Characteristics of Auto-ignition for Trichlorosliane and Dichlorosilane-Trichlorosliane Mixtures (Trichlorosliane 및 Dichlorosilane-Trichlorosliane 혼합물의 자연발화 특성)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.24-30
    • /
    • 2010
  • An accurate information of the autoignition temperature(AIT) is important in developing appropriate prevention and control measures in industrial fire. This study measured the AITs of trichlorosliane and dichlosilane(DCS)-trichlorosliane(TCS) mixtures by using ASTM E659-78 apparatus. The experiment AITs of trichlorosliane, TCS(90wt%)-DCS(10wt%) and the TCS(70wt%)-DCS(30wt%) were $225^{\circ}C,\;250^{\circ}C\;and\;236^{\circ}C$, respectively.

Measurement and Prediction of Autoignition Temperature(AIT) of Flammable Substances - Methanol and Ethanol - (가연성물질의 자연발화온도 측정 및 예측 - 메탄올과 에탄올 -)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.54-60
    • /
    • 2004
  • Flammable substances are frequently used chemical industry processes. An accurate knowledge of the ALTs(Autoignition Temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The AITs are dependent upon many factors, namely initial temperature, pressure, volume, fuel/air stoichiometry, catalyst material, concentration of vapor, ignition delay. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for methanol and ethanol. The A.A.P.E.(Average Absolute Percent Error) and the A.A.D.(Average Absolute Deviation) of the experimental and the calculated delay times by the AITs for methanol were 14.59 and 1.76 respectively. Also the A.A.P.E. and the A.A.D. of the experimental and the calculated delay times by the ATIs for ethanol were 8.33 and 0.88.

The Measurement and Investigation of Fire and Explosion Characteristics of Cyclohexanone (사이클로헥사논의 화재 및 폭발 특성치의 측정 및 고찰)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.28-34
    • /
    • 2011
  • For the safe handling of cyclohexanone, the explosion limits at $25^{\circ}C$ were investigated. The lower flash points and AITs (auto-ignition temperatures) by ignition time delay for cyclohexanone were experimented. By using the literatures data, the lower and upper explosion limits of cyclohexanone recommended 1.1 Vol.% ($100^{\circ}C$) and 9.4 Vol.%, respectively. The lower flash points of cyclohexanone were experimented $42{\sim}43^{\circ}C$ by using closed-cup tester and $49{\sim}51^{\circ}C$ by using open cup tester. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for cyclohexanone and the experimental AIT of cyclohexanone was $415^{\circ}C$.

Measurement of Autoignition Temperature of Ethylbenzene+n-hexanol and Ethylbenzene+n-propionic Acid Systems (Ethylbenzene+n-hexanol 계와 ethylbenzene+n-propionic acid계의 최소자연발화온도의 측정)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.33-40
    • /
    • 2007
  • The values of the AITs(Autoignition temperatures) for fire and explosion protection are normally the lowest reported. This study measured the AITs of ethylbenzene+n-hexanol and ethylbenzene+n-propionic acid Systems from ignition delay time(time lag) by using ASTM E659-78 apparatus. The AITs of ethylbenzene, n-hexanol and n-propionic acid which constituted binary systems were $475^{\circ}C,\;275^{\circ}C\;and\;511^{\circ}C$, respectively. The experimental ignition delay time of ethylbenzene+n-hexanol and ethylbenzene+n-propionic acid systems were a good agreement with the calculated ignition delay time by the proposed equations with a few A.A.D.(average absolute deviation).

Relationship between Autoigniton Temperature(AIT) and Ignition Delay Time for Acids (산(Acid)류의 자연발화온도와 방화지연시간의 관계)

  • 하동명
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.27-33
    • /
    • 2004
  • An accurate knowledge of the AIT(Autoignition temperatures) of chemicals is important in developing appropriate prevention and control measures in industrial fire protection. The AITs describe the minimum temperature to which a substance must be heated, without the application of a flame or spark, which will cause that substance to ignite. The measurement AITs are dependent upon many factors. namely initial temperature. pressure, volume, fuel/air stoichiometry. catalyst material, concentration of vapor, ignition delay time. This study measured the AITs of acids from ignition delay time by using ASTM E659-78 apparatus which was produced in the year 1994. The experiment AITs were a good agreement with the calculated AITs by the proposed equations with a few A.A.P.E.(average absolute percent error) and A.A.D.(average absolute deviation).

