• Title/Summary/Keyword: ASM2.0

Search Result 45, Processing Time 0.02 seconds

Development Plan for the GMT Fast-steering Secondary Mirror

  • Lee, Sugnho;Han, Jeong-Yeol;Park, Chan;Jeong, Ueejeong;Yoon, Yang-noh;Song, Je Heon;Moon, Bongkon;Park, Byeong-Gon;Cho, Myung K.;Dribusch, Christoph;Park, Won Hyun;Jun, Youra;Yang, Ho-Soon;Moon, Il-Kwon;Oh, Chang Jin;Kim, Ho-Sang;Lee, Kyoung-Don;Bernier, Robert;Gardner, Paul;Alongi, Chris;Rakich, Andrew;Dettmann, Lee;Rosenthal, Wylie
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.66.3-67
    • /
    • 2016
  • The Giant Magellan Telescope (GMT) will feature two interchangeable Gregorian secondary mirrors, an adaptive secondary mirror (ASM) and a fast-steering secondary mirror (FSM). The FSM has an effective diameter of 3.2 m and built as seven 1.1 m diameter circular segments, which are conjugated 1:1 to the seven 8.4m segments of the primary. Each FSM segment contains a tip-tilt capability for fine co-alignment of the telescope subapertures and fast guiding to attenuate telescope wind shake and mount control jitter. This tip-tilt capability thus enhances performance of the telescope in the seeing limited observation mode. As the first stage of the FSM development, KASI conducted a Phase 0 study to develop a program plan detailing the design and manufacturing process for the seven FSM segments. The GMTO-KASI team matured this plan via an internal review in May 2016 and the revised plan was further assessed by an external review in June 2016. In this poster, we present the technical aspects of the FSM development plan.

  • PDF

Evaluation of the Usefulness of GDH & Toxin Test for the Diagnosis of Clostridioides difficile in a Tertiary Hospital in Seoul

  • Joo, Ho-Joong;Kim, Sang-Ha;Kwon, Pil-Seung;Ryu, Jae-Ki;Yook, Keun-Dol;Yu, Young-Bin;Kim, Young-Kwon
    • Biomedical Science Letters
    • /
    • v.26 no.3
    • /
    • pp.210-216
    • /
    • 2020
  • The purpose of this study was to evaluate GDH & Toxin (GDT) tests for the identification of the presence of Clostridioides difficile (C. difficile) as well as to detect whether any toxin was present in the feces of patients suspected of diarrhea associated with C. difficile. Data related to the results of toxin and culture (TC) tests and GDT tests conducted on patients with diarrhea and suspected CDI between January 2017 and august 2018, positive test rates, patient ages and sexes, whether the patients were hospitalized, and turnaround time (TAT) were analyzed retrospectively. Of the 7,554 total tests conducted for CDI diagnosis, 1,010 TC tests (14.9%) were positive, while 92 GDT tests (12.0%) were positive. Of these positive cases, 815 (80.7%) identified through TC test and 80 (87%) identified through GDT test were inpatients. also, among the patients with positive test results, 497 (49.2%) diagnosed through TC test and 45 (48.9%) diagnosed through GDT test were aged 61 years or older. The total time required to complete a TC test was 83.6 hours, while the time required for a GDT test was 11.2 hours, equating to an approximately three-day difference between the two tests. The detection of toxin-producing C. difficile is important in CDI diagnosis, but the commonly used Enzymeimmunoassay (EIA) toxin tests with low sensitivity result in delayed CDI diagnosis time. Therefore, primary screening tests for CDI diagnosis using the GDT method and secondary tests using additional methods are considered most effective.

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.

Three-dimensional Model Generation for Active Shape Model Algorithm (능동모양모델 알고리듬을 위한 삼차원 모델생성 기법)

  • Lim, Seong-Jae;Jeong, Yong-Yeon;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.6 s.312
    • /
    • pp.28-35
    • /
    • 2006
  • Statistical models of shape variability based on active shape models (ASMs) have been successfully utilized to perform segmentation and recognition tasks in two-dimensional (2D) images. Three-dimensional (3D) model-based approaches are more promising than 2D approaches since they can bring in more realistic shape constraints for recognizing and delineating the object boundary. For 3D model-based approaches, however, building the 3D shape model from a training set of segmented instances of an object is a major challenge and currently it remains an open problem in building the 3D shape model, one essential step is to generate a point distribution model (PDM). Corresponding landmarks must be selected in all1 training shapes for generating PDM, and manual determination of landmark correspondences is very time-consuming, tedious, and error-prone. In this paper, we propose a novel automatic method for generating 3D statistical shape models. Given a set of training 3D shapes, we generate a 3D model by 1) building the mean shape fro]n the distance transform of the training shapes, 2) utilizing a tetrahedron method for automatically selecting landmarks on the mean shape, and 3) subsequently propagating these landmarks to each training shape via a distance labeling method. In this paper, we investigate the accuracy and compactness of the 3D model for the human liver built from 50 segmented individual CT data sets. The proposed method is very general without such assumptions and can be applied to other data sets.

Juvenile Polyps in Bangladeshi Children and Their Association with Fecal Calprotectin as a Biomarker

  • Das, Subarna Rani;Karim, ASM Bazlul;RukonUzzaman, Md;Mazumder, Md Wahiduzzaman;Alam, Rubaiyat;Benzamin, Md;Marjan, Parisa;Sarker, Mst. Naznin;Akther, Hazera;Mondal, Mohuya
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.52-60
    • /
    • 2022
  • Purpose: Colonoscopy is considered the most reliable method for the diagnosis of juvenile polyps. However, colonoscopic screening is an invasive and expensive procedure. Fecal calprotectin (FCP), a marker of intestinal inflammation, has been shown to be elevated in patients with polyps. Therefore, this study aimed to evaluate FCP as a screening biomarker for the diagnosis of juvenile polyps. Methods: This cross-sectional, observational study was conducted at the Pediatric Gastroenterology and Nutrition Department, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh. For children with polyps, colonoscopic polypectomy and histopathology were performed. FCP levels were analyzed before and 4 weeks after polypectomy in all patients. Information was recorded in a datasheet and analyzed using the computer-based program SPSS. Results: The age of the children was between 2.5 and 12 years. Approximately 93% of the polyps were found in the rectosigmoid region. Children with juvenile polyps had elevated levels of FCP before polypectomy that subsequently normalized after polypectomy. The mean FCP levels before and after polypectomy were 277±247 ㎍/g (range, 80-1,000 ㎍/g) and 48.57±38.23 ㎍/g (range, 29-140 ㎍/g) (p<0.001), respectively. The FCP levels were significantly higher in patients with multiple polyps than in those with single polyps. Moreover, mean FCP levels in patients with single and multiple polyps were 207.6±172.4 ㎍/g and 515.4±320.5 ㎍/g (p<0.001), respectively. Conclusion: Colonic juvenile polyps were found to be associated with elevated levels of FCP that normalized after polypectomy. Therefore, FCP may be recommended as a noninvasive screening biomarker for diagnosis of colonic juvenile polyps.