• Title/Summary/Keyword: ATPdraw

Search Result 85, Processing Time 0.037 seconds

A Basic Study on the Modeling for Analysis of Superconducting Cable (초전도케이블 해석용 모델링에 관한 기초연구)

  • 김남열;정채균;이종범
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.267-270
    • /
    • 2002
  • It is very important to analyze the superconducting power cables by the modeling for correct and reasonable cable design suitable for the domestic situation of power systems. This paper describes the basic modeling for superconducting power cables using ATPDraw. And also it is shown the line constants of cold dielectric coaxial type which is one of the HTS cables. It is compared with the line constants of general two kinds of power cables(OF, XLPE).

  • PDF

Development of measurement indices of power quality event based on S-transform (S-Transform 기반의 전력품질 이벤트의 측정 지수 개발)

  • Kim, Se-Jin;Lee, Soon-Jeong;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.43-44
    • /
    • 2011
  • S-Transform은 어떠한 신호의 변환 후 원 신호의 주파수 및 크기를 모두 알 수 있는 효과적인 방법이다. 따라서, 본 논문에서는 IEEE에서 제시한 전력품질 이벤트의 분류를 기반으로 S-Transform 기반의 전력품질 이벤트의 측정지수를 제안하였다. 제안한 측정지수의 효율성을 검증하기 위하여, ATPDraw를 이용하여 고장 및 비선형 부하를 모의하였다. 그 결과를 이용하여 S-Transform을 수행하여 제안된 측정지수의 효율성을 검증하였다.

  • PDF

Analysis of Switching Overvoltage on Operating Reclosing in Combined Transmission Systems (혼합송전계통에서 재폐로 시행시 개폐과전압 해석)

  • Lim, Kwang-Sik;Lee, Jong-Boem;Jung, Chae-Kyun;Kang, Ji-Won;Park, Hung-Sok
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.391-393
    • /
    • 2008
  • This paper is analysed by switching overvoltage on operating reclosing in 154 [kV] combined transmission systems. Combined transmission systems are modeled by EMTP/ATPDraw program. It is fault condition that simulate high resistance earth fault. The simulation is carried out considering variation of parameters such as resistance value of fault point and rate of underground line.

  • PDF

The Effects of Common Ground according to Fault Conditions in The Underground Transmission and Distribution System (고장조건에 따른 지중송배전계통에서 공통접지의 영향 분석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.285-287
    • /
    • 2007
  • This paper describes that the effect on the other system is generated by the single line to ground fault of the underground transmission systems and distribution systems established the common ground in trefoil. Each system is modeled by EMTP/ATPDraw and the system carry out simulations according to the various values of common ground to analyse. In this study, the result of analysis based on simulation suggests protection method and ground system of each system.

  • PDF

An Analysis of the Impact of the PV generation on Fuse Coordination (퓨즈협조에 대한 태양광 발전의 영향 분석)

  • Cho, Hae-In;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.474_475
    • /
    • 2009
  • Recently the grid-connected PV system is increased in the power system. According to this trend, protection coordination issues are becoming more important when the PV generation is connected to the power system. In this paper, we model the PV system using EMTP/ATPDRAW and analyze the impact of the PV generation for the fuse coordination.

  • PDF

A Detection Scheme of a Secondary Arc Extinction Using Correlation of a Fault Voltage (고장 전압의 correlation을 이용한 2차 아크 소호 판별)

  • Jang, Won-Hyeok;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.340_341
    • /
    • 2009
  • This paper suggests a detection scheme of a secondary arc extinction using the peak value of a fault voltage estimated by correlation algorithms. The system implemented in this paper is based on a Korean 765 kV system and the suggested proposed scheme is tested on the system. The performance of the method is analyzed by using Electro-Magnetic Transients Program (EMTP)/ATPDraw.

  • PDF

Neutral Current Calculation in One Step Type Pole (1단장주 중성선 전류 계산)

  • Seo, Hun-Chul;Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.480-481
    • /
    • 2006
  • This paper presents computation of the neutral torrent using KEPCO's distribution system model which is composed by only one step type poles. The used system model is modelled and simulated by using ATPDraw. And the neutral current is calculated by using EMTP/MODELS.

  • PDF

Lightning Overvoltage Analysis and Model Establishment of XLPE Cable Underneath a Bridge on Underground Power Cable Systems (지중송전계통에서 XLPE케이블의 교량첨가시 모델수립 및 뇌과전압 해석)

  • Kim, Cheol-Ho;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2243-2244
    • /
    • 2008
  • In this paper, XLPE cable underneath a bridge is modelled using EMTP/ATPDraw. Bridge section is also modelled by mutually coupled parallel conductor with XLPE cable. This paper is analysed the overvoltge by structure change of bridge section when the lightning occurs on the system.

  • PDF

A Study on the Reclosing Operation of Distribution System considering the ESS (ESS를 고려한 배전계통 재폐로 동작에 관한 연구)

  • Seo, Hun-Chul;Kim, Chul-Hwan;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.583-584
    • /
    • 2015
  • Energy Storage System(ESS) can be used as several purposes such as uninterruptible power supply (UPS), frequency regulation, maximum load cut, and etc. This paper analyzes and simulates the reclosing operation in distribution system with ESS for frequency regulation and maximum load cut. To solve the effect from ESS, two sequences in reclosing process are added to conventional reclosing. The modelings and simulations of reclosing operation using EMTP/ATPDraw are performed.

  • PDF

Analysis of lightning surge on the 345kV Gas Insulated Substation (345kV GIS 변전소 뇌써지 해석)

  • Kim, Jae-Kwan;Lee, Jong-Beom;Cho, Han-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.561-563
    • /
    • 2003
  • This paper deals with simulation of lightning overvoltage generated by back flashover entering 345[kV] Gas Insulated Substation. In order to protect the substation equipment against lightning surge, insulation coordination is performed with the lightning arrester. This paper suggests optimal location of lightning arrester using the EMTP/ATPDraw to mere economically and effectively reduce the lightning surge incoming overhead lines.

  • PDF