Measurement of Autoignition Temperature of o-Xylene+n-pentanol System (오토자일렌과 노말펜탄올 계의 최소자연발화온도 측정)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.66-72
    • /
    • 2006
  • An accurate knowledge of the AITs(autoignition temperatures) is important in developing appropriate prevention and control measures in industrial fire protection. The measurement of AITs are dependent upon many factors, namely initial temperature, pressure, vessel size, fuel/air stoichiometry, catalyst, concentration of vapor, ignition delay time. The values of the AITs used process safety are normally the lowest reported, to provide the greatest margin of sefety. This study measured the AITs of o-xylene+n-pentanol system from ignition delay time by using ASTM E659-78 apparatus. The experimental AITs of o-xylene and n-pentanol were $480^{\circ}C\;and\;285^{\circ}C$, respectively. The experiment AITs of o-xylene+n-pentanol system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D.(average absolute deviation).

Prediction and Measurement of Autoignition Temperature of Toluene and 2-Butanol System (톨루엔과 2-부탄올 계의 최소자연발화온도의 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.73-78
    • /
    • 2015
  • The autoignition temperatures(AIT) of solvent mixture is important index for the safe handling of flammable liquids which constitute the solvent mixtures. Therefore, the AITs of common pure chemical substances are widely reported, but very limited data are available for mixtures. This study, the toluene and 2-butnaol system which used mixture solution solvent was measured the AIT and ignition delay time by using ASTM E659 apparatus. The AITs of toluene and 2-butanol constituted binary system were $547^{\circ}C$ and $400^{\circ}C$, respectively. The experimental AIT of toluene and 2-butanol were a good agreement with the calculated AIT by the proposed equations with a few average absolute deviation(A.A.D.).

Measurement and Investigation of Combustible Properties of n-Heptane for Risk Assessment of Gasoline Tank (가솔린탱크의 위험성평가를 위한 노말헵탄의 연소특성치 측정 및 고찰)

  • Ha, Dong-Myeong;Jeong, Kee-Sin;Lee, Sung-Jin;Cho, Yong-Sun;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.76-81
    • /
    • 2010
  • For the safe handling of n-heptane, the explosion limit at $25^{\circ}C$, the temperature dependence of the explosion limits and the lower flash point were investigated. And AITs (auto-ignition temperatures) by ignition time delay for n-heptane were experimented. By using the literatures data, the lower and upper explosion limits of n-heptane recommended 1.0 Vol% and 7.0 Vol%, respectively. And the lower flash points of n-heptane recommended $-4^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-heptane and the experimental AIT of n-hexane was $225^{\circ}C$. The new equation for predicting the temperature dependence of the explosion limits of n-heptane is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

Measurement of Autoignition Temperature for Toluene + iso-Propanol (IPA) and p-Xylene+n-Butanol Systems (Toluene과 iso-Propanol계 및 p-Xylene과 n-Butanol계의 자연발화온도 측정)

  • Yoon, Yeo-Song;Ha, Dong-Myeong;Yu, Hyun-Sik;Lee, Yong-Soon
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • The values of the AIT (autoignition temperature) for fire and explosion protection are normally the lowest reported. The MAITB (Minimum Autoignition Temperature Behavior) of flammable liquid mixture is exhibited when the AITs of mixture is below the AIT of the individual components. The MAITB is an interesting experimental features, which can be significant from the perspective of industrial fire safety. In this study, the AITs of toluene + iso-propanol(IPA) and p-xylene + n-butanol systems were measured using ASTM E659-78 apparatus. The AITs of toluene, iso-propanol (IPA), pxylene and n-butanol which constituted two binary systems were $547^{\circ}C,\;463^{\circ}C,\;557^{\circ}C$ and $340^{\circ}C$ respectively. The toluene + iso-propanol(IPA) system is exhibited MAITB at 0.3 mole fraction of toluene, and its minimum autoignition temperature was $460^{\circ}C$.

Risk Assessment by Means of Measurement of Combustible Characteristics for n-Nonanol (노말노난올의 연소특성치 측정에 의한 위험성 평가)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.84-89
    • /
    • 2012
  • For the safe handling of n-nonanol, this study was investigated the explosion limits of n-nonanol in the reference data. The flash points and AITs (autoignition temperatures) by ignition delay time were experimented. As a results, the lower and upper explosion limits of n-nonanol recommended 0.8 Vol.% and 6.1 Vol.%, respectively. The lower flash points of n-nonanol by using closed-cup tester were experimented $94{\sim}97^{\circ}C$. The lower flash points of n-nonanol by using open cup tester were experimented $103{\sim}104^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-nonanol. The experimental AIT of n-nonanol was $270^{\circ}C$.