) and percutaneous trans-hepatic biliary drainage are the feasible options in this scenario. The major advantages of EUS-BD over percutaneous trans-hepatic biliary drainage include a reduction in patient discomfort and internal drainage away from the tumor, thus reducing the possibility of tissue or tumor ingrowth. With innovations, EUS-BD is helpful not only for bilateral communicating MHBO but also for non-communicating systems with bridging hilar stents or isolated right intra-hepatic duct drainage by hepatico-duodenostomy. EUS-guided multi-stent drainage with specially designed cannulas and guidewires has become a reality. A combined approach with endoscopic retrograde cholangiopancreatography for re-intervention, interventional radiology, and intraductal tumor ablative therapies has been reported. Stent migration and bile leakage can be minimized with proper stent selection and technique, and stent blocks can be managed with EUS-guided interventions in a majority of cases. Future comparative studies are required to establish the role of EUS-guided interventions in MHBO as rescue or primary therapy.