• Title/Summary/Keyword: ARM PA

Search Result 16, Processing Time 0.026 seconds

Lightweight Capability-Based Access Control System on File Descriptor via ARM PA (ARM PA를 통한 경량화된 파일 디스크립터 권한 관리 시스템)

  • Kyuwon Cho;Hojoon Lee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.319-323
    • /
    • 2023
  • In intra-process isolation, file descriptors work as another attack vector from the memory corruption attacks. The attacker can read or write by corrupting file descriptors so they can escape the isolation. In this paper, we propose new lightweight capability-based access control system on file descriptor using ARM's hardware extension, PA(Pointer Authentication). Our system was implemented on Linux kernel module, only shows 5% overhead to control the access on the file descriptor.

Electroencephalography Relative Alpha Spectrum and Subjective Preference Based on Compression Level of Arm According to Region (상지 부위별 압박수준에 따른 EEG 상대 알파파 스펙트럼과 주관적 선호도 분석)

  • Park, Sunhee;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.2
    • /
    • pp.310-320
    • /
    • 2022
  • This study aimed to ascertain the most efficient level of compression to be applied on a particular area along the upper extremities whilst developing functionality to prevent musculoskeletal disorders among workers who frequently use their arms. The compression areas were divided into upper arm, forearm, and wrist. The compression levels were applied using three types of bands. Comparisons on these bands' usability were based on evaluations of recorded brainwaves and subjective sensation response. Nine men in their twenties were selected for the experiment. The results revealed that when compression was applied, the left and right occipital lobes, plus the parietal lobe, were activated. Also, the alpha wave activity tended to increase, thereby exemplifying the compression's positive effects. The most physiologically efficient and subjectively preferred compression levels were 1.3 and 2.6 kPa for the upper arm and wrist. Furthermore, the compression level at the forearm should be at least 2.0 kPa.

Effects of Pressurization on Finger's Blood Velocity of Tendon and Muscle Areas in Forearm of 20's male (20대 남성의 아래팔 손목 건영역과 근육영역 가압이 손가락 혈류속도에 미치는 효과)

  • Kim, Nam Yim;Hong, Kyunghi
    • Fashion & Textile Research Journal
    • /
    • v.21 no.4
    • /
    • pp.488-496
    • /
    • 2019
  • This study investigated if the proper pressure level on the wrist tendon area and muscle area of the lower arm are within the same range by examining the responses of blood flow and subjective evaluation. Subjects consisted of 18 males in their 20s, and the experimental bands were custom-made by applying size measurements of each subject. In the experiment, a total of 5 steps were selected by reducing 10 (Step 1) to 50 (Step 5)% from the original body size in the circumferential direction. Blood flow was measured with a sensor attached to the tip of the finger inside the right hand while sitting in a chair for 15 minutes. Blood velocity began to increase (0.82 kPa) when the wrist circumference around tendon area was reduced by 20% (Step 2) and reached its maximum (1.72 kPa) at Step 4. However, the preferred subjective pressure was 1.36 kPa, which was less than the maximum pressure value of 1.72 kPa for Step 4. Blood velocity began to increase when pressure on the muscle area was 1.38 kPa and reached its maximum at 2.16 kPa; however, the most preferred clothing pressure was 1.71 kPa. The results of this study showed that the appropriate pressure level was higher in the muscle area than in the wrist tendon of the lower arm and indicated that graduated compression is favorable.

Comparison of Supraspinatus Muscle Architecture During Three Different Shoulder Strengthening Exercises Using Ultrasonography

  • Moon, Il-young;Lim, One-bin;Cynn, Heon-seock;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Background: Strengthening the supraspinatus is an important aspect of a rehabilitation program for subacromial impingement and tendinopathy. Many authors recommended empty-can (EC), full-can (FC), and prone full-can (PFC) exercises to strengthen the supraspinatus. However, no ultrasonography study has yet investigated supraspinatus muscle architecture (muscle thickness; MT, pennation angle; PA, fiber bundle length; FBL) in relation to supraspinatus strengthening exercises. Objects: The purpose of this study was to compare the architecture (MT, PA, and FBL) of the supraspinatus muscle during three different types of exercises (EC, FC, and PFC) using diagnostic ultrasound. Methods: Participants performed three different exercises: (A) EC; the arm was maintained at $60^{\circ}$ abduction with full internal rotation in the sitting position, (B) FC; the arm was maintained at $60^{\circ}$ abduction with full external rotation in the sitting position, and (C) PFC; the arm was maintained at $60^{\circ}$ abduction with full external rotation in the prone position. Ultrasonography was used to measure the MT, PA and FBL of the supraspinatus. One-way repeated analysis of variance with Bonferroni's post-hoc test was used to compare between the three exercises and the initial position of each exercise. Results: Compared with each initial position, the FC exercise showed the greatest mean difference in muscle architecture properties and the PFC exercise showed the least mean difference. Conclusion: The findings suggest that the FC exercise position may have an advantage in increasing the amount of contractile tissue or producing muscle power and the PFC exercise position may be useful in a rehabilitation program because it offers the advantage of maintaining the muscle architecture properties.

