• Title/Summary/Keyword: AT feeder system

Search Result 153, Processing Time 0.035 seconds

Removal of COD and T-N caused by ETA from Nuclear Power Plant Wastewater using 3D Packed Bed Bipolar Electrode System (3D 복극충진전기분해를 이용한 원전 ETA에 의해 유발된 폐수 내 COD 및 T-N 제거)

  • Kim, Han-Ki;Jeong, Joo-Young;Shin, Ja-Won;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.3
    • /
    • pp.409-421
    • /
    • 2012
  • Ethanolamine (ETA) is mainly used to prevent corrosion of pipe in secondary cooling system of nuclear power plant. Condensed ETA in wastewater could increase COD and T-N when it was emitted to natural water system. Compared to conventional treatments, electrochemical oxidation process using packed bed bipolar electrodes was adopted to treat COD and T-N. According to arrangement of feeder electrode, single packed bed bipolar electrode reactor and multi-paired packed bed bipolar reactor were developed and conventional zero-valent iron (ZVI) was selected as conducting bipolar electrode. Bipolar electrodes were coordinated three-dimensionally in the reactor. The experimental results showed that COD and T-N was little removed in unit system at different pH condition (pH 8 and 11) on 100V. However, in multi-paired system that applied 600V, COD was eliminated 80.85% (anode-cathode-anode, A-C-A) and 85.11% (cathode-anode-cathode, C-A-C), respectively. T-N was also removed 96.88% (A-C-A) and 90.63% (C-A-C), simultaneously. Current efficiency was estimated both single and multi-paired system. At unit bipolar packed bed reactor, current efficiency was almost zero, however in multi-paired system, current efficiency was 300~500% at A-C-A and 250~350% at C-A-C. Current efficiency was over 100% hence it was confirmed that this system is more effective than conventional electrochemical oxidation system.

The maintenance record of the KSTAR helium refrigeration system

  • Moon, K.M.;Joo, J.J.;Kim, N.W.;Chang, Y.B.;Park, D.S.;Kwag, S.W.;Song, N.H.;Lee, H.J.;Lee, Y.J.;Park, Y.M.;Yang, H.L.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.6-9
    • /
    • 2013
  • Korea Superconducting Tokamak Advanced Research (KSTAR) has a helium refrigeration system (HRS) with the cooling capacity of 9 kW at 4.5 K. Main cold components are composed of 300 tons of superconducting (SC) magnets, main cryostat thermal shields, and SC current feeder system. The HRS comprises six gas storage tanks, a liquid nitrogen tank, the room temperature compression sector, the cold box (C/B), the 1st stage helium distribution box (DB#1), the PLC base local control system interconnected to central control tower and so on. Between HRS and cold components, there's another distribution box (DB#2) nearby the KSTAR device. The entire KSTAR device was constructed in 2007 and has been operated since 2008. This paper will present the maintenance result of the KSTAR HRS during the campaign and discuss the operation record and maintenance history of the KSTAR HRS.

Autonomous Separation Methodology of Faulted Section based on Multi-Agent Concepts in Distribution System (멀티 에이전트 개념에 기반한 배전계통의 분산 자율적 고장구간 분리 기법)

  • Ko, Yun-Seok;Hong, Dae-Seung;Song, Wan-Seok;Park, Hak-Ryeol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.6
    • /
    • pp.227-235
    • /
    • 2006
  • In this paper, autonomous separation methodology of faulted section based on network is proposed newly, which can minimize the outage effect as compared with the existing center-based faulted section separation method by determining and separating autonomously the faulted section by the free operation information exchange among IEDs on the feeder of distribution system. The all IEDs is designed in network in which client/server function is possible in order to separate autonomously the faulted section using PtP(Peer to Peer) communication. Also, Inference based solution of IED for the autonomous faulted section separation is designed by rules obtained from the analyzing results of distribution system topology. Here, the switch IEDs transmit on network the fault information utilizing on multi-casting communication method, at the fame time, determine selfly whether they operates or not by inferencing autonomously the faulted section using the inference-based solution after receiving the transmitted information. Finally, in order to verify the effectiveness and application possibility of the proposed methodology, the diversity fault cases are simulated for the typical distribution system.

An Enhanced Instantaneous Circulating Current Control for Reactive Power and Harmonic Load Sharing in Islanded Microgrids

  • Lorzadeh, Iman;Abyaneh, Hossein Askarian;Savaghebi, Mehdi;Lorzadeh, Omid;Bakhshai, Alireza;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1658-1671
    • /
    • 2017
  • To address the inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids (MGs) with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on the active compensation of circulating voltage drops is proposed in this paper. Using the proposed strategy, reactive power and harmonic currents are shared accurately and proportionally without knowledge of the feeder impedances. Since the proposed local controller consists of two well-separated fundamental and harmonic voltage control branches, the reactive power and harmonic currents can be independently shared without having a remarkable effect on the amplitude or quality of the DGs voltage, even if nonlinear (harmonic) loads are directly connected at the output terminals of the units. In addition, accurate load sharing can also be attained when the plug-and-play performance of DGs and various loading conditions are applied to MGs. The effects of communication failures and latency on the performance of the proposed strategy are also explored. The design process of the proposed control system is presented in detail and comprehensive simulation studies on a three-phase MG are provided to validate the effectiveness of the proposed control method.

