• Title/Summary/Keyword: ATPdraw

Search Result 85, Processing Time 0.044 seconds

Field Test and Analysis for Proper Location of Protective Equipment in Underground Distribution System (지중배전계통 보호설비 적정위치 선정을 위한 실증시험과 해석)

  • Yun, Chang-Sub;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.773-782
    • /
    • 2008
  • This paper describes the method for proper location of protective equipment in underground distribution cable through field test and analysis at testing lines. To prove the reliability for analysis simulated by EMTP/ATPDraw, the testing results obtained by the real test and the analysis for the same test lines were compared each other. The accuracy of analysis was proved by the comparison. Over voltages were measured and analyzed at each point of cable and switches in case of which lightning surge current was applied. The analysing method was applied to real distribution systems to select the proper location of protective equipment. It is evaluated that the location of protective equipment was properly selected.

A Study on Recloser Operation According to Recovery Characteristics of Superconducting Fault Current Limiter (초전도 한류기 회복특성에 따른 재폐로 차단기 동작 연구)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.379-380
    • /
    • 2008
  • For proper application and operation of a SFCL(Superconducting Fault Current Limiter), the prior investigation of fundamental characteristics and its effects to the distribution systems are needed. In this paper, the resistive type SFCL and recloser were developed by using EMTP/ATPDraw and MODELS language. To analyze the effect of recovery characteristics of SFCL according to recloser operation in distribution systems, case studies have been simulated and investigated.

  • PDF

Asymmetry Components Reduction using Superconducting Fault Current Limiter Operation in Transient Period (비대칭 고장전류 저감을 위한 초전도 한류기 동작 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.381-382
    • /
    • 2008
  • This paper presents a novel scheme for reducing an asymmetry current with SFCL (Superconducting Fault Current Limiter) operation during transient period, when a fault occurs in power systems. The main idea is installation an auxiliary SFCL with characteristics, which reduces the asymmetry fault current in first half cycle before the operating of main SFCL. For proper activities of SFCLs, the principle of asymmetry current nature is reviewed. A scheme of asymmetry components reduction with SFCL is then explained. The EMTP/ATPDraw model of SFCLs using MODELS language developed and simulated to verify the performance and effectiveness.

  • PDF

A Study on the Analysis of Line Constants Model in EMTP (EMTP의 선로 모델의 비교분석에 관한 연구)

  • Oh, Kwang-Wun;Yeo, Sang-Min;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2287-2288
    • /
    • 2008
  • 전력계통에는 수많은 기기가 복잡하게 연계 되어있으므로 지락사고가 일어났을 때 피해의 정도가 크다. 그래서 선로 모델링이 중요한데 선로 모델에는 많은 모델이 있기 때문에 각각의 모델들의 특성을 먼저 알아야한다. 그래서 본 논문에서는 몇 가지 선로 모델을 이용하여 모의 하여 결과를 비교해 보았다. 모의 Tool로는 EMTP/ATPDRAW를 이용하였고, 모의한 선로 모델은 Bergeron 비연가 모델, 연가 모델과 PI 등가 모델, 분포정수 모델을 이용하여 당진에서 신안성까지의 송전선로를 모델링하였다. 정상상태 일 때와 A상에서 지락사고가 일어났을 경우를 가정하고 모의하여 파형을 비교하였다.

  • PDF

Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge (뇌서지로 인한 피뢰기 열화시 과도상태 분석)

  • Lim, Sung-Yong;Kim, Kyu-Ho;Rhee, Sang-Bong;Kim, Soo-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

An Algorithm for Electric Vehicle Charging in PV integrated Power System (태양광 발전 연계 계통에서의 전기자동차 충전 알고리즘)

  • Lee, Woong-Hee;Kim, Jun-Hyuk;Lee, Soon-Jeong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.341-342
    • /
    • 2015
  • Attention has been focused on how to charge an electric vehicle in accordance with the increase of interest in the electric vehicle in recent years. The charging of an electric vehicle with a solar power is way to increase the stability of the grid and to supplement the grid power demand. In this paper, the EMTP / ATPDraw presents a method of charging an electric vehicle in connection to the grid and the solar power system, and analyze the trends in supply power from the solar power system according to changes in temperature and irradiation.

  • PDF

System Effects by Operation Characteristics of Superconducting Fault Current Limiters in Distribution Systems (배전계통 초전도 한류기 동작특성에 따른 계통 영향 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1135-1140
    • /
    • 2008
  • Superconducting fault current limiters (SFCL) have been progressing due to the development of superconducting technology. The resistor type SFCL is one of the promising current limiting devices in power system for its effective operation. For proper application and operation of a SFCL, the prior investigation of fundamental characteristics and its effects to the distribution systems are needed. The most important current limiting behavior of a SFCL is dominated by quenching and recovery characteristics. In this paper, the resistive type SFCL was developed by using EMTP/ATPDraw and MODELS language. The operating characteristics and current limiting behaviors of the SFCL in distribution systems have been simulated and investigated.

A Study on the Characteristic and Rising Cause of Sheath Circulating Current by Analysis and Measurement (해석 및 측정을 통한 시스순환전류 특성 및 상승원인 검토)

  • Gang, Ji-Won;Yang, Hae-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.525-533
    • /
    • 2002
  • It is common to install multiple lines in the same route. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Especially, the installation type, unbalance section length between joint boxes and zero sequence current by distribution cable have an effect on the rising of sheath circulating current in the underground transmission system. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. This paper describes the relation analysis of sheath circulating current and burying types. And also, a detailed analysis on rising cause and characteristic of sheath circulating current by considering various unbalanced conditions presents using analysis and measurement regarding cable systems which have the problem of excessive sheath circulation current.

A Study on the HTS Distribution Cable System Modelling and the Current Distribution of Layers (초전도 케이블 시스템 구성과 레이어의 전류 분배에 관한 연구)

  • Kim, Nam-Yoel;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.315-318
    • /
    • 2002
  • The use of high-temperature superconducting materials for transmission cable application is being realized in prototype situation. HTS cable systems have been installed in laboratories and tested successfully around the world. In korea. the first step in development of superconducting cables is distribution system. In this paper. it is proposed the HTS distribution system modeling using ATPDraw and EMTDC programs. In the multilayer conductor, the inner layers have higher impedance than the outer layers. As a result, the current concentrate$ in the outer layers. This paper presents the result of the current distribution in EMTDC.

  • PDF

Analysis of Lightning Overvoltage on the Combined Power Transmission Line and Actuation of Arrester (혼합송전계통에서 뇌과전압해석 및 피뢰기 동작특성 검토)

  • Kim, Nam-Yoel;Kim, Kyoung-Ho;Lee, Jong-Beom;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.491-493
    • /
    • 2001
  • This paper describes the effect of lightning current on combination transmission line. In the paper, an lightning current which can generate 2/80[${\mu}s$]. 20[kA] - 40[kA] waveform is modeled in ATPDraw. The lightning current invaded to the overhead power transmission line propagates to the underground power cable. The simulation was performed to analyze the effect of arrester location and overvoltage occurred in power cable.

  • PDF