Buried Fiber Optic Intrusion Sensor (매설형 광섬유 침입자 센서)

  • Park, Jae-Hee;Kim, Myung-Gyoo;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.1-6
    • /
    • 1996
  • The feasibility of producing a practical buried fiber optic sensor with high sensitivity for detecting intruders is demonstrated. Experiments were carried out with the use of an all fiber Michelson interferometer, the sensing arm of which was buried in sand. When the sensing arm was buried 8 inches deep in sand, the pressure length product required for a half fringe shift in: the sensor output was $1.09\;kPa{\cdot}m$. The relation between the applied weight and the phase change was almost linear. Experimental results indicated that the sensitivity of the optical fiber sensor was sufficient to detect people on foot and vehicles passing over the buried fiber.

  • PDF

Design of a Prototype Jacket for Upper Extremity Load Reduction (상지 부하 감소를 위한 기능성 상의 프로토타입 디자인)

  • Park, Sunhee;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.4
    • /
    • pp.613-623
    • /
    • 2022
  • This study developed a functional prototype jacket designed to reduce loads on the upper extremities of workers performing repetitive motions in the same posture for extended periods of time. Dynamic taping lines were applied to the upper extremities, and three dimensional (3D) supporters were inserted in the abdomen and back waist areas corresponding to the core muscles. Clothing pressure on the upper-extremity dynamic taping lines was set to two levels (proto P1 and proto P2), and the 3D supporters were designed in three types (proto FW, proto FW/BW, proto FW/BW/BBX). According to the subjective pressure perceived on each part of the upper extremities, the level proto P1 pressure was preferred. The proto FW/BW/BBX 3D supporter was rated as excellent, and the perceived pressure was ranked as satisfactory. The prototype jacket performed upper-extremity load reduction when the upper-extremity clothing-pressure level was set to 1.8 kPa, 2.1 kPa, and 2.4 kPa on the upper arm, forearm, and wrist regions, respectively, and when 3D supporters were installed in the abdomen and back of the waist with the addition of a back band.

Short-term Benefits of Mobilization for Patients with Non-Specific Neck Pains: Executive Function and Neck Pain Intensity

  • Choi, Wansuk;Heo, Seoyoon
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.2
    • /
    • pp.1803-1809
    • /
    • 2019
  • Background: Cervical mobilization has been applied mainly for the improvement of arm and neck movements and pain reduction, and little research has been done to improve the executive function. Since this kind of so-called mechanical neck pain is one of most common symptoms, there are controversial issues about this with spine alignment. Posteroanterior (PA) mobilization from the Maitland concept is a process of examination, assessment, and treatment of neuromusculoskeletal disorder by manipulative physical therapy. Objective: To examine the short-term benefits of mobilization for patients with non-specific neck pain. Design: Dual-group Pretest-Posttest Design from the Quasi-Experimental research Methods: Fourteen participants (male 8, female 6; 20's of their age) with non-specific neck pains which are distributed all the unilateral or bilateral body side were recruited. Participants were categorized to Neck Pain with Movement Coordination Impairments (NPMCI) and Neck Pain with Mobility Deficits (NPMD) groups according to the results of physical examination. Professional physical therapist who has over 15-years-of clinical experience applicated manipulative therapy for the neck pain, an occupational therapist only conducted evaluations; K-NDI (Korean version of the Neck Disability Index), VAS (Visual Analog Scale), BDS-K (Korean version of Behavioral Dyscontrol Scale) for decreasing possible adverse effects; there were no person who reported other symptoms followed 4 weeks from the trial. Results: In the NPMCI group, data analysis indicated statistical differences between the PA mobilization interventions in NDI and BDS-K; even though, pain was reduced in VAS, this is not a significantly differ. In the NPMD group, data analysis represented statistical differences between the PA mobilization interventions in NDI, VAS and BDS-K; the scores were represented to be increased or the pain got relief. Conclusions: PA mobilization techniques according to Maitland concept have beneficial effects in patients with neck pain and other clinical positive effects which included neck disability, pain itself and motor function of upper extremity.

A Study on Fiber Optic Hydrophone with Double Interferometers for Optical Path Length Compensation

  • Kim, Jeong-suk;Yoon, Hyun-gyu;Seol, Jae-soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1E
    • /
    • pp.25-30
    • /
    • 2002
  • We report on the development of a fiber optic hydrophone consists of a sensing Michelson interferometer and a compensating Mach-Zehnder interferometer for optical path length compensation. The double interferometer configuration has the following advantages: the hydrophone can be made more small; a laser source with a relatively short coherence length can be used; and the compensating interferometer can be located near the signal processing electronics, far away from the sensing interferometer and noise introduced by reference arm can be greatly reduced. The performance of the hydrophone is evaluated experimentally by immersing the sensing interferometer in a water tank to detect underwater acoustic signals generated by an acoustic wave projector. Experimental results show that over the frequency range of 1 to 4 kHz, the hydrophone has an almost flat response with an average normalized sensitivity of -302 dB re 1/ μ Pa.

A Study of Tube Angle and Patient's Rotation Angle in Scapular Y View (어깨뼈 후전사방향촬영에서 Tube 각도와 환자의 회전각도 관한 연구)

  • Ahn, ByeoungJu;Lee, JunHaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.271-275
    • /
    • 2013
  • Shoulder bone scan everyday life, sports activities at the side of the shoulder joint, or applying strong force in the lateral occurs. Mainly on upper arm abduction, temple, other rotational dislocation of the shoulder joint gahaejyeo as useful for observing the presence or absence of lesions is used. Shoulder PA oblique projection prevent distortion of the image due to the angle and the most useful diagnostic radiological investigate shooting angle. Shoulder blade body and the acromion and coracoid process Y-view is formed characters. $10^{\circ}$ angle between the shoulder blades and the acromion is the obstruction. $20^{\circ}{\sim}25^{\circ}$ to the Y-view of the humerus head looks superimposed, the position of the shoulder joint and seemed appropriate. $35^{\circ}$ of the humerus head superimposed on the Y-view, but above the humerus head and shoulder joints were distorted. When $45^{\circ}$ elevation observed on the side of the best has come Y-view also acromion and coracoid process is finished.

A Study on the Application of Medical Compression Arm Sleeves Using a MRT(Moisture Responded Transformable) Fibers (MRT(Moisture Responded Transformable)섬유의 의료용 압박소매 적용에 관한 연구)

  • Cho, Daehyun;Jung, Taedu;Park, Eunhee;Park, Youngmi
    • Textile Coloration and Finishing
    • /
    • v.33 no.2
    • /
    • pp.87-95
    • /
    • 2021
  • In this study, the application of a medical compression sleeve of Moisture Responded Transformable(MRT) fibers to the treatment of lymphedema after surgery in breast cancer patients was investigated. MRT fibers were manufactured with PET and Nylon6 bi-component cross-section yarns, and compression sleeves of sleeves 1, 2, 3, and 4 were knitted in order of size, and then the physical properties and clinical tests were evaluated. As a result, the pressure of compression sleeve in wrinkle was the lowest in sleeve 1 with 3.81 kPa, and the highest in sleeve 4 with 5.22 kPa. Elastic recovery rate is that all parts except the top of the sleeve 1 exhibited 100%. The air permeability was good at 12.1 ~ 16.1 cm3/cm2/sec, and peeling was also comparatively excellent as grade 3. In addition, the weight of the compression sleeves 1, 2, and 3 decreased as 18.3 ~ 23.0 g/m2 depend on size, while the compared sample was heavier with 17.39 ~ 32.61 g/m2. In lymphoscintigraphy test, it was confirmed that the function of remaining lymph node was good in all patients. Although there were no differences between samples in skin irritation and tightness in wearing comfort, the manufactured sleeves showed better fit, lightness, fashion and breathability than the comparable sleeves.