• Title/Summary/Keyword: Abatement

Search Result 283, Processing Time 0.026 seconds

A Study on the Establishments of Aircraft Noise Abatement Procedures in Gimpo International Airport (김포공항 항공기 저소음 운항절차 수립을 위한 연구)

  • Kim, Yeon-Myung;Park, Jin-Woo;Kim, Young-Il;Son, Jung-Gon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.725-738
    • /
    • 2006
  • The final purpose of this study is to develop noise abatement procedures for minimizing damages caused by aircraft noise, to establish appropriate noise limits and to suggest a plan for imposing surcharges and penalties on aircraft infringing the noise limits. This study establishes noise abatement procedures and suggests a plan to complement and improve upon NMS in Gimpo International Airport by reviewing the NMS structure. In addition, this study establishes a noise limit at each noise monitoring system and a verification system to discriminate infringing aircraft. Finally, this study suggests a control plan for aircraft infringing the noise limit.

  • PDF

A Study on the Establishments of Aircraft Noise Abatement Procedures in Gimpo International Airport (김포공항 항공기 저소음 운항절차 수립을 위한 연구)

  • Kim, Yeon-Myung;Park, Jin-Woo;Kim, Young-Il;Son, Jung-Gon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.5 s.122
    • /
    • pp.379-390
    • /
    • 2007
  • The final purpose of this study is to develop noise abatement procedures for minimizing damages caused by aircraft noise, to establish appropriate noise limits and to suggest a plan for imposing surcharges and penalties on aircraft infringing the noise limits. This study establishes noise abatement procedures and suggests a plan to complement and improve upon NMS in Gimpo International Airport by reviewing the NMS structure. In addition, this study establishes a noise limit at each noise monitoring system and a verification system to discriminate infringing aircraft. Finally, this study suggests a control plan for aircraft Infringing the noise limit.

Study on Establishment of Aircraft Noise Abatement Procedures in Kimhae International Airport (김해국제공항 항공기 저소음 운항절차 수립을 위한 연구)

  • Kim, Yeon-Myung;Kim, Mi-Seon;Son, Jeong-Gon;Kim, Young-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.899-903
    • /
    • 2008
  • The purpose of this study is to establish the noise abatement procedures in Kimhae International Airport and also make noise limit and methods to monitor and detect an aircraft flying over Kimhae airport. First of all, noise monitoring system(NMS) should be set up, have a test and noise limit will be adjusted afterwards. Before applying Noise Abatement Procederes and noise limit, the amendment of Aviation Law 'article 108' required to proceed. The accumulative data and long term process of NMS will proceed and it is necessary to issue a notification of noise limit in phases.

  • PDF

Physiological Strains of Asbestos Abatement Work Wearing Protective Clothing in Hot-Humid Environments

  • Tochihara, Yutaka;Ohnaka, Tadakatsu
    • Fashion & Textile Research Journal
    • /
    • v.2 no.5
    • /
    • pp.411-415
    • /
    • 2000
  • To be able to work safely and efficiency, the Threshold Limit Values (TLV) for work in the heat are widely used. Since these TLV are only applicable to workers in regular clothing, TLV should be adjusted when applied to the asbestos removal workers who wear extra impermeable protective clothing. Although abbreviated guidelines for heat stress exposure have been proposed, literature advocating their use in the asbestos removal industry is limited. Therefore, we planed a survey to evaluate the workload of asbestos abatement workers in summer, and an experiment with climatic chambers to evaluate the effects of resting in a cool environment between work periods. From these studies, we got following conclusions. There is a high risk of suffering from heat illness by asbestos abatement work in summer in Japan. It is proposed to create a cool room inside the workplace of asbestos abatement work to reduce thermal stress.

  • PDF

Comparison of Noise Abatement Policies in Advanced Countries and Korea (선진국과 한국의 소음저감정책 비교)

  • Kang, Dae-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.558-567
    • /
    • 2011
  • One of the main objectives of noise control act is to define and ensure application and respect of noise exposure limits. Most advanced countries have prepared a legal framework for noise limits either by national laws, ordinances or municipal by-laws. A large number of advaced countries have adopted the $L_{eq}$ index for the main sources of noise (road, railway, industry). The exception is aircraft noise for which regulatory practice is highly disparate. These differences in the indices adopted, the periods and areas to which regulations apply, definitions of measurement conditions and ways in which noise levels are calculated make it difficult to compare the current advanced countries standards. This study presents the current noise abatement policy of the advanced countries and proposes the improvement of the current noise abatement policy of Korea to catch up with it of the advanced countries.

