• Title/Summary/Keyword: ASTRA

Search Result 46, Processing Time 0.034 seconds

COVID-19 Vaccination for Pilots and Air Traffic Controllers (항공종사자와 코로나바이러스감염증-19 백신 예방 접종)

  • Kwon, Young Hwan
    • Korean journal of aerospace and environmental medicine
    • /
    • v.31 no.1
    • /
    • pp.13-16
    • /
    • 2021
  • The coronavirus disease-19 (COVID-19) vaccine is expected to play an important role in stopping the pandemic. Studies show that COVID-19 vaccines are effective at keeping you from getting COVID-19. Getting a COVID-19 vaccine will also help keep you from getting seriously ill even if you do get COVID-19. Efforts to find an effective vaccine against severe acute respiratory syndrome coronavirus 2 have progressed unprecedentedly through active support from public research grants and private-public partnership programs. Clinical studies have been actively conducted, and some vaccines are being vaccinated with approval for urgent use. The WHO has approved and supplied the Pfizer-BioNTech COVID-19 vaccine and the Oxford-AstraZeneca COVID-19 vaccine. In Korea, the Oxford-AstraZeneca vaccine was approved for urgent use, and vaccination began on February 26, 2021. In this paper, the efficacy and side effects of each vaccines and the effect on pilots and air traffic controllers related to COVID-19 vaccination were investigated in terms of aviation medicine.

A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

  • Kang, In-Ho;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.190-195
    • /
    • 2011
  • PURPOSE. This study evaluated the initial stability of different implants placed above the bone level in different types of bone. MATERIALS AND METHODS. As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Br${\aa}$nemark System$^{(R)}$ Mk III TiUnite$^{TM}$, Straumann Standard Implant SLA$^{(R)}$, and Astra Tech Microthread$^{TM}$-OsseoSpeed$^{TM}$) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis. RESULTS. In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Br${\aa}$nemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants. CONCLUSION. The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level.

Factors Influencing COVID-19 AstraZeneca (ChAdOx1) Vaccination and Side Effects among Health Care Workers in an Acute General Hospital (중소병원 의료기관 종사자의 COVID-19 AstraZeneca (ChAdOx1) 백신 접종 영향요인과 접종 후 이상 반응 실태조사)

  • Lee, Sunhwa;Choi, Jeong Sil
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.318-329
    • /
    • 2021
  • Purpose: This study was conducted to identify factors affecting COVID-19 vaccination and associated side effects among health care workers in a small and medium-sized hospital. Methods: In May 2021, 301 workers out of a total of 670 working in a small and medium-sized hospital in Gyeonggi-do, were surveyed. The small and medium-sized hospital treats patients with COVID-19. Health care workers across different medical institutions responded with self-reported internet questionnaires. Factors influencing COVID-19 vaccination were analyzed via logistic regression. Results: Out of 301 subjects, 89.0% showed an intention to inoculate, and 85.7% were vaccinated against COVID-19. The most frequent reason for vaccination was responsibility as a medical worker. The fear of adverse reactions was the most frequent reason for non-vaccination. Adverse reactions after inoculation occurred in 70.9% of cases, and 30.6% were referred for treatment of adverse reactions. The factors ultimately influencing COVID-19 vaccination were vaccination intention, previous side effects from other vaccinations, occupation, and age. Conclusion: In order to improve the effectiveness of COVID-19 vaccination, a systematic approach is required to determine the risk factors associated with the young age of the administrative staff/personnel, subjects with a history of side effects associated with other vaccines, and health care workers who do not intend to be vaccinated. It is important to develop strategies to improve immunization. In addition, accurate and essential information regarding the side effects of vaccination is needed, along with appropriate education and publicity.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

Fit analysis of CAD-CAM custom abutment using micro-CT (Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석)

  • Min, Gwang-Seok;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.370-378
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. Materials and methods: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. Results: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutment-screw interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). Conclusion: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.

