• Title/Summary/Keyword: ATJ 그라파이트

Search Result 3, Processing Time 0.018 seconds

Compressive Fracture Behavior of ATJ Graphite for Rocket Nozzle (로켓 노즐목에 이용되는 ATJ 그라파이트 압축거동 평가)

  • Choi, Hoon Seok;Seo, Bo Hwi;Kim, Jae Hoon;Moon, Soon Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1435-1440
    • /
    • 2014
  • The effects of the specimen size and temperature on the compressive strength of ATJ graphite were investigated. Compressive tests were conducted in accordance with ASTM C 965 at room temperature, $700^{\circ}C$ and $900^{\circ}C$. Three types of cylindrical specimen at room temperature were used in uniaxial tests, where the diameter-to - length ratios were one to two for the ASTM standard specimen, one to one for the Type I specimen, and one to 0.5 for the Type II specimen. Two kinds of cylindrical specimens, with and without antioxidant coating, were tested at elevated temperature. The Compressive strength of the expanded specimens(Type I, II) were slightly higher than that of standard specimen at room temperature. The compressive strength of a specimen with antioxidant coating increased as the temperature increased to $900^{\circ}C$. In contrast, that of the non-coated specimen decreases sharply due to the oxidation of the specimen.

A Characteristics of Crack Behavior on Graphite (그라파이트 재료의 고온 크랙특성 평가)

  • Koo, Song-Hoe;Lee, Young-Shin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.417-420
    • /
    • 2009
  • The purpose of the present study is to evaluate high temperature fracture toughness through the experimental and analytical method. The analysis method is proposed to simulate the fracture toughness of high temperatures. Load-COD curves of compact test specimen acquired by finite element method analysis using hypo elastic model are simulated to determine the crack initiation load on high temperatures. The results of experimental work are in accord with analysis in thermal shock test.

  • PDF

Conjugate Simulation of Heat Transfer and Ablation in a Small Rocket Nozzle (소형 시험모터의 노즐 열전달 및 삭마 통합해석)

  • Bae, Ji-Yeul;Kim, Taehwan;Kim, Ji Hyuk;Ham, Heecheol;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.119-125
    • /
    • 2017
  • Ablative material in a rocket nozzle is exposed to high temperature combustion gas, thus undergoes complicated thermal/chemical change in terms of chemical destruction of surface and thermal decomposition of inner material. Therefore, method for conjugate analysis of thermal response inside carbon/phenolic material including rocket nozzle flow, surface chemical reaction and thermal decomposition is developed in this research. CFD is used to simulate flow field inside nozzle and conduction in the ablative material. A change in material density and a heat absorption caused by the thermal decomposition is considered in solid energy equation. And algebraic equation under boundary layer assumption is used to deduce reaction rate on the surface and resulting destruction of the surface. In order to test the developed method, small rocket nozzle is solved numerically. Although the ablation of nozzle throat is deduced to be higher than the experiment, shape change and temperature distribution inside material is well predicted. Error in temperature with experimental results in rapid heating region is found to be within 100 K.