  • PDF

Numerical Study on the Performance Analysis of Plume Abatement Cooling Tower with Dry Type Heat Exchanger

  • Kim, Byung-Jo;Choi, Young-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • This study treats the numerical analysis of performance and design for plume abatement wet/dry cooling tower with a dry type heat exchanger. A two-dimensional analysis is performed using the finite volume method for mechanical draft counterflow and crossflow tower. For a coupling problem between water and air system, a turbulent two phase flow is considered. The Effectiveness-NTU method is used for modeling of the dry type heat exchanger. The parametric simulations such as the relative flowrate of air and attachment length of an air mixer are performed to examine the effect on plume abatement. It is found that if the relative air flowrate ratio and the adequate air mixer type are chosen well in addition to the ratio of water to air flowrate, the loss of cooling capacity and the additional cost are reduced and the plume is abated.

Comparing $CO_2$ Abatement Cost Patterns of OECD Countries (이산화탄소 감축정책에 따른 OECD 국가들의 GDP 손실액 패턴 분석)

  • Lee, Seung-Wan;Cho, Yong-Sung
    • Journal of Environmental Policy
    • /
    • v.6 no.4
    • /
    • pp.55-81
    • /
    • 2007
  • Most studies on $CO_2$ abatement cost with a computational general equilibrium(CGE) model focus on a specific country. On the contrary, this study compares and analyses the $CO_2$ abatement cost functions across 20 countries, consisting of OECD countries, China and Brazil, with a CGE model. For this purpose, we estimate the GDP loss from $CO_2$ emission reduction, assuming the 4 sector model. Our findings show that those cost curves are convex but different among the countries. However, despite of the difference in the cost curios, we have found that one group of countries has the relatively constant average abatement cost and the other group has the increasing average cost. The reason why such a pattern occurs is explained in terms of the variations of value-added and $Co_2$ emission coefficient by sector across the countries. As an environmental policy implication, this study presents information about which country is similar to one another in terms of the abatement cost.

  • PDF

Effects of the Odor Abatement System in a Naturally Ventilated Growing Finishing Pig House (자연환기식 육성.비육돈사의 악취탈취장치 적용효과)

  • Lee, S.H.;Yun, N.K.;Kim, K.W.;Yum, S.H.;Cho, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2008
  • Ammonia gas is one of the malodorous gases from swine production facilities, such as manure storage tank, manure fermentation facilities, and livestock houses, etc. Ammonia gas from swine house is being emitted at relatively low concentrations throughout the year. Therefore, livestock facilities were continuously ventilated to supply fresh air for respiration of the animals internal the livestock facilities. The swine facilities need very high ventilation rate to control the inside environmental conditions. The deodorization system of the livestock facilities must be developed considering the ventilation rates. The odor abatement system was installed in order to improve the internal environment of the naturally ventilated growing-finishing pig house. The system which distributes the deodorized air into inner space of the swine house by using plastic duct was installed. Since the internal environment, effected by the operation of the odor abatement system, is monitored by closing the winch curtain installed on the side wall of the pig house, the experiment was practiced at the season when the internal environment becomes aggravated, winter. The effects on the improvement in the internal environment of swine house by operating the odor abatement system are as follows ; 1. By re-distributing the air which was deodorized by the odor abatement system installed in the pig house, the result showed that the concentration of ammonia gas is decreased approximately 33.3% compared with that before operating odor abatement system. 2. The effect on the pig house's ammonia gas reduction was found that the ventilation rate was less than $0.5m^3$/min head. The effect of the operation of the odor abatement system showed to be scarce when the ventilation rate increases because of the influx of external fresh air makes the quantity of diluted air more than those of the odor abatement system. 3. The perishment rate of the pigs which were brooded until slaughtering decreased about 3.8% by operating the odor abatement system in the growing-finishing pig house. Also, after operating the odor abatement system, the stinging of the eyes, suspension dust, etc were decreased when going into swine house for management.

  • PDF

A Study on the Factors Affecting Asbestos Exposure Level from Asbestos Abatement in Building Demolition Sites (석면 해체·제거시 공기 중 노출수준과 영향요인)

  • Kim, Ji-Yeong;Lee, Song-Kwon;Lee, Jeong Hee;Lim, Mu Heok;Kang, Sungwook;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was examined to find out asbestos exposure level the factors which affected the level at asbestos abatement sites. We visited a total of thirteen building demolition sites(3 apartments, 3 schools, 4 stores, and 3 houses) were visited to collect samples and related data from August to November, 2006. The results of this study were as follows 1. The results of an analysis of bulk samples to identify types of asbestos at the asbestos abatement sites showed that the kinds of the asbestos detected were chrysotile by 50.0%, were tremolite by 2.6%, and were the contents of chrysotile by 3 to 20%. 2. The geometric mean concentration of asbestos was 0.007 f/cc(range 0.001-0.34 f/cc) and its geometric standard deviation was 5.83. Of the samples, however, 12 exceeded the Korean Occupational Exposure Limit(0.1f/cc). 3. Of the materials, textile material had the highest concentration with geometric mean of 0.016 f/cc. When asbestos-containing materials were removed using T type tools, the geometric mean concentration of asbestos was 0.061 f/cc. The level by this method was much higher than by other removal methods. In analysis by the type of building, the geometric mean concentration of asbestos in stores was 0.042 f/cc and was higher than in other buildings. 4. The Poisson regression analysis was applied to find out the factors that affect the airborne asbestos concentration. As a result of the analysis, removal using a T type tool was the most important factor affecting the asbestos concentration(p<0.01). In conclusion, the airborne asbestos concentration(geometric mean) in asbestos abatement sites was 0.007 f/cc(0.001~0.34 f/cc), and 12(14.6%) of all samples were over the 0.1 f/cc. These results showed that asbestos abatement workers have been exposed to the high level of airborne asbestos because they have not been keeping asbestos removal rule. In accordance with increases of the number of building demolition sites, the better government regulation on asbestos abatement methods should be made and be performed well at building demolition sites.

Study on Surveying and Improving of Risk Assessment System for Asbestos Abatement (석면 해체 및 제거 작업의 안전성평가 제도에 대한 설문조사 및 개선 방안에 관한 연구)

  • Chang, Jaepil;Rho, Youngman;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.205-212
    • /
    • 2020
  • Objectives: The purpose of this study was to identify the needs and improvement measures of the risk assessment system through a survey of asbestos abatement companies. Methods: This study prepared a questionnaire that includes improvement measures for the risk assessment system(six questions) and the necessity of a risk assessment system for asbestos abatement(one question). The questionnaire was sent to 2,170 asbestos abatement companies and returned by 83 companies(return rate = 3.8%). We conducted frequency analysis, ANOVA, and Chi-squared testing at the 5% significance level. Results: This study analyzed the survey results and identified six main opinions on the risk assessment system and improvement measures. First, giving an advantage to companies with a high grade(S and A grades) in public bidding and/or qualification screening showed a similar preference(agree: 50.6%, disagree: 49.4%). Second, 57.6% of the respondents wanted to allow air showers along with water showers for low risk asbestos work. However, 23.2% of the respondents asserted that only a water shower should be allowed since there is no scientific evidence supporting the removal of asbestos by air shower. Third, in order to prevent missing the enrollment of workers, simply submitting a change report should be allowed when any worker is changed (40.0%). Fourth, 43% of the respondents answered that they did not know how to calculate the proper number of negative pressure units. The reasons given were a lack of guidelines or standards(38.9%), inconvenience (36.1%), and absence of education(25%). Fifth, the respondents who were favorable toward the necessity of a risk assessment system gave higher scores compared to unfavorable respondents on the necessity of the management of workers' work history(favorable respondent = 3.96 out of 5, unfavorable respondent = 2.68) and the necessity of professional training for workers(favorable respondent = 3.71, unfavorable respondent = 2.56). Finally, the respondents favorable toward a risk assessment system showed higher scores on the awareness of calculating the proper number of negative pressure units(4.79) compared to unfavorable respondents(3.3). Conclusions: The opinions of asbestos abatement companies identified through the survey in this study can be usefully utilized as fundamental information to improve the risk assessment system.