Analysis of Propagation Characteristics of Lightning Surge according to the Type of Branch Line in Distribution System (배전계통에서 분기선로 형태에 따른 뇌서지 전달특성 해석)

  • Seo, Hun-Chul;Han, Jun;Kim, Yun-Gon;Kim, Chul-Hwan;Choi, Sun-Kyu;Lee, Byung-Sung;Rhee, Sang-Bong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1376-1382
    • /
    • 2013
  • This paper analyzes the propagation characteristics of lightning surge according to the type of branch line in distribution system. The types of branch line considered are H-type and PI-type. At each type, the length of main feeder is same, while the number and length of branch line are different. The distribution line is modeled and the various lightning locations are simulated by Electromagnetic Transient Program(EMTP). For each lightning, the various measuring points are selected. Based on the simulation results, the propagation characteristics of lightning surge at each measuring point are analyzed. The analyzed results are verified by travelling wave theory.

The research for the application of polymer support insulator used in DC railway system (직류전기철도에서의 고분자 지지애자 적용에 관한 연구)

  • Lee, Gi-Sung;Kim, Yoon-Sik;Sim, Jae-Suk;Jung, Ho-Sung;Lee, Ki-Won;Cho, Ho-Ryung
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.371-377
    • /
    • 2009
  • The use of polymer insulator has increased all over the world. As of 2000's KEPCO has used it fully since they introduced it in early 1990's. In Korea it is very widely used by KORAIL which uses AC 25 kV system in the ground electric car line. And It is also used in tunnel electric car line to support AT feeder line. But it has not been used in the section of DC 1500 V. In case of DC 1500 V electric railway system It is has been developed by research institutes by means of R&D projects since 2008. The user cleans porcelain insulators regularly by water because of dusts and pollution. In case of polymer insulators It is very easy to be made dirty by pollution because of the material properties and hard to be cleaned by cleansing. In accordance with these reasons It is worried about deterioration. This paper deals with anticipating problems when we apply it to DC electric railway system and the procedure for testing polymer support insulator.

  • PDF

A New Load Flow Algorithm based on DAS with Considering Distributed Load (배전자동화 시스템에서 분포부하를 고려한 새로운 조류계산 알고리즘)

  • Yang, Xia;Choi, Myeon-Song;Lim, Il-Hyung;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.169-170
    • /
    • 2006
  • In this paper, A new algorithm for load flow calculation is proposed for radial distribution network. Feeder Remote Terminal Unit (FRTU) is utilized to collect data such as current magnitude and angle of power factor at each node. Proposed algorithm is based on the model of distributed load in distribution system. Load flow calculation is using four terminal constants method.

  • PDF

The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems (ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정)

  • Kim, Mi-Young;Hara, Ryoichi;Kita, Hiroyuki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

Development of Industrial Wood Pellet Boiler with High Safety (안전성이 높은 산업용 목재펠릿 보일러 개발)

  • Chung, Chan Hong;Park, Min Cheol;Lee, Seong Young
    • Journal of Applied Reliability
    • /
    • v.13 no.1
    • /
    • pp.31-44
    • /
    • 2013
  • Recently, due to the high rise of energy costs and environmental problem issues, much attention has been paid to wood pellets. Wood pellets are produced by compressing woody biomass into cylindrical form. Wood pellets are suitable for use at various scales in industrial furnaces for heat production to replace conventional fossil fuel energy sources since the use of wood pellet that is carbon neutral can alleviate global warming. This study presents the result of developing two industrial wood pellet boilers with high safety having capacities of 290kW and 440kW. Efficiency has been improved by using a rotating screw bar grate burner. Special attention has been paid to the improvement of the safety of the wood pellet boilers from backfire by adopting a triple protecting system composed of a rotary feeder, an air curtain, and a backfire protecting DC-fan.

Synthesis of Ultrafine Powders for Aluminum Nitride by DC Thermal Plasma (직류 열플라즈마를 이용한 질화알루미늄 초미세분말의 합성)

  • 안현;허민;홍상희
    • Journal of Surface Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.45-59
    • /
    • 1996
  • Ultrafine powders(UFPs) of aluminum nitride(AlN) have been synthesized by chemical reactions in the nitrogen atmosphere and the gaseous aluminum evaporated from Al powders in thermal plasmas produced by a DC plasma torch. A synthesis system consisting of a plasma torch, a finely-controllable powder feeder, a reaction chamber, and a quenching-collection chamber have been designed and manufactured, and a filter for gathering AlN UFPs produced by the quenching process subsequent to the synthesis is set up. The synthesis process is interpreted by numerical analyses of the plasma-particle interaction and the chemical equilibrium state, respectively, and a fully-saturated fractional factorial test is used to find the optimum process conditions. The degrees and ultrafineness of synthesis are evaluated by means of SEM, TEM, XRD, and ESCA analyses. AlN UFPs synthesized in the optimum process conditions have polygonal shapes of the size of 5-100 nm, and their purities differ depending on collecting positions and filter types, and the maximum purity obtained is 72 wt% at the filter.

  • PDF