Applied Computational Tools for Crop Genome Research

  • Love Christopher G;Batley Jacqueline;Edwards David
    • Journal of Plant Biotechnology
    • /
    • v.5 no.4
    • /
    • pp.193-195
    • /
    • 2003
  • A major goal of agricultural biotechnology is the discovery of genes or genetic loci which are associated with characteristics beneficial to crop production. This knowledge of genetic loci may then be applied to improve crop breeding. Agriculturally important genes may also benefit crop production through transgenic technologies. Recent years have seen an application of high throughput technologies to agricultural biotechnology leading to the production of large amounts of genomic data. The challenge today is the effective structuring of this data to permit researchers to search, filter and importantly, make robust associations within a wide variety of datasets. At the Plant Biotechnology Centre, Primary Industries Research Victoria in Melbourne, Australia, we have developed a series of tools and computational pipelines to assist in the processing and structuring of genomic data to aid its application to agricultural biotechnology resear-ch. These tools include a sequence database, ASTRA, for the processing and annotation of expressed sequence tag data. Tools have also been developed for the discovery of simple sequence repeat (SSR) and single nucleotide polymorphism (SNP) molecular markers from large sequence datasets. Application of these tools to Brassica research has assisted in the production of genetic and comparative physical maps as well as candidate gene discovery for a range of agronomically important traits.

Comparison of COVID-19 Vaccines Introduced in Korea

  • Lee, Chang-Gun;Lee, Dongsup
    • Biomedical Science Letters
    • /
    • v.28 no.2
    • /
    • pp.67-82
    • /
    • 2022
  • The prevalence of SARS-CoV-2 led to inconsistent public health policies that resulted in COVID-19 containment failure. These factors resulted in increased hospitalization and death. To prevent viral spread and achieve herd immunity, the only safe and effective measure is to provide to vaccinates. Ever since the release of the SARS-CoV-2 nucleotide sequence in January of 2020, research centers and pharmaceutical companies from many countries have developed different types of vaccines including mRNA, recombinant protein, and viral vector vaccines. Prior to initiating vaccinations, phase 3 clinical trials are necessary. However, no vaccine has yet to complete a phase 3 clinical trial. Many products obtained "emergency use authorization" from governmental agencies such as WHO, FDA etc. The Korean government authorized the use of five different vaccines. The viral vector vaccine of Oxford/AstraZeneca and the Janssen showed effectiveness of 76% and 66.9%, respectively. The mRNA vaccine of Pfizer-BioNTech and Moderna showed effectiveness of 95% and 94.1%, respectively. The protein recombinant vaccine of Novavax showed an effectiveness of 90.4%. In this review, we compared the characteristics, production platform, synthesis principles, authorization, protective effects, immune responses, clinical trials and adverse effects of five different vaccines currently used in Korea. Through this review, we conceptualize the importance of selecting the optimal vaccine to prevent the COVID-19 pandemic.

A study on the compatibility of implant drivers (임플란트 드라이버의 호환성에 대한 연구)

  • Kim, Min-Soo;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.34-41
    • /
    • 2014
  • Purpose: In this study, the diameter of each implant driver was measured and compared to find out the compatibility of implant drivers. Materials and methods: Drivers from 12 implant systems being used in Dankook University Dental Hospital were included in this study. The shapes of the implant drivers were segregated, and the effective length and the diameter of upper, middle, lower part of driver tips were measured (n=10). The measured data were mathematically analyzed for its compatibility. Results: A driver with the smallest diameter (1.17 mm) had the highest compatibility at the upper part of driver tip. This driver could be used for a bigger driver up to 1.35 mm in diameter. There were several driver groups which had the same diameter so as to be interchangeable each other. In the middle part, the smallest diameter measured was 1.2 mm and this was able to replace a driver up to 1.40 mm diameter. Since the diameter generally became thicker from upper part (the tip of driver) to the lower part (the shank of driver), some drivers with bigger diameter at the upper part so which was failed to show any compatibility became compatible with a driver which had smaller diameter at the upper part but wider in the middle part. The compatibility of torx shape drivers were affected by the inner diameter of the drivers not only by the outer diameter. Furthermore, the inner diameter of torx drivers decided the compatibility between torx and hex drivers. Conclusion: From the study it was found that compatibility in drivers existed among certain implant systems and to check its compatibility the diameter at a certain effective length should be measured. However, there has been not enough studies about long-term use of compatible drivers, so effects of using compatible drivers on drivers and implants are unknown. Therefore, usage in inevitable cases only is recommended and further